UL 60335-2-24 CRD-2018 UL Standard for Saftey Household and Similar Electrical Appliances - Safety - Part 2-24 Particular Requirements for Refrigerating Appliances Ice-Cream Appliar.pdf
《UL 60335-2-24 CRD-2018 UL Standard for Saftey Household and Similar Electrical Appliances - Safety - Part 2-24 Particular Requirements for Refrigerating Appliances Ice-Cream Appliar.pdf》由会员分享,可在线阅读,更多相关《UL 60335-2-24 CRD-2018 UL Standard for Saftey Household and Similar Electrical Appliances - Safety - Part 2-24 Particular Requirements for Refrigerating Appliances Ice-Cream Appliar.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): SHZZ, SHMRStandard Number: UL 60335-2-24Standard Title: Standard for Household and Similar Electrical Appliances - Safety -Part 2-24: Particular Requirements for Refrigerating Appliances, Ice-CreamApp
3、liances and Ice-MakersEdition Date: April 28, 2017Edition Number: 2Section / Paragraph Reference: 22.118DVSubject: Refrigerant Tubing ProtectionDECISION:22.118DV D2 Addition of Clauses 22.118DV.1 and 22.118DV.2 to the Part 2:22.118DV.1 Compression-type appliances which use flammable refrigerants sha
4、ll not be constructed withrefrigerant tubing on the exterior of the refrigerator such that it could be grasped or handled during movingof the appliance.Refrigerant tubing on a refrigerator employing a flammable refrigerant shall be protectedor enclosed to avoid mechanical damage and damage that coul
5、d occur during moving of the product.22.118DV.1.1 Refrigerant tubing located within the confines of the cabinet and tubing that does notprotrude from the compressor compartment is considered to be protected from mechanical damage.22.118DV.1.2 A static condenser coil mounted on the outside of a refri
6、gerator is considered to beprotected against mechanical damage if it complies with all of the following:- The return bends of the condenser are covered such that they cannot be grasped or handledduring moving of the product. The return bends are considered to be adequately covered if theycannot be g
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL60335224CRD2018ULSTANDARDFORSAFTEYHOUSEHOLDANDSIMILARELECTRICALAPPLIANCESSAFETYPART224PARTICULARREQUIREMENTSFORREFRIGERATINGAPPLIANCESICECREAMAPPLIARPDF

链接地址:http://www.mydoc123.com/p-1068396.html