UL 365-2018 UL Standard for Safety Police Station Connected Burglar Alarm Units and Systems (Fifth Edition).pdf
《UL 365-2018 UL Standard for Safety Police Station Connected Burglar Alarm Units and Systems (Fifth Edition).pdf》由会员分享,可在线阅读,更多相关《UL 365-2018 UL Standard for Safety Police Station Connected Burglar Alarm Units and Systems (Fifth Edition).pdf(143页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 365 Police Station Connected Burglar Alarm Units and Systems STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL C
2、OPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Police Station Connected Burglar Alarm Units and Systems, UL 365 Fifth Edition, Dated January 31, 2018 Summary of Topics The Fifth Edition of the Standard for Police Stat
3、ion Connected Burglar Alarm Units and Systems, UL 365, was issued to expand media to include website. The revised requirements are substantially in accordance with Proposal(s) on this subject dated October 23, 2015. All rights reserved. No part of this publication may be reproduced, stored in a retr
4、ieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merch
5、antability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an auth
6、orized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and
7、hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. JANUARY 31, 2018 UL 365 tr1UL COPYRIG
8、HTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 31, 2018 UL 365 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 31, 2018 1 UL 365 Standard for Police St
9、ation Connected Burglar Alarm Units and Systems First Edition March, 1975 Second Edition July, 1982 Third Edition June, 1993 Fourth Edition July, 1997 Fifth Edition January 31, 2018 This ANSI/UL Standard for Safety consists of the Fifth Edition. The most recent designation of ANSI/UL 365 as an Ameri
10、can National Standard (ANSI) occurred on January 31, 2018. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, and Title Page. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal
11、 Request in ULs On-Line Collaborative Standards Development System (CSDS) at https:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Stan
12、dards shall remain the sole and exclusive property of UL. COPYRIGHT 2018 UNDERWRITERS LABORATORIES INC. ANSI/UL 365-2018UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 31, 2018 POLICE STATION CONNECTED BURGLAR ALARM UNITS AND SYSTEMS
13、 - UL 365 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .9 2 Terminology .10 3 Components 10 4 Units of Measurement 10 5 Undated References .10 6 Glossary 11 7 Installation and Operating
14、Instructions 13 8 Installation and Operating Instructions Physical Media14 CONSTRUCTION ASSEMBLY 9 General.15 9.1 Product assembly .15 9.2 Electrical protection 15 10 Protection of Service Personnel 20 11 Enclosures .20 11.1 General .20 11.2 Doors and covers 22 11.3 Enclosure openings 22 11.4 Screen
15、s and expanded metal 24 11.5 Cast metal.24 11.6 Sheet metal .25 11.7 Product enclosure mounting .28 11.8 Polymeric materials.28 12 Electric Shock 29 13 Corrosion Protection 29 FIELD WIRING CONNECTIONS 14 General30 15 Cord-Connected Products .30 16 Permanently-Connected Products.31 16.1 General .31 1
16、6.2 Field-wiring terminals .32 16.3 Field wiring leads.34 16.4 Polarity identication 35 17 Grounding .35 INTERNAL WIRING 18 General36 19 Wiring Methods.37 20 Separation of Circuits .38 21 Bonding for Grounding 38 JANUARY 31, 2018 POLICE STATION CONNECTED BURGLAR ALARM UNITS AND SYSTEMS - UL 365 3UL
17、COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL COMPONENTS, ELECTRICAL 22 General41 22.1 Mounting of components 41 22.2 Insulating materials .42 22.3 Fuseholders .43 22.4 Current-carrying parts.43 22.5 Power-on indicator .43 23 Overcurrent Prot
18、ection 44 24 Semiconductors 44 25 Switches.44 26 Transformers and Coils44 SPACINGS 27 General44 28 Components .47 PERFORMANCE ALL UNITS 29 General47 29.1 Test units and data .47 29.2 Test samples and miscellaneous data 48 29.3 Test voltages 48 29.4 FCC requirements 48 30 Normal Operation Test 48 31
19、Current Protection Test 49 32 Input Test49 33 Output Measurement Test .49 34 Electrical Supervision Test .50 35 Undervoltage Operation Test .51 36 Overvoltage Operation Test 51 37 Variable Ambient Test .51 38 Humidity Test 52 39 Leakage Current Tests for Cord-Connected Products .52 40 Electric Shock
20、 Current Test 55 41 Overload Test 59 41.1 General .59 41.2 Separately energized circuits 60 42 Endurance Test 60 42.1 General .60 42.2 Separately energized circuits 60 43 Jarring Test 60 44 Dielectric Voltage-Withstand Test .61 45 Temperature Test.62 46 Abnormal Operation Test 66 47 Electrical Trans
21、ient Tests 66 47.1 General .66 47.2 Supply line transients .66 47.3 Internally induced transients .69 47.4 Input/output circuit transients 69 48 AC Induction Test.70 49 Polymeric Materials Test.71 JANUARY 31, 2018 POLICE STATION CONNECTED BURGLAR ALARM UNITS AND SYSTEMS - UL 365 4UL COPYRIGHTED MATE
22、RIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 50 Battery Replacement Test .71 51 Drop Test 72 52 Strain Relief Test .72 52.1 Supply cord .72 52.2 Field-wiring leads.72 53 Ignition Through Bottom-Panel Openings Test73 53.1 General .73 53.2 Hot, aming oil .73
23、53.3 Molten PVC and copper.74 54 Mechanical Strength Tests for Enclosures .74 55 Special Terminal Assemblies Tests .75 55.1 General .75 55.2 Disconnection and reconnection .75 55.3 Flexing test 75 55.4 Millivolt drop test .76 55.5 Temperature test .76 POLICE STATION RECEIVING AND TRANSMITTING UNITS
24、56 General76 57 Common Requirements .77 58 Direct-Connected Units 77 59 Transmitter-Connected Units .77 60 Other Methods of Alarm Transmission.79 61 Standard Line Security Equipment 79 62 Encrypted Line Security Equipment .81 PROTECTED PREMISES EQUIPMENT 63 Subscribers Control Units .81 64 Outside A
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL3652018ULSTANDARDFORSAFETYPOLICESTATIONCONNECTEDBURGLARALARMUNITSANDSYSTEMSFIFTHEDITIONPDF

链接地址:http://www.mydoc123.com/p-1068095.html