UL 6703-2014 UL Standard for Safety Connectors for Use in Photovoltaic Systems (First Edition Reprint with revisions through and including December 22 2017)《光伏系统用连接器的UL安全标准 (第一版 通过.pdf
《UL 6703-2014 UL Standard for Safety Connectors for Use in Photovoltaic Systems (First Edition Reprint with revisions through and including December 22 2017)《光伏系统用连接器的UL安全标准 (第一版 通过.pdf》由会员分享,可在线阅读,更多相关《UL 6703-2014 UL Standard for Safety Connectors for Use in Photovoltaic Systems (First Edition Reprint with revisions through and including December 22 2017)《光伏系统用连接器的UL安全标准 (第一版 通过.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 6703 Connectors for Use in Photovoltaic SystemsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZE
2、D FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Connectors for Use in Photovoltaic Systems, UL 6703 First Edition, Dated August 28, 2014 Summary of Topics This revision of ANSI/UL 6703 includes clarication of requirements for the Strain Relief Test. T
3、he revised requirements are substantially in accordance with Proposal(s) on this subject dated September 26, 2014. For further information regarding Summary of Requirements, please visit https:/ THIS FIRST EDITION, INCLUDING REVISIONS DATED JANUARY 16, 2015, REPLACES THE OUTLINE OF INVESTIGATION FOR
4、 CONNECTORS FOR USE IN PHOTOVOLTAIC SYSTEMS, UL 6703, AND THE OUTLINE OF INVESTIGATION FOR MULTI-POLE CONNECTORS FOR USE IN PHOTOVOLTAIC SYSTEMS, UL 6703A. AS OF FEBRUARY 29, 2016, OUTLINE UL 6703, THIRD ISSUE AND OUTLINE UL 6703A, FIRST ISSUE WILL BE WITHDRAWN. All rights reserved. No part of this
5、publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but
6、not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inabil
7、ity to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standa
8、rds for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers compute
9、r system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and th
10、at have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. JANUARY 16, 2015 UL 6703 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 16, 2015 UL 6703 tr2 No Text on This Pa
11、geUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL August 28, 2014 (Title Page Reprinted: January 16, 2015) 1 UL 6703 Standard for Connectors for Use in Photovoltaic Systems Prior to the rst edition, the requirements for the products covered
12、by this standard were included in the Outline of Investigation for Connectors for Use in Photovoltaic Systems, UL 6703 and the Outline of Investigation for Multi-Pole Connectors for Use in Photovoltaic Systems, UL 6703A. First Edition August 28, 2014 This ANSI/UL Standard for Safety consists of the
13、First Edition including revisions through January 16, 2015. The most recent designation of ANSI/UL 6703 as an American National Standard (ANSI) occurred on January 16, 2015. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Co
14、mments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor ele
15、ctronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/UL 6703-2015UL COPYRIGHTED MATERIAL NOT AUTHORIZED
16、 FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL AUGUST 28, 2014 CONNECTORS FOR USE IN PHOTOVOLTAIC SYSTEMS - UL 6703 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4
17、2 General 4 2.1 Components .4 2.2 Units of measurement .5 2.3 Undated references .5 3 Glossary .5 CONSTRUCTION 4 General 6 5 Current Carrying Parts (Contacts) .7 6 Polymeric Materials .7 6.1 General .7 6.2 Insulating material 8 6.3 Gaskets, Seals and O rings 9 7 Spacings .9 8 Accessibility of Uninsu
18、lated Live Parts 10 PERFORMANCE 9 PV Connector Tests 11 9.1 General 11 9.2 Effectiveness of Locking and Strain Relief tests .15 9.3 Gasket tests 16 RATINGS 10 Details .17 MARKINGS INSTRUCTIONS 12 Assembly Instructions .18 12.1 Dissemination 18 12.2 Required content .19 12.3 Assembly procedure 20 12.
19、4 Verication 20 APPENDIX A Standards for Components .A1 AUGUST 28, 2014 CONNECTORS FOR USE IN PHOTOVOLTAIC SYSTEMS - UL 6703 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 This standard covers latching or locking t
20、ype PV connectors either as a free connector (separate entity) or as a xed connector (panel or bulkhead type) and rated 1000 V dc or less. These connectors are intended for use in wiring methods detailed in Part IV of Article 690 Solar Photovoltaic Systems of the National Electrical Code, NFPA 70. 1
21、.2 This standard is intended for single polarity PV connectors suitable for use on insulated, stranded copper type USE-2 or Photovoltaic Wire (PV Wire) rated 90C, 105C, 125C, or 150C dry; 90C wet; 600, 1000, or 2000 V. 1.3 This standard also covers latching or locking type multi-pole PV connectors r
22、ated 1000 Vac or dc or less. Multi-pole PV connectors consist of connectors, panel mounted connectors, distribution blocks and splitter connectors for the purpose of facilitating connections to and from inverters and like devices in a PV system. 1.4 This standard is also intended for multi-pole PV c
23、onnectors suitable for use on insulated, stranded copper type TC-ER, USE-2 or Photovoltaic Wire (PV Wire) rated 90C, 105C, 125C, or 150C dry; 90C wet; 600, 1000, or 2000 V. 1.5 This standard covers PV connectors whose dimensions are not dened in any national or international technical standard. Conn
24、ectors are identied and tested with compatible mating part (or parts if multiple exist) and are to be of the same brand, unless multiple product manufacturers are submitting under the same evaluation for the purpose of proving intermatability. 1.6 This standard does not apply to PV wiring harnesses
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL67032014ULSTANDARDFORSAFETYCONNECTORSFORUSEINPHOTOVOLTAICSYSTEMSFIRSTEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGDECEMBER222017

链接地址:http://www.mydoc123.com/p-1068810.html