UL 347-2016 UL Standard for Safety Medium-Voltage AC Contactors Controllers and Control Centers (Sixth Edition)《中压交流电接触器 控制器和控制中心安全性标准》 (2).pdf
《UL 347-2016 UL Standard for Safety Medium-Voltage AC Contactors Controllers and Control Centers (Sixth Edition)《中压交流电接触器 控制器和控制中心安全性标准》 (2).pdf》由会员分享,可在线阅读,更多相关《UL 347-2016 UL Standard for Safety Medium-Voltage AC Contactors Controllers and Control Centers (Sixth Edition)《中压交流电接触器 控制器和控制中心安全性标准》 (2).pdf(133页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 347 Medium-Voltage AC Contactors, Controllers, and Control Centers STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM
2、ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Medium-Voltage AC Contactors, Controllers, and Control Centers, UL 347 Sixth Edition, Dated January 29, 2016 Summary of Topics The Sixth Edition of the Standard for
3、 Medium-Voltage AC Contactors, Controllers, and Control Centers, UL 347 has been issued to reect the latest ANSI approval date, and to incorporate the proposals dated June 20, 2014 and May 15, 2015. The new and revised requirements are substantially in accordance with Proposal(s) on this subject dat
4、ed June 20, 2014 and May 15, 2015. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is w
5、ithout warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, lo
6、ss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless
7、of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced whi
8、le purchaser is storing an electronic Standard on the purchasers computer system. JANUARY 29, 2016 UL 347 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 29, 2016 UL 347 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZ
9、ED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Association of Standardization and Certication NMX-J-564/106-ANCE Second Edition CSA Group CSA C22.2 No. 253-16 Second Edition Underwriters Laboratories Inc. UL 347 Sixth Edition Medium-Voltage AC Contactors, Controllers, and Con
10、trol Centers JANUARY 29, 2016 ANSI/UL 347-2016UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Commitment for Amendments This standard is issued jointly by the Association of Standardization and Certication (ANCE), the Canadian Standards Asso
11、ciation (operating as “CSA Group”), and Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any part of the standard may be submitted to ANCE, CSA Group, or UL at any time. Revisions to this standard will be made only after processing according to the standards development pr
12、ocedures of ANCE, CSA Group, and UL. CSA Group and UL will issue revisions to this standard by means of a new edition or revised or additional pages bearing their date of issue. ANCE will incorporate the same revisions into a new edition of the standard bearing the same date of issue as the CSA Grou
13、p and UL pages. Copyright 2016 ANCE Rights reserved in favour of ANCE. ISBN 978-1-77139-155-9 2016 CSA Group All rights reserved. No part of this publication may be reproduced in any form whatsoever without the prior permission of the publisher. This Standard is subject to review ve years from the d
14、ate of publication, and suggestions for its improvement will be referred to the appropriate committee. To submit a proposal for change, please send the following information to inquirescsagroup.org and include Proposal for change in the subject line: Standard designation (number); relevant clause, t
15、able, and/or gure number; wording of the proposed change; and rationale for the change. To purchase CSA Group Standards and related publications, visit CSA Groups Online Store at www.shop.csa.ca or call toll-free 1-800-463-6727 or 416-747-4044. Copyright 2016 Underwriters Laboratories Inc. ULs Stand
16、ards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. This ANSI/UL Standard for Safety cons
17、ists of the Sixth Edition. The most recent designation of ANSI/UL 347-2016 as an American National Standard (ANSI) occurred on January 29, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page (front and back), or the Preface. Comments or proposals for rev
18、isions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. To purchase UL Standards, visit Comm 2000 at http:/m- or call toll-free 1-888-853-3503.UL COPYRIGHTE
19、D MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface .6 1 General 8 1.1 Scope and object .8 1.2 Normative references, component standards, and general requirements 8 2 Normal and Special Service Conditions 9 2.1 Normal service conditions .9 2
20、.2 Special service conditions 10 3 Denitions 10 3.1 General terms .10 3.2 Assemblies of controlgear 13 3.3 Parts of assemblies 13 3.4 Switching devices .13 3.5 Parts of a controller 15 3.6 Operation 16 3.7 Characteristic quantities 17 3.101 Fuses 21 3.203 Index of denitions 22 4 Controller and Contr
21、ol Center Ratings and Characteristics 25 4.1 Rated maximum voltage (U r )25 4.2 Rated insulation level (U d ), (U p ) .26 4.3 Rated frequency (f r ) .26 4.4 Rated continuous current and temperature rise .26 4.5 Rated short-time withstand current (I k ) .27 4.6 Rated peak and momentary withstand curr
22、ent 27 4.7 Rated duration of short-circuit (t k ) .28 4.8 Rated supply voltage of operating devices and of auxiliary and control circuits (U a ) . . .29 4.9 Rated supply frequency of closing and opening devices and of control circuits .29 4.10 Rated pressure of compressed gas supply for installation
23、 and/or operation 29 4.101 Rated operational current or rated operational power (I e ).29 4.102 Rated duties 30 4.103 Rated making and breaking capacities .30 4.104 Utilization category 30 4.105 Mechanical endurance (standard and optional) .30 4.106 Electrical endurance .30 4.107 Coordination with m
24、edium-voltage fuses .30 4.108 Types and characteristics of automatic change-over devices and automatic acceleration control devices 31 4.109 Types and characteristics of autotransformers or reactors 31 4.110 Types and characteristics of the starting resistors for rheostatic motor starters 31 4.111 C
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL3472016ULSTANDARDFORSAFETYMEDIUMVOLTAGEACCONTACTORSCONTROLLERSANDCONTROLCENTERSSIXTHEDITION 交流电 接触器

链接地址:http://www.mydoc123.com/p-1068086.html