《UL 62 CRD-2016 UL Standard for Safety Flexible Cords and Cables - Section Paragraph Reference 4 1 4 1 1 5 1 7 5 1 8 1 5 1 10 1 5 1 20 5 1 20 1 5 1 21 1 Tables 2 23 44 46 47 49 Sub.pdf》由会员分享,可在线阅读,更多相关《UL 62 CRD-2016 UL Standard for Safety Flexible Cords and Cables - Section Paragraph Reference 4 1 4 1 1 5 1 7 5 1 8 1 5 1 10 1 5 1 20 5 1 20 1 5 1 21 1 Tables 2 23 44 46 47 49 Sub.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUL LLC CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(s); however, it is curre
2、ntly not part of the UL Standard(s) referencedbelow.Product Category (CCN): ZJCZStandard Number: UL 62Standard Title: Standard for Flexible Cords and CablesEdition Date: March 14, 2014Edition Number: 19Section / Paragraph Reference: 4.1.4.1.1, 5.1.7, 5.1.8.1, 5.1.10.1, 5.1.20, 5.1.20.1,5.1.21.1, Tab
3、les, 2, 23, 44, 46, 47, 49Subject: Addition of Type YXTWuDECISION:4.1.4 Conductor assembly4.1.4.1 Lay of conductors4.1.4.1.1 Flexible cords with cabled conductors shall have the individual conductors twisted together witha length of lay not greater than that shown in Table 10. When cords covered in
4、Table 10 have mixedconductor sizes, the lay shall be based on the number of conductors and the largest conductor size foundin the cord. Constructions not covered in Table 10 shall have the individual conductors laid up so that thelay shall be not more than 15 times the overall diameter of the conduc
5、tor assembly. For CXTWu, YXTWu,CXWTc, and TXc, the lay shall not be more than 30 times the overall diameter of the insulated conductor.For multiple-layer cords, the conductors in each layer shall be twisted, but the lay is not specified, exceptthat in the outer layer the lay shall be not more than 1
6、5 times the overall diameter of that layer.4.1.4.1.2 Length of lay shall be determined in accordance with the test, Length of Lay (coveredcomponents), in CAN/CSA-C22.2 No. 2556, UL 2556, or NMX-J-516-ANCE.5.1.7 Weather resistance - all W cords and electric vehicle cablesAfter conditioning for 720 h
7、in a xenon arc weatherometer as described in the test, Weather (sunlight)resistant, in CAN/CSA-C22.2 No. 2556, UL 2556, or NMX-J-553-ANCE, the insulation on a specimen ofthe individual conductor of Types CXWTc, YXTWuand CXTWuand on finished Types PXWTc, SPT-1Wc,u,SPT-2Wc,u, and XTWuand the jacket of
8、 other Type W cords shall:(a) Show no cracks when wound one complete turn around a mandrel having a diameter asshown in Table 43 while at a temperature of -30C 1C for a period of 1 h. During the bending,the conditioned surface shall be opposite the surface contacting the mandrel. The specimenshall b
9、e allowed to rest 16 h to 96 h at room temperature before conducting the cold bend test.(b) Retain an average tensile strength and elongation of not less than 80%. Conditioned andunaged sets (five specimens each) shall be allowed to rest 16 h to 96 h at room temperature,followed by physical properti
10、es testing. Conditioned surfaces required to be diecut shall not bebuffed or skived away.5.1.8 Heat-shock resistance5.1.8.1 PVC and TPE insulationsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULThe insulation shall show no cracks when specime
11、ns of finished unjacketed cords and specimens of theindividual conductors from jacketed cords and Types CXWTc, CXTWu, YXTWuand TXcare exposed to atemperature of 121C 2C for all temperature ratings of PVC and TPE rated at 60C, or 150C 2C forTPE rated in excess of 60C, for 1 h while wound six close tu
12、rns around a mandrel having a diameter asshown in Table 44. The specimen shall show no cracks when unwound from the mandrel after cooling toroom temperature.5.1.10 Tightness of insulation test5.1.10.1 The insulation of Types CXWTcand,CXTWuand YXTWushall be applied tightly to reduceslipping of the co
13、nductor in the insulation when each conductor is subjected to the procedure outlined inClause 5.1.10.2. The insulation on parallel cords other than Type TPT, shaver cordsu, NISPm,u, NISPEm,u,or NISPT cords shall be applied tightly to reduce slipping of the insulation when subjected to theprocedure o
14、utlined in Clause 5.1.10.3.5.1.10.2 Following the method described in Clause 5.1.10.4 and with the 1.81 kg (4 lb) weight andspecimen thus suspended for a period of 30 s, slipping of the conductor, separator, or combination thereofshall not exceed 3 mm (0.11 in). Measurement shall be made at the top
15、of the specimen at the point atwhich the bare conductor enters the insulation.5.1.10.3 Following the method described in Clause 5.1.10.4 and with the 3.63 kg (8 lb) weight andspecimen thus suspended for a period of 30 s, slipping of either single conductor, separator, orcombination thereof shall not
16、 exceed 3 mm (0.11 in). Measurement shall be determined from the pointwhere the conductor is cut off even with the insulation.5.1.10.4 Compliance with Clauses 5.1.10.2 and 5.1.10.3 shall be determined in accordance with the test,Tightness of insulation, in CAN/CSA-C22.2 No. 2556, UL 2556, or NMX-J-5
17、56-ANCE.5.1.20 Abrasion test for Types XTWuand CXTWu, YXTWu5.1.20.1 GeneralThe insulation on the 22 AWG size of Types XTWuand CXTWuwire and of the straightened individualconductors from finished Type CXTWucord shall not wear through to expose the conductor or conductorsin 400 or fewer cycles on any
18、of the specimens. The insulation on an YXTW wire shall not wear throughto expose the conductor in 600 or fewer cycles on any of the specimens.5.1.21.1 GeneralNo more than half the strands in any conductor in the 22 AWG size of Types XTWuand CXTWucord andwire shall be broken by 6000 cycles of the fle
19、xing. No more than half the strands in any conductor of aType YXTWuwire shall be broken by 9000 cycles of the flexing.5.1.21.5 ExaminationFollowing the completion of the 6000 appropriate number of cycles of flexing, the weights shall beremoved from the specimens. The wire or cord shall be cut open a
20、t the points of flexure against the twofixed rods and the number of broken strands counted in each conductor.STANDARD NUMBER: UL 62 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable 2Stranding(See Clauses 4.1.1.7.1 and 4.4.1.2.)Cord or
21、cable type Conductor size*Diameter of individual wiresMinimum Maximummm (in) mm (in)SPT-0m0.325 mm2(22AWG)0.125 (0.0049) 0.260 (0.010)CXTWu, XTWu0.325 mm2(22AWG)0.079 (0.0031) 0.165 (0.0065)YXTWu0.519 mm2(20AWG) and 18AWG)0.125 (0.0049) 0.260 (0.010)SP-1m,u*, SP-2u, SPT-1*, SPT-2,SPT-1Wc,u, SPT-2Wc,
22、u, SVT, SVTO, SVTOO, SV, SVO,SVOO, HPN, HSJ, HSJO, HSJOW, HSJOO, HSJOOW,HPDu, SPE-1u*, SPE-2u, SVEu, SVEOu, SVEOOu, NISP-1m,u, NISP-2m,u, NISPT-1, NISPT-2, NISPE-1m,u, NISPE-2m,u, clockuAll sizes 0.125* (0.0049)* 0.165(0.0065)0.260* (0.010*)SJ, SJT, SJTO, SJTOO, SJO, SJOO, SJOW, SJOOW, S,SO, SOO, SO
23、W, SOOW, SJTW, SJTOW, SJTOOW, ST,STO, STOO, STW, STOW, STOOW, SP-3m,u, SPT-3,PXWTc, CXWTc, SJEu, SJEWu, SJEOu, SJEOWu, SJEOOu,SJEOOWu,SEu, SEWu, SEOu, SEOWu, SEOOu, SEOOWu,SPE-3u, EVJ, EVJEm,u, EVJT, EV, EVEm,u, EVT2.63 mm2(13AWG) and smaller0.125 (0.0049) 0.260 (0.010)3.31 33.6 mm2(12 2 AWG)0.125 (
24、0.0049) 0.410(0.016)E, EO, ETT, ETP All sizes 0.125 (0.0049) 0.260 (0.010)CXTWu, XTWu20 18 AWG 0.125 (0.0049) 0.260 (0.010)PXTc,TXc0.325 mm2(22AWG) and 0.519mm2(20 AWG)0.125 (0.0049) 0.260 (0.010)EV, EVEm,u, EVT 1 2/0 AWG Minimum 133 strands, stranded size notspecified3/0 AWG 500kcmilMinimum 259 str
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL62CRD2016ULSTANDARDFORSAFETYFLEXIBLECORDSANDCABLESSECTIONPARAGRAPHREFERENCE4141151751815110151205120151211TABLES22344464749SUBPDF

链接地址:http://www.mydoc123.com/p-1068712.html