UL 60335-2-3 (ND)-2004 National Differences For UL 60335-2-3 Standard for Safety of Household and Similar Electrical Appliances Part 2 Particular Requirements for Electric Irons (Fn.pdf
《UL 60335-2-3 (ND)-2004 National Differences For UL 60335-2-3 Standard for Safety of Household and Similar Electrical Appliances Part 2 Particular Requirements for Electric Irons (Fn.pdf》由会员分享,可在线阅读,更多相关《UL 60335-2-3 (ND)-2004 National Differences For UL 60335-2-3 Standard for Safety of Household and Similar Electrical Appliances Part 2 Particular Requirements for Electric Irons (Fn.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60335-2-3Standard for Safety of Household and Similar Electrical Appliances, Part 2: ParticularRequirements for Electric IronsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR
2、 FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60335-2-3Standard for Safety of Household and Similar Electrical Appliances, Part 2: Particular Requirements forElectric IronsEdition: 5Edition Date: July 14, 2004Revisions dated February 26, 2013 were issued t
3、o reflect the latest approval date as anAmerican National Standard and to incorporate the following changes in requirements: Update to UL 60335-2-3 to align it with the 5th edition of UL 60335-1 issued October 31,2012.UL 60335-2-3 is an adoption of IEC 60335-2-3, Safety Standard for Household and Si
4、milarElectrical Appliances, Part 2: Particular Requirements for Electric Irons, (Edition 5.2, Issued bythe IEC July 2008). Please note that the national difference document incorporates all of the U.S.national differences for UL 60335-2-3.This document provides a single listing of the National Diffe
5、rences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwisewithout prior permission of UL.UL
6、provides this standards document as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be liable for any special, incidental, consequential, indirect or similar damages,in
7、cluding loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possibility of such damage. In no event shall ULs liability for any damage ever exc
8、eed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonableattorneys fee
9、s) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright 2013 Underwriters Laboratories Inc.FEBRUARY 26, 2013NATIONAL DIFFERENCES FOR UL UL 60335-2-32UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTIO
10、N ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the notations indicated below to identify national difference type, andthes
11、e types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise safety for U.S. consumers and users of products.D2 - These are deviations
12、 based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations based on the component standards and will not be deleted until a particul
13、arcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national difference contains a description of what the national difference entails. Typ
14、ically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,figure, or annex. Addition is not meant to include adding select words to the
15、base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause,table, figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the existing base IEC text such as theaddition, replacement or deletion of cert
16、ain words or the replacement of an entire clause,subclause, table, figure, or annex of the base IEC text.FEBRUARY 26, 2013 NATIONAL DIFFERENCES FOR UL UL 60335-2-3 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1DV.1 D1 M
17、odification of 1DV.1 of the UL part 1:The articulate probe of figure 12DV shall replace the test finger of figure 1 for theseproducts.1DV.2 D2 Modification to add the following to the second paragraph of Clause 1 of thepart 2:These requirements apply to electric irons and CORDLESS IRONS rated 250 V
18、or less. Theseirons are intended to be employed in accordance with the National Electrical Code,ANSI/NFPA 70. Annex DVD of Part 1 provides examples of and references for regulatoryrequirements that may apply to appliances.1DV.3 D2 Add the following to Note 101 of the part 2: additional requirements
19、applicable to equipment intended for use in hazardous locations as definedin the National Electrical Code, ANSI/NFPA 70, are not included in the standard.1DV.4 D2 Add the following to Note 102 of the part 2: ironing machines, ironing presses, or other garment finishing appliances that are covered by
20、 theStandard for Garment Finishing Appliances, UL 141.1.101DV D2 Addition to the part 2:Values stated without parentheses are the requirement. Values in parentheses areexplanatory or approximate information.3.108DV D2 Addition of the following definition to the part 2:AUTOMATIC IRON: An iron having
21、some form of automatic temperature control, usually athermostatic control, that operates automatically within predetermined temperature limitsto open and close the circuit through the heating element.7.8DV D2 National Difference Deleted7.12DV D2 Modification to add the following to 7.12 of the part
22、2:Unless a conflict exists as a result of the application of an instruction item to a specificproduct, the text of the instructions shall be as shown or the equivalent. The items are notrequired to be numbered. The headings READ ALL INSTRUCTIONS BEFORE USING andSAVE THESE INSTRUCTIONS shall be first
23、 and last respectively in the list of items. Otherimportant safety instruction items required by the manufacturer may be included.IMPORTANT SAFETY INSTRUCTIONSWhen using an iron, basic precautions should always be followed, including the following:FEBRUARY 26, 2013NATIONAL DIFFERENCES FOR UL UL 6033
24、5-2-34UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULREAD ALL INSTRUCTIONS BEFORE USING1. Only use an iron for its intended use.2. To avoid the risk of electric shock, do not immerse the iron in water or otherliquids.3. Always turn the iron O
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL6033523ND2004NATIONALDIFFERENCESFORUL6033523STANDARDFORSAFETYOFHOUSEHOLDANDSIMILARELECTRICALAPPLIANCESPART2PARTICULARREQUIREMENTSFORELECTRICIRONSFNPDF

链接地址:http://www.mydoc123.com/p-1068400.html