UL 6703 CRD-2017 UL Standard for Safety Connectors for Use in Photovoltaic Systems - Section Paragraph Reference 3 Glossary 9 Field assembly test and 12 3 2 Field assembly procedu.pdf
《UL 6703 CRD-2017 UL Standard for Safety Connectors for Use in Photovoltaic Systems - Section Paragraph Reference 3 Glossary 9 Field assembly test and 12 3 2 Field assembly procedu.pdf》由会员分享,可在线阅读,更多相关《UL 6703 CRD-2017 UL Standard for Safety Connectors for Use in Photovoltaic Systems - Section Paragraph Reference 3 Glossary 9 Field assembly test and 12 3 2 Field assembly procedu.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): QIJQ, QIFAStandard Number: UL 6703Standard Title: Standard for Connectors for Use in Photovoltaic SystemsEdition Date: August 28, 2014Edition Number: 1Section / Paragraph Reference: 3 Glossary, 9 Fiel
3、d assembly test, and 12.3.2 Fieldassembly procedureSubject: Add additional requirements for field assembled PV connectorsDECISION:3 Glossary3.x FACTORY ASSEMBLED CONNECTOR A connector that is intended to be assembled andterminated to the cable under controlled conditions at a manufacturers location.
4、3.y FIELD ASSEMBLED CONNECTOR A connector that is intended to be assembled and terminatedto the cable in the field.8A Field Assembled Connectors8A.1 For field assembled connectors, the manufacturer shall provide all connector components, and anyspecial or nonstandard tools if required for installati
5、on of the connector to the cable in the field. FieldAssembled connectors shall also be provided with assembly instructions in accordance with Section 12.PERFORMANCE9 PV Connector Tests9.4 Field assembly test9.4.1 Samples of field assembled connectors shall be subjected to an installation test. The a
6、ssembly shallbe performed with the connector components and any special or nonstandand tools as provided by themanufacturer. The installation shall be performed precisely according to the manufacturers assemblyinstructions.9.4.2 All tests required by this standard shall be conducted on samples assem
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL6703CRD2017ULSTANDARDFORSAFETYCONNECTORSFORUSEINPHOTOVOLTAICSYSTEMSSECTIONPARAGRAPHREFERENCE3GLOSSARY9FIELDASSEMBLYTESTAND1232FIELDASSEMBLYPROCEDUPDF

链接地址:http://www.mydoc123.com/p-1068809.html