UL 60335-2-24 CRD-2017 UL Standard for Saftey Household and Similar Electrical Appliances C Safety C Part 2-24 Particular Requirements for Refrigerating Appliances Ice-Cream Appliar.pdf
《UL 60335-2-24 CRD-2017 UL Standard for Saftey Household and Similar Electrical Appliances C Safety C Part 2-24 Particular Requirements for Refrigerating Appliances Ice-Cream Appliar.pdf》由会员分享,可在线阅读,更多相关《UL 60335-2-24 CRD-2017 UL Standard for Saftey Household and Similar Electrical Appliances C Safety C Part 2-24 Particular Requirements for Refrigerating Appliances Ice-Cream Appliar.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): SHZZ, SHMRStandard Number: UL 60335-2-24Standard Title: Standard for Household and Similar Electrical Appliances Safety Part 2-24: Particular Requirements for Refrigerating Appliances, Ice-CreamApplia
3、nces and Ice-MakersEdition Date: April 28, 2017Edition Number: 2Section / Paragraph Reference: 20.2DV.2, Annexes 101.DVA, 101.DVFSubject: Articulate (Child) Probe Dimensions and TolerancesDECISION:20.2DV.2 D1 Modification of Clause 20.2 of the Part 1 to add the following after the fourthparagraph:Fo
4、r openings with a minor dimension equal to or greater than 34,9 mm (1-3/8 in), compliance shallbe checked by inspection and by applying the test probes of Annex 101.DVA with a force of 11,1N (2,5 lb). The probes shall be rotated or angled to any possible position before, during, or afterinsertion th
5、rough the opening, and if necessary, the probe configuration shall be changed after theprobe has been inserted through the opening. See Annex 101.DVFThis is generated text for figtxt.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFigure 101.D
6、VA.1 Articulate probe with flat and cone shaped hand 3.5 4.5 year ageItem Dimension description Dimensionmm (in)A Middle finger length, 95 percentile 55 (2,2)B Middle finger diameter, 5 percentile 9,1 (0,36)C Hand length, 95 percentile 125 (5)D Elbow to wrist length, 95 percentile 165 (6)E Wrist dia
7、meter (circumference divided by pi), 5 percentile 32 (1,3)F Forearm diameter (circumference divided by pi), 5 percentile 46 (1,8)G Minimum hand CLEARANCE (cone shaped hand part), 5 percentile 39,1 (1,54)H Cone shaped part at finger attachment 20 (0,79)I Hand breadth (flat hand part), 5 percentile 48
8、 (1,9)J Wrist breadth (used for the hand thickness flat hand part), 5 percentile 24 (0,9)K Hand breadth at finger attachment (flat hand part) 36 (1,4)L Upper arm length, 95 percentile a aNotes:1 The probes were designed with a center pin to rotate the hand with respect to the lower arm. That motion
9、can beequivalently represented by rotating the probe.2 The finger tip is developed to match the dimensions of the UL articulated probe. The diameter from the tip to the firstjoint then tapers from the tip dimensions to the finger diameter. The joints are spaced equally along the finger length.3 The
10、probe is designed to permit the hand to bend with respect to the arm using a hinge pin located 6 mm (0,24 in)from the hand length (wrist end) and the hand is restricted in bending not more than 90 with respect to the arm.aIf the upper arm is required to evaluate a part it shall consist of a flexible
11、 tube attached at the end of the lower arm, asthe exact position of the elbow cannot be readily determined from the data points chosen.STANDARD NUMBER: UL 60335-2-24 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULFigure 101.DVA.2 Articulat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL60335224CRD2017ULSTANDARDFORSAFTEYHOUSEHOLDANDSIMILARELECTRICALAPPLIANCESCSAFETYCPART224PARTICULARREQUIREMENTSFORREFRIGERATINGAPPLIANCESICECREAMAPPLIARPDF

链接地址:http://www.mydoc123.com/p-1068395.html