《UL 60730-2-9 (ND)-2010 National Differences For UL 60730-2-9 Standard for Automatic Electrical Controls for Household and Similar Use - Part 2-9 Particular Requirements for Tempera.pdf》由会员分享,可在线阅读,更多相关《UL 60730-2-9 (ND)-2010 National Differences For UL 60730-2-9 Standard for Automatic Electrical Controls for Household and Similar Use - Part 2-9 Particular Requirements for Tempera.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60730-2-9Standard for Automatic Electrical Controls for Household and Similar Use - Part 2-9: ParticularRequirements for Temperature Sensing ControlsUL COPYRIGHTED MATE
2、RIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60730-2-9Standard for Automatic Electrical Controls for Household and Similar Use - Part 2-9: ParticularRequirements for Temperature Sensing ControlsEdition: 3Edition Date: October 13, 20
3、10These revisions are being issued to adopt the requirements covered by Amendment No. 1 of IEC60730-2-9 and to adopt the North American National Differences to this IEC Amendment.THE STANDARDS TECHNICAL PANEL FOR UL 60730-2-9 HAS DETERMINED THAT AS OFOCTOBER 19, 2018, THE FIRST EDITION OF UL 60730-2
4、-9 AND THE TWELFTH EDITION OF UL873 WILL BE WITHDRAWN AND MAY BE USED TO DETERMINE A NEWLY SUBMITTEDPRODUCTS COMPLIANCE UNTIL THIS DATE.This document provides a single listing of the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of thi
5、s publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,includ
6、ing but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or
7、theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electro
8、nic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on
9、 the purchasers computer system.Copyright 2013 Underwriters Laboratories Inc.AUGUST 16, 2013NATIONAL DIFFERENCES FOR UL UL 60730-2-92UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technica
10、l National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify national difference type, andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1
11、 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These are deviations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting
12、 the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will not be deleted until a particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on edi
13、torial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the national difference entails. Typically one of thefollowing words is used to explain how the text of the national difference is to be appl
14、ied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,figure, or annex. Addition is not meant to include adding select words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subc
15、lause,table, figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as theaddition, replacement or deletion of certain words or the replacement of an entire clause,subclause, table, figure, or annex of the base IEC text.
16、AUGUST 16, 2013 NATIONAL DIFFERENCES FOR UL UL 60730-2-9 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1.1.101DV D2 Modify text of 1.1.101 with the following:This standard applies to single operation devices, thermostats
17、 for drip-type coffee makers,self-heating thermal protectors (SHTP) for recessed lighting fixtures, and Fan/Heatsequencers as defined in this standard.2.2.107ADV D2 Add the following definitions to Clause 2.2 of the Part 2:2.2.107ADV.1 Thermostats for Drip-Type Coffee Makers an automatic thermostat(
18、operating control with type 2 action) intended for use in household Drip-Type CoffeeMakers.2.2.107ADV.2 Set-Point Temperature Rating (Ts-p) for thermostats for use in drip-typeCoffee Makers The temperature at which the thermostats electrical load switchingcontacts change state upon temperature rise.
19、 For adjustable thermostats the Set-PointTemperature Rating (Ts-p) is the temperature at which the thermostats electrical loadswitching contacts change state, upon temperature rise, with the thermostat adjusted tothe maximum temperature setting. This rated value is a nominal figure of a temperaturer
20、ange. The range is defined by the allowable tolerances specified in table 7.22.2.107ADV.3 Operating Temperature Initial (Top-init) for thermostats for use in drip-typeCoffee Makers A temperature, measured during the deviation test, at which thethermostats electrical load switching contacts change st
21、ate upon temperature rise. Ifmultiple trials of the deviation test are conducted, this value is the arithmetic average ofup to three trials.2.2.107ADV.4 Operating Temperature Final (Top-fin) for thermostats for use in drip-typeCoffee Makers A temperature, measured during the drift test conducted aft
22、er theendurance test sequence, at which the thermostats electrical load switching contactschange state upon temperature rise. If multiple trials of the final drift test are conducted,this value is the arithmetic average of up to three trials.2.2.107ADV.5 Maximum Normal Use Temperature Rating (Tmax)
23、for thermostats for use indrip-type Coffee Makers The maximum temperature permitted on the thermostatssensing surface during normal operation of the coffee maker. This temperature is equalto or greater than Ts-p.2.2.107ADV.6 Maximum Dry Operation Temperature Rating (Tdry) for thermostats for usein d
24、rip-type Coffee Makers The maximum temperature permitted on the thermostatssensing surface during abnormal (dry) operation of the coffee maker. This temperature isequal to or greater than Tmax.2.2.107ADV.7 Reset Temperature (Treset) for thermostats for use in drip-type CoffeeMakers A temperature at
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL6073029ND2010NATIONALDIFFERENCESFORUL6073029STANDARDFORAUTOMATICELECTRICALCONTROLSFORHOUSEHOLDANDSIMILARUSEPART29PARTICULARREQUIREMENTSFORTEMPERAPDF

链接地址:http://www.mydoc123.com/p-1068511.html