《UL 60079-5 (ND)-2009 National Differences For UL 60079-5 Explosive Atmospheres - Part 5 Equipment protection by powder filling q (Third Edition Reprint with revisions through and i.pdf》由会员分享,可在线阅读,更多相关《UL 60079-5 (ND)-2009 National Differences For UL 60079-5 Explosive Atmospheres - Part 5 Equipment protection by powder filling q (Third Edition Reprint with revisions through and i.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences ForUL 60079-5Explosive Atmospheres - Part 5: Equipment protection by powder filling qUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PE
2、RMISSION FROM ULNational Differences ForUL 60079-5Explosive Atmospheres - Part 5: Equipment protection by powder filling qEdition: 3Edition Date: July 24, 2009This revision to ANSI/UL 60079-5 is being issued to update the title page to reflect thereaffirmation of ANSI approval. No changes in require
3、ments have been made.As noted in the Commitment for Amendments statement located on the back side of the titlepage, UL and ISA are committed to updating this bi-national standard jointly. However, therevision pages dated November 22, 2013 will not be issued by ISA as revision pages but as anupdate t
4、o their standard.This document provides a single listing of the National Differences included in the UL adoption ofthe corresponding IEC standard.All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, ortransmitted in any form by any means, electronic, mech
5、anical photocopying, recording, or otherwisewithout prior permission of UL.UL provides this standards document as is without warranty of any kind, either expressed or implied,including but not limited to, the implied warranties of merchantability or fitness for any purpose.In no event will UL be lia
6、ble for any special, incidental, consequential, indirect or similar damages,including loss of profits, lost savings, loss of data, or any other damages arising out of the use of or theinability to use this standards document, even if UL or an authorized UL representative has been advisedof the possi
7、bility of such damage. In no event shall ULs liability for any damage ever exceed the pricepaid for this standards document, regardless of the form of the claim.Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold ULharmless from and against any loss, exp
8、ense, liability, damage, claim, or judgment (including reasonableattorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronicStandard on the purchasers computer system.Copyright Underwriters Laboratories Inc.NOVEMBER 22, 2013NATIONAL DIFFERENCES FOR UL UL
9、 60079-52UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULPrefaceThis document provides a single listing of the technical National Differences included in the UL adoptionof the corresponding IEC standard.In its IEC-based standards, UL uses the
10、notations indicated below to identify national difference type, andthese types are additionally noted in this document. The standard may not use all types of thesedeviations.D1 - These are deviations which are based on basic safety principles and requirements, elimination ofwhich would compromise sa
11、fety for U.S. consumers and users of products.D2 - These are deviations based on safety practices. These are deviations for IEC requirements that maybe acceptable, but adopting the IEC requirements would require considerable retesting or redesign on themanufacturers part.DC - These are deviations ba
12、sed on the component standards and will not be deleted until a particularcomponent standard is harmonized with the IEC component standard.DE - These are deviations based on editorial comments or corrections.DR - These are deviations based on the national regulatory requirements.Each national differe
13、nce contains a description of what the national difference entails. Typically one of thefollowing words is used to explain how the text of the national difference is to be applied to the base IECtext:Addition / Add - An addition entails adding a complete new numbered clause, subclause, table,figure,
14、 or annex. Addition is not meant to include adding select words to the base IEC text.Deletion / Delete - A deletion entails complete deletion of an entire numbered clause, subclause,table, figure, or annex without any replacement text.Modification / Modify - A modification is an altering of the exis
15、ting base IEC text such as theaddition, replacement or deletion of certain words or the replacement of an entire clause,subclause, table, figure, or annex of the base IEC text.NOVEMBER 22, 2013 NATIONAL DIFFERENCES FOR UL UL 60079-5 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
16、DISTRIBUTION WITHOUT PERMISSION FROM ULNational Differences1DV.1 DR Modification of Clause 1 first paragraph as follows:1DV.1.1 Replace “part of IEC 60079” with “standard”.1DV.2 DR Addition of 1DV.2.1 and 1DV.2.21DV.2.1 The U.S. version of IEC 60079-5 does not include requirements for Group Ielectri
17、cal apparatus. Requirements for Group I electrical apparatus included in thisdocument are to be considered omitted in all instances where they appear.1DV.2.2 Where references are made to IEC 60079 standards, the referenced requirementsfound in these standards shall apply as modified by any applicabl
18、e U.S. NationalDifferences.2DV.1 DR Modification of Clause 2 title to replace as follows:Delete “Normative”.2DV.2 DR Modification of Clause 2 to replace with the following references:IEC 60529,Degrees of protection provided by enclosures (IP Code)ISO 3310-1,Test sieves Technical requirements and tes
19、ting Part 1: Test sieves of metal wire clothISO 3310-2,Test sieves Technical requirements and testing Part 2: Test sieves of perforated platesISO 2591-1,Test sieving Methods using test sieves of woven wire cloth and perforated metal plateUL 2225,Cables and Cable-Fittings for Use in Hazardous (Classi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL600795ND2009NATIONALDIFFERENCESFORUL600795EXPLOSIVEATMOSPHERESPART5EQUIPMENTPROTECTIONBYPOWDERFILLINGQTHIRDEDITIONREPRINTWITHREVISIONSTHROUGHANDIPDF

链接地址:http://www.mydoc123.com/p-1068374.html