UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗拱形门和模板》.pdf
《UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗拱形门和模板》.pdf》由会员分享,可在线阅读,更多相关《UL 608-2004 UL Standard for Safety Burglary Resistant Vault Doors and Modular Panels (Seventh Edition Reprint with Revisions Through and Including June 5 2017)《防盗拱形门和模板》.pdf(19页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 608 Burglary Resistant Vault Doors and Modular PanelsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUT
2、HORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Burglary Resistant Vault Doors and Modular Panels, UL 608 Seventh Edition, Dated November 30, 2004 Summary of Topics Revised 8.3.1 to show that door frame constructions, vestibules, and the like, n
3、eed to provide equivalent security protection as the vault door and connecting vault panel structures. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line in the
4、 margin and are followed by an effective date note indicating the date of publication or the date on which the changed requirement becomes effective. The revised requirements are substantially in accordance with Proposal(s) on this subject dated June 3, 2011. All rights reserved. No part of this pub
5、lication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not
6、 limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability
7、 to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards
8、 for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer s
9、ystem. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that
10、have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. The following table lists the future effective dates with the corresponding reference. MAY 31, 2012 UL 608 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBU
11、TION WITHOUT PERMISSION FROM UL Future Effective Dates References The effective date for the revised requirement is to be determined. 8.3.1 MAY 31, 2012 UL 608 tr2UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 30, 2004 (Title Page
12、Reprinted: May 31, 2012) 1 UL 608 Standard for Burglary Resistant Vault Doors and Modular Panels The rst and second editions were titled Burglary Resistant Vault Doors. First Edition April, 1980 Second Edition January, 1982 Third Edition July, 1982 Fourth Edition August, 1988 Fifth Edition September
13、, 1994 Sixth Edition March, 1999 Seventh Edition November 30, 2004 This ANSI/UL Standard for Safety consists of the Seventh Edition including revisions through May 31, 2012. The most recent designation of ANSI/UL 608 as an American National Standard (ANSI) occurred on May 31, 2012. ANSI approval for
14、 a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards D
15、evelopment System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property
16、 of UL. COPYRIGHT 2012 UNDERWRITERS LABORATORIES INC. ANSI/UL 608-2012UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 30, 2004 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 2 No Text on This PageUL COPYRIGHTED MATERIAL
17、NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 General 5 2.1 Components .5 2.2 Units of measurement .6 2.3 Undated references .6 3 Glossary .6 CONSTRUCTION 4 Corrosion Protection .7 5 Locks 7 PERFORMANCE 6 General 8 7 Test Equipm
18、ent .8 8 Attack Tests 8 8.1 General .8 8.2 Lock mechanism .9 8.3 Cutting an opening .9 8.4 Cutting locking bolts 9 MARKING 9 Details .9 APPENDIX A Standards for Components .A1 NOVEMBER 30, 2004 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FUR
19、THER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 31, 2012 BURGLARY RESISTANT VAULT DOORS AND MODULAR PANELS - UL 608 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover vault doo
20、rs and vault modular panels (for use in the construction of vault oors, walls, and ceilings) of the type intended for use in nancial institutions, commercial, industrial and mercantile properties, and the like, and that are relied upon to protect the contents from burglary attack. 1.2 These requirem
21、ents are intended to establish the burglary resistant rating of vault doors and modular panels according to the length of time they withstand attack by common mechanical tools, electric tools, cutting torches, or any combination of these means. The ratings based on the net working time to effect ent
22、ry are as follows: a) Class M 1/4 hour. b) Class 1 1/2 hour. c) Class21hour. d) Class32hours. 1.3 These requirements do not cover attacks with the burning bar (thermal lance) or explosives. 2 General 2.1 Components 2.1.1 Except as indicated in 2.1.2, a component of a product covered by this standard
23、 shall comply with the requirements for that component. See Appendix A for a list of standards covering components used in the products covered by this standard. 2.1.2 A component is not required to comply with a specic requirement that: a) Involves a feature or characteristic not required in the ap
24、plication of the component in the product covered by this standard, or b) Is superseded by a requirement in this standard. 2.1.3 A component shall be used in accordance with its rating established for the intended conditions of use. 2.1.4 Specic components are incomplete in construction features or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL6082004ULSTANDARDFORSAFETYBURGLARYRESISTANTVAULTDOORSANDMODULARPANELSSEVENTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGJUNE52017

链接地址:http://www.mydoc123.com/p-1068577.html