《UL 69 CRD-2013 UL Standard for Safety Electric-Fence Controllers - Section Paragraph Reference 4 3 1 10 4 36A 40 6 Subject Direct Plug-In Supply Controllers (Edition 10 June 30 200.pdf》由会员分享,可在线阅读,更多相关《UL 69 CRD-2013 UL Standard for Safety Electric-Fence Controllers - Section Paragraph Reference 4 3 1 10 4 36A 40 6 Subject Direct Plug-In Supply Controllers (Edition 10 June 30 200.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): GQYRStandard Number: UL 69Edition Date: June 30, 2009Edition Number: 10Section / Paragraph Reference: 4.3.1, 10.4, 36A, 40.6Subject: Direct Plug-In Supply Co
3、ntrollersDECISION:(new)4.3.1 Direct Plug-In Controller An electric fence controller for indoor use only with a single output whichemploys a blade assembly on the enclosure for connection to the branch circuit. The controller may beprovided with output wiring or wire binding screws intended for conne
4、ction to solid wire. Not considereda direct plug-in power supply that is detachable from the electric fence controller.(new section)10.4 Direct Plug-In Controllers10.4.1 The integral blade assembly of direct plug-in controllers shall comply with the constructionrequirements in the Standard for Attac
5、hment Plugs and Receptacles, UL 498, and Wiring Devices Dimensional Specifications, ANSI/NEMA WD6, for a 125 V, 15 A, 2 pole, 3 wire, grounded typeconfiguration, and shall not be retractable. See 10.4.7 and 10.4.8.Exception: A fence controller complying with Supplement SA for double insulation shall
6、 be provided witha 125 V, 15 A, 2 pole, two wire type configuration.10.4.2 If a direct plug-in controllers employs a manually operated line connected single-pole switch or afuse with an accessible contact, it shall employ a polarized- or grounding-type blade assembly.10.4.3 The maximum acceptable mo
7、ment, center of gravity, dimensions, and weight of a direct plug-incontroller shall comply with the following requirements, see 10.4.4:a) The quotient of WY/Z shall not exceed 48 ounces (1361 g);b) The quotient of WY/S shall not exceed 48 ounces (1361 g);c) The product of WX shall not exceed 80 ounc
8、e-inches (0.56 Nm); andd) The weight of a controller shall not exceed 28 ounces (794 g).Where the definitions for the symbols are as follows:W is the weight of the controller in ounces (g).Y is the distance illustrated in Figure 10.4.1 in inches (mm).UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHE
9、R REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULZ is the lesser of the two distances, Z1 or Z2, as illustrated in Figure 10.4.1 in inches(mm).S is the lesser of the two distances, S1 or S2, as illustrated in Figure 10.4.1 in inches(mm).X is the greater of the two distances, X1 or X2, as illu
10、strated in Figure 10.4.1 in inches(mm).This is generated text for figtxt.STANDARD NUMBER: UL 69 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFigure 10.4.1Dimensions of a direct plug-in controllerSTANDARD NUMBER: UL 69 -3-UL COPYRIGHTED M
11、ATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL10.4.4 The moment and weight specified in 10.4.3 are to be determined as follows:a) For controllers with an output cord, the cord is to be cut off at the enclosure, or at the strain-relief means if the strain-re
12、lief means is outside the enclosure.b) For controllers with directly mounted accessories, the values are to be measured with theaccessories in place.c) An integral tab is not to be included in measurements of the linear dimensions for thepurpose of determining moments unless:1) The tab and enclosure
13、 withstand the impact described in Section 30 with one impacton the tab itself, without deformation; and2) For a polymeric enclosed controller having an integral tab, the tab and enclosure donot distort at temperatures to which the material may be subjected under conditions ofnormal and abnormal use
14、 as determined by the mold stress relief distortion test in theStandard for Polymeric Materials - Use in Electrical Equipment Evaluations, UL 746C.10.4.5 When inserted in a duplex receptacle, no part of a direct plug-in controller, including an integral tabor output wiring, shall interfere with full
15、 insertion of an attachment plug into the adjacent receptacle. SeeFigure 10.4.2.Exception: This requirement does not apply to a controller that renders the adjacent receptacle completelyunusable in any one mounting position.This is generated text for figtxt.STANDARD NUMBER: UL 69 -4-UL COPYRIGHTED M
16、ATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFigure 10.4.2125V, 15A Duplex receptacleSTANDARD NUMBER: UL 69 -5-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL10.4.6 A mounting tab shall not be provi
17、ded with a direct plug-in controller unless all of the followingconditions are met:a) A screw is provided and constructed to secure the mounting tab of the controller to a duplexreceptacle that has a center screw, see Figure 10.4.2;b) For a controller without a grounding pin, the mounting tab is con
18、structed so that thecontroller may be mounted to both grounding and nongrounding receptacles; andc) A mounting tab does not serve as ground.10.4.7 The enclosure of a controller shall be capable of being gripped for removal from the receptacle towhich it is connected, and the perimeter of the face se
19、ction from which the blades project shall not be lessthan 0.20 inch (5.1 mm) from any point on either blade. In order to determine compliance with thisrequirement for controllers with rounded edges, the perimeter of the face section is considered to be thepoint at which the articulate probe is able
20、to access as shown in Figure 10.4.4.10.4.8 With reference to 10.4.7, for an extension from the face for mechanical support of the bladesprovided as shown in Figure 10.4.3, the point of measurement shall be determined by application of thearticulate probe, Figure 10.4.5, as shown in Figure 10.4.4.Thi
21、s is generated text for figtxt.Figure 10.4.3Extension for mechanical support of bladesSTANDARD NUMBER: UL 69 -6-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFigure 10.4.4Determination of perimeter of controllers with rounded edgesSTANDARD N
22、UMBER: UL 69 -7-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFigure 10.4.5Articulate probe with web stopSTANDARD NUMBER: UL 69 -8-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL10.4.
23、9 With reference to 10.4.7, for a direct plug-in controller employing removable blades for the inputconnectors, the measurement shall also be determined on the plug module while removed from the directplug-in controller.10.4.10 The controller shall be provided with the instructions of 40.6.(new sect
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL69CRD2013ULSTANDARDFORSAFETYELECTRICFENCECONTROLLERSSECTIONPARAGRAPHREFERENCE43110436A406SUBJECTDIRECTPLUGINSUPPLYCONTROLLERSEDITION10JUNE30200PDF

链接地址:http://www.mydoc123.com/p-1068820.html