UL 62 CRD-2015 UL Standard for Safety Flexible Cords and Cables - Section Paragraph Reference 4 1 1 7 2 7 (new) 5 1 24 (new) 5 1 25 (new) 6 2 4 (i & j) (new) Tables 1 3 C 7 23 41 .pdf
《UL 62 CRD-2015 UL Standard for Safety Flexible Cords and Cables - Section Paragraph Reference 4 1 1 7 2 7 (new) 5 1 24 (new) 5 1 25 (new) 6 2 4 (i & j) (new) Tables 1 3 C 7 23 41 .pdf》由会员分享,可在线阅读,更多相关《UL 62 CRD-2015 UL Standard for Safety Flexible Cords and Cables - Section Paragraph Reference 4 1 1 7 2 7 (new) 5 1 24 (new) 5 1 25 (new) 6 2 4 (i & j) (new) Tables 1 3 C 7 23 41 .pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): ZJCZStandard Number: UL 62Standard Title: Standard for Flexible Cords and CablesEdition Date: May 14, 2014Edition Number: 19Section / Paragraph Reference: 4.
3、1.1.8.2A (new), 4.1.1.8.3, 4.1.1.8.3A (new), Table XX(new)Subject: Grounding Conductor SizesDECISION:4.1.1.8.2 For flexible cord or cable with conductor sizes 5.26 mm2(10 AWG) and smaller, the groundingconductor shall be the same size or larger than the largest circuit conductors, except for Type DR
4、Tc,where a 3.31 mm2(12 AWG) grounding conductor may be used with 5.26 mm2(10 AWG) circuitconductors4.1.1.8.2A For flexible cord or cable with conductor sizes 6.63 mm2(9 AWG), the grounding conductorshall be 5.26 mm2(10 AWG).4.1.1.8.3 For flexible cord or cable with conductor sizes 8.37 33.6 mm2(8 2
5、AWG) and larger, thereduction of the grounding conductor by not more than two AWG sizes from the largest ungrounded circuitconductor shall be permitted (e.g., a cord having an 8.37 mm2(8 AWG) ungrounded circuit conductor mayhave a minimum 5.26 mm2(10 AWG) grounding conductor).4.1.1.8.3A For Electric
6、 vehicle cables with conductor sizes larger than 33.6 mm2(2 AWG), the groundingconductor shall not be smaller than indicated in Table XX and may be sectioned.Table XXCircuit conductor size, mm2(AWG) Minimum grounding conductor size, mm2(AWG)42.4 67.4 (1 2/0) 13.3 (6)85.0 127 (3/0 250) 21.3 (4)152 20
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL62CRD2015ULSTANDARDFORSAFETYFLEXIBLECORDSANDCABLESSECTIONPARAGRAPHREFERENCE411727NEW5124NEW5125NEW624IJNEWTABLES13C72341PDF

链接地址:http://www.mydoc123.com/p-1068711.html