UL 498 CRD-2014 UL Standard for Safety Attachment Plugs and Receptacles - Section Paragraph Reference (New ) Supplement SH Subject MAGNETICALLY COUPLED CORD CONNECTOR AND INLET (E.pdf
《UL 498 CRD-2014 UL Standard for Safety Attachment Plugs and Receptacles - Section Paragraph Reference (New ) Supplement SH Subject MAGNETICALLY COUPLED CORD CONNECTOR AND INLET (E.pdf》由会员分享,可在线阅读,更多相关《UL 498 CRD-2014 UL Standard for Safety Attachment Plugs and Receptacles - Section Paragraph Reference (New ) Supplement SH Subject MAGNETICALLY COUPLED CORD CONNECTOR AND INLET (E.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): AXUT, RTRTStandard Number: UL 498Standard Title: Standard for Attachment Plugs and ReceptaclesEdition Date: March 30, 2012Edition Number: 15Section / Paragra
3、ph Reference: (New ) Supplement SHSubject: MAGNETICALLY COUPLED CORD CONNECTOR AND INLETDECISION:Addition of new requirements to UL 498 the Standard for Attachment Plugs and Receptacles, SupplementSH Magnetically Coupled Cord connector and Inlet.SUPPLEMENT SH MAGNETICALLY COUPLED CORD CONNECTOR AND
4、INLET :INTRODUCTIONSH1 ScopeSH1.1 The requirements of this supplement cover a magnetically coupled cord connector and inletintended to facilitate the extension of a branch circuit for use with a motor vehicle engine block heater orother electrical utilization equipment, in accordance with the Nation
5、al Electrical Code, NFPA 70.SH1.2 These devices are intended for use with copper conductors only.SH1.3 These devices are only intended for use on 15- or 20-Ampere, 125-V AC only branch circuits.SH2 GlossarySH2.1 For the purpose of this supplement, the following definitions apply.SH2.2 MAGNETICALLY C
6、OUPLED CORD CONNECTOR - A female contact device to be wired onflexible cord for use as an extension from an outlet to make a detachable electrical connection.Connection to inlet is held by a permanent magnet.SH2.3 MAGNETICALLY COUPLED INLET - A male contact device to be wired on flexible cord to pro
7、videan integral blade configuration for the connection of a cord connector. Connection to cord connector isheld by a permanent magnet.SH2.4 MAGNETICALLY COUPLED CONNECTOR ASSEMBLY Devices constructed of two matedhalves (i.e. cord connector and inlet) held together by a permanent magnetSH2.5 OMNIPOLA
8、R IC SWITCH (Hall or Reed Switch) - A hall or reed IC switch that operates with thedetection of a magnetic field.CONSTRUCTIONUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSH3 GeneralSH3.1 In addition to the construction, performance and mark
9、ing requirements contained in this Standard,a magnetically coupled cord connector and inlet shall also comply with the applicable requirements for itsindividual parts as described in Sections SH3.2 SH11.1.SH3.2 The magnetically coupled cord connector assembly shall be constructed so that voltage,amp
10、erage, device configuration and polarity are consistent throughout the complete assembly.SH3.3 A magnetically coupled connector assembly shall have only one outlet supplied from one set of lineblades.SH4 Electrical RatingSH 4.1 A magnetically coupled cord connector assembly shall be rated either 15
11、A, 125 V AC or 20 A,125 V AC only.SH5 Accessibility of Live PartsSH5.1 Accessibility of live parts shall comply with UL 498 para. 9.1.4 in both the coupled and uncoupledpositions. Magnetically coupled connector assembly shall not be relied upon to provide and render parts“de-energized”.Exception: Pe
12、rmanent magnets used in combination with electronic circuitry may be used to render parts“de-energized” provided such electronic circuitry complies with the Standard for Safety-Related ControlsEmploying Solid-State Devices, UL 991. If the computational investigation is conducted, the maximumfailure
13、rate (l) shall not exceed 1.5 failures per million hours. If the demonstrated method is conducted,the test acceleration multiplier shall be 5763.SH6 Environmental ProtectionSH6.1 A magnetically coupled cord connector assembly shall be marked with a Type designation andcomply with the one of the Type
14、 designation identified in UL 498 Supplement SB Enclosure Types forEnvironmental Protection.SH6.2 A magnetically coupled cord connector assembly that is provided with a spring-closing cover shallalso comply with the Spring-Closing Cycling test as described in SH10.SH7 Internal Splices and Connection
15、sSH7.1Internal splices and connections shall be mechanically secure and shall provide electrical continuitywithout strain on connections and terminals.SH7.2 A soldered connection shall be made mechanically secure before being soldered.PERFORMANCESH8 GeneralSH8.1 A magnetically coupled cord connector
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL498CRD2014ULSTANDARDFORSAFETYATTACHMENTPLUGSANDRECEPTACLESSECTIONPARAGRAPHREFERENCENEWSUPPLEMENTSHSUBJECTMAGNETICALLYCOUPLEDCORDCONNECTORANDINLETEPDF

链接地址:http://www.mydoc123.com/p-1068226.html