《UL 507 CRD-2010 UL Standard for Safety Electric Fans - Section Paragraph Reference Section 14 Subject -R Cord Requirements and Commercial or Industrial Fans (Edition 9 December 13.pdf》由会员分享,可在线阅读,更多相关《UL 507 CRD-2010 UL Standard for Safety Electric Fans - Section Paragraph Reference Section 14 Subject -R Cord Requirements and Commercial or Industrial Fans (Edition 9 December 13.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): GPWVStandard Number: UL 507Edition Date: December 13, 1999Edition Number: 9Section / Paragraph Reference: Section 62.5.9Subject: Markings for Wall and Ceilin
3、g Insert Fans Polymeric HousingsDECISION:62.5.8 A wall or ceiling insert fan or ceiling insert fan/light combination that is provided with a polymerichousing shall be marked, FOR USE IN NON FIRE RATED INSTALLATIONS ONLY. This marking shallbe permanent in letters not less than 2.4 mm (3/32 inch) high
4、, shall be located such that it is visible duringinstallation, and shall be in a contrasting color from the material to which it is applied.62.5.9 A wall or ceiling insert fan or ceiling insert fan/light combination that is provided with a polymerichousing shall be marked, FOR USE IN ONE- AND TWO-FA
5、MILY DWELLINGS ONLY or “NOT FORUSE IN ENVIRONMENTAL AIR-HANDLING SPACES.” This marking shall be permanent in letters notless than 2.4 mm (3/32 inch) high, shall be located such that it is visible during installation and inspectionof wire connections, shall be located near the supply connections, and
6、 shall be in a contrasting color fromthe material to which it is applied.RATIONALE FOR DECISION:The markings required by UL 507 for wall and ceiling insert fans, employing polymeric housing, wereupdated in 2003 to align with the requirements for recessed luminaires in UL 1598, the Standard forLumina
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL507CRD2010ULSTANDARDFORSAFETYELECTRICFANSSECTIONPARAGRAPHREFERENCESECTION14SUBJECTRCORDREQUIREMENTSANDCOMMERCIALORINDUSTRIALFANSEDITION9DECEMBER13PDF

链接地址:http://www.mydoc123.com/p-1068244.html