UL 51-2013 UL Standard for Safety Power-Operated Pumps and Bypass Valves for Anhydrous Ammonia LP-Gas and Propylene (Tenth Edition Reprint with Revisions Through and Including May .pdf
《UL 51-2013 UL Standard for Safety Power-Operated Pumps and Bypass Valves for Anhydrous Ammonia LP-Gas and Propylene (Tenth Edition Reprint with Revisions Through and Including May .pdf》由会员分享,可在线阅读,更多相关《UL 51-2013 UL Standard for Safety Power-Operated Pumps and Bypass Valves for Anhydrous Ammonia LP-Gas and Propylene (Tenth Edition Reprint with Revisions Through and Including May .pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 51 Power-Operated Pumps and Bypass Valves for Anhydrous Ammonia, LP-Gas, and PropyleneUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM
2、ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Power-Operated Pumps and Bypass Valves for Anhydrous Ammonia, LP-Gas, and Propylene, UL 51 Tenth Edition, Dated May 31, 2013 Summary of Topics This revision of ANSI
3、/UL 51 is being issued to revise the pressure marking in 25.2. The effective date for UL LLC will be announced through Industry File Review Announcement Letter. The revised requirements are substantially in accordance with Proposal(s) on this subject dated January 16, 2015. Text that has been change
4、d in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or
5、otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequent
6、ial, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liabili
7、ty for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reas
8、onable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. MAY 18, 2015 UL 51 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 18, 2015 U
9、L 51 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL May 31, 2013 (Title Page Reprinted: May 18, 2015) 1 UL 51 Standard for Power-Operated Pumps and Bypass Valves for Anhydrous Ammonia, LP-Gas, and Propylene The rst e
10、dition was titled Power-Operated Pumps for LP-Gas. The second, third, and fourth editions were titled Pumps for Anhydrous Ammonia and LP-Gas. The fth, sixth, seventh, eighth, and ninth editions were titled Power-Operated Pumps for Anhydrous Ammonia and LP-Gas. First Edition March, 1956 Second Editio
11、n September, 1959 Third Edition November, 1969 Fourth Edition September, 1972 Fifth Edition September, 1974 Sixth Edition March, 1980 Seventh Edition October, 1992 Eighth Edition November, 1995 Ninth Edition November, 2002 Tenth Edition May 31, 2013 This ANSI/UL Standard for Safety consists of the t
12、enth edition including revisions through May 18, 2015. The most recent designation of ANSI/UL 51 as an American National Standard (ANSI) occurred on May 18, 2015. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or p
13、roposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic cop
14、y of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC. ANSI/UL 51-2015UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER
15、REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 31, 2013 UL 51 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Components 6 3 Units of Measurement .6 4 Undated References 7
16、 5 Glossary .7 CONSTRUCTION 6 Assembly 7 7 Materials .8 8 Bodies, Covers, and Heads .10 9 Strainers 10 10 Springs 11 11 Pumps and Bypass Valves Pressure Ratings 11 12 Relief Valves .11 13 Guards 12 14 Pipe Connections .12 PERFORMANCE 15 General 12 16 Deformation Test .13 17 Leakage Test 13 18 Endura
17、nce Test 14 19 Differential Pressure Test 14 20 Hydrostatic Strength Test 15 21 Moist Ammonia Air Stress Cracking Test 15 22 Tests for Synthetic Rubber Parts .16 22.1 General .16 22.2 Volume change test 16 22.3 Weight loss test 17 23 Comparative Corrosion Tests 18 23.1 General .18 23.2 Tests in the
18、presence of salt spray (fog) 18 23.3 Tests in the presence of moist hydrogen sulde-air mixture .18 23.4 Tests in the presence of moist sulfur dioxide-carbon dioxide-air mixture .19 MANUFACTURING AND PRODUCTION TESTS 24 General 19 MARKINGS 25 Details .20 INSTALLATION AND OPERATING INSTRUCTIONS 26 Det
19、ails .21 MAY 31, 2013 UL 51 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APPENDIX A Standards for ComponentsA1 MAY 31, 2013 UL 51 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL
20、 INTRODUCTION 1 Scope 1.1 These requirements cover power-operated pumps and bypass valves for use in liquid transfer operations in non-refrigerated systems in installations for: a) Anhydrous ammonia systems installed in accordance with the Safety Requirements for the Storage and Handling of Anhydrou
21、s Ammonia, CGA/GAS G-2.1 (ANSI K61.1); b) Liqueed petroleum gas (LP-Gas) systems installed in accordance with the Liqueed Petroleum Gas Code, NFPA No. 58; and c) Propylene systems. 1.2 These requirements do not cover: a) Pumps or compressors intended for handling anhydrous ammonia or LP-Gas or propy
22、lene in the gaseous phase and b) Pumps, compressors or bypass valves for anhydrous ammonia, LP-Gas, or propylene for use in chemical, petro-chemical, petroleum, or utility power plants; nor pipeline or marine terminals; nor related storage facilities at such plants or terminals. 1.3 Equipment covere
23、d by these requirements is for use with LP-Gas, propylene, or anhydrous ammonia as covered by the Standards and Codes in 1.1 and shall have a minimum service pressure rating in accordance with Table 1.1. Exception: A pump without an integral bypass valve with a higher differential pressure obtained
24、in the Differential Pressure Test, Section 17, is permitted to have a lower minimum service pressure rating if it is marked in accordance with 25.2. Table 1.1 Minimum service pressure for rating pumps and bypass valves Maximum differential pressure produced when subjected to the Differential Pressur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL512013ULSTANDARDFORSAFETYPOWEROPERATEDPUMPSANDBYPASSVALVESFORANHYDROUSAMMONIALPGASANDPROPYLENETENTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGMAYPDF

链接地址:http://www.mydoc123.com/p-1068277.html