UL 508 CRD-2007 UL Standard for Safety Industrial Control Equipment - Section Paragraph Reference Exception to par 39 3 (Edition 17 January 28 1999)《工业控制设备的UL安全标准 节 段落参考 第39 3段例外情况.pdf
《UL 508 CRD-2007 UL Standard for Safety Industrial Control Equipment - Section Paragraph Reference Exception to par 39 3 (Edition 17 January 28 1999)《工业控制设备的UL安全标准 节 段落参考 第39 3段例外情况.pdf》由会员分享,可在线阅读,更多相关《UL 508 CRD-2007 UL Standard for Safety Industrial Control Equipment - Section Paragraph Reference Exception to par 39 3 (Edition 17 January 28 1999)《工业控制设备的UL安全标准 节 段落参考 第39 3段例外情况.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories (UL). Itis normative for the applicable
2、UL Product Certification Program(s); however, it is currently not part ofthe UL Standard(s) referenced below.Product Category (CCN): NIMX, EOXT, NISD, NJOT, NKCR, NKHJ, NKPZ, NLDX,NLRV, NMFT, NMTR, NRAQ, NRGF, NRKH, NRNT, SWIV2Standard Number: UL 508Edition Date: : January 28, 1999Edition Number: 17
3、Section / Paragraph Reference: Exception to par. 39.3DECISION:Paragraph 39.3 and its exception is as follows:39.3 The clearance and creepage distance at field wiring terminals shall be in accordance with therequirements in Spacings, Section 36.Exception: If the design of the field wiring terminals i
4、s such that it will preclude the possibility of reducedspacing due to stray strands or improper wiring installation, clearances and creepage distances at the fieldwiring terminal may be evaluated in accordance with the Standard for Insulation Coordination includingClearances and Creepage Distances f
5、or Electrical Equipment, UL 840.The following information should be used when determining if the terminals “will preclude the possibility ofreduced spacing due to stray strands or improper wiring installation”:1) Terminals which are rated for solid wire only comply with this requirement2) Terminals
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL508CRD2007ULSTANDARDFORSAFETYINDUSTRIALCONTROLEQUIPMENTSECTIONPARAGRAPHREFERENCEEXCEPTIONTOPAR393EDITION17JANUARY281999

链接地址:http://www.mydoc123.com/p-1068253.html