UL 2572 CRD-2014 UL Standard for Safety Mass Notification Systems - Section Paragraph Reference Sections 75 and 76 Subject Performance tests for High Power Speaker Arrays (Edition .pdf
《UL 2572 CRD-2014 UL Standard for Safety Mass Notification Systems - Section Paragraph Reference Sections 75 and 76 Subject Performance tests for High Power Speaker Arrays (Edition .pdf》由会员分享,可在线阅读,更多相关《UL 2572 CRD-2014 UL Standard for Safety Mass Notification Systems - Section Paragraph Reference Sections 75 and 76 Subject Performance tests for High Power Speaker Arrays (Edition .pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): PGWMStandard Number: UL 2572Standard Title: Standard for Mass Notification SystemsEdition Date: October 7, 2011Edition Number: 1Section / Paragraph Reference
3、: Sections 75 and 76Subject: Performance tests for High Power Speaker ArraysDECISION:PERFORMANCE TESTS - HPSA75 General75.1 HPSA Systems75.1.1 HPSA systems shall comply with the requirements of this section 76.75.2 Integral control equipment and separate subsystems75.2.1 Electronic equipment either
4、integral with the HPSA or in a separate subsystem shall meet therequirements of 48 - 74.76 HPSA Performance Tests76.1 Directivity Test76.1.1 The HPSA shall be mounted as in normal service and located and oriented as described in 76.1.3.The HPSA shall be driven by pink noise at rated power input. The
5、 sound pressure level of the 1/3 octaveband centered at 1000 Hz shall be measured unweighted in the forward horizontal and vertical planes ofthe reference axis.76.1.2 The directivity characteristic shall be identified by the angles at which the sound pressure leveldecreases by 3 dB and 6 dB from the
6、 HPSAs rated output when measured at a radius of3mintheforward horizontal and vertical planes of the reference axis.76.1.3 The directivity test measurement shall be made with the HPSA mounted in an anechoic orhemi-anechoic chamber. During the measurement process:a) No obstructions shall exist betwee
7、n the HPSA and microphone;b) The mounting platforms of the HPSA and microphone shall be free from acousticalinterference while conducting measurements;c) The noise floor shall be more than 30 decibels lower than the sound pressure level of theHPSA at rated voltage; andUL COPYRIGHTED MATERIAL NOT AUT
8、HORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULd) On a single-speaker system where the largest sound source dimension is less than 10inches (254 mm), the measurement microphone is to be placed 3.28 feet (1 m) from the front ofthe enclosure, and on axis with the physical ce
9、nter of the enclosure. On a single-speakersystem where the largest sound source is 10 inches or greater, the measurement microphone isto be placed 6.56 feet (2 m) from the front of the enclosure, and on axis with the physicalcenter of the enclosure. On multiple-driver speaker systems, the measuremen
10、t microphone is tobe placed 6.56 feet (2 m) on an axis defined by the manufacturer.76.1.4 Measurements are not prohibited from being made in other locations when the measurementequipment employed is capable of simulating a non-reflective environment.76.2 HPSA System Performance76.2.1 HPSA System Per
11、formance76.2.1.1 HPSA Speech Intelligibility76.2.1.1.1 An HPSA shall meet speech intelligibility requirements listed below:76.2.1.1.2 When the STIPA test signal is injected into an HPSA system, the STI (Speech TransmissionIndex) of a high powered speaker array shall be 0.7 or higher.76.2.1.1.3 HPSA
12、products utilizing microphone input(s) shall comply with 76.2.1.1.6.1 and 76.2.1.1.6.2.76.2.1.1.4 HPSA products utilizing direct injection input(s) shall comply with 76.2.1.1.6.3 and 76.2.1.1.6.4.76.2.1.1.5 HPSA products utilizing both microphone input(s) and direct injection unputs shall comply wit
13、h76.2.1.1.6.1 through 76.2.1.1.6.4.76.2.1.1.63 Speech intelligibility measurement shall be made with the HPSA mounted in an anechoic orhemi-anechoic chamber. During the measurement process:a) No obstructions shall exist between the HPSA and microphone;b) The mounting platforms of the HPSA and microp
14、hone shall be free from acousticalinterference while conducting measurements;c) The noise floor shall be more than 30 decibels lower than the sound pressure level of theHPSA at rated voltage; andd) On a single-speaker system where the largest sound source dimension is less than 10inches (254 mm), th
15、e measurement microphone is to be placed 3.28 feet (1 m) from the front ofthe enclosure, and on axis with the physical center of the enclosure. On a single-speakersystem where the largest sound source is 10 inches or greater, the measurement microphone isto be placed 6.56 feet (2 m) from the front o
16、f the enclosure, and on axis with the physicalcenter of the enclosure. On multiple-driver speaker systems, the measurement microphone is tobe placed 6.56 feet (2 m) on an axis defined by the manufacturer.e) Measurements are to be made after the completion of each of the tests identified in Table76.1
17、 below. The sample shall be energized at nominal rated voltage and frequency per Section29.1.2, and mounted in an anechoic or hemi-anechoic chamber.STANDARD NUMBER: UL 2572 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable 76.1Tests req
18、uiring Intelligibility measurementsTest Section referenceHigh Temperature test (storage) 76.4.1.1.1 / 76.5.1.1.1 / 76.6.1.1.1High Temperature test (operational) 76.4.1.1.2 / 76.5.1.1.2 / 76.6.1.1.2Low Temperature test (storage) 76.4.1.2.1 / 76.5.1.2.1 / 76.6.1.2.1Low Temperature test (operational) 7
19、6.4.1.2.2 / 76.5.1.2.2 / 76.6.1.2.2Solar Radiation 76.4.1.3 / 76.5.1.3Humidity test 76.4.1.6 / 76.5.1.6 / 76.6.1.3Endurance 76.2.1.476.2.1.1.6.1 System Calibration via System Microphone Input76.2.1.1.6.1.1 A 1 kHz sine-wave tone ( 100 Hz) at between 60 and 70 dBA-fast response shall beintroduced fou
20、r inches from the system microphone on-axis, perpendicular to the face of the microphone.76.2.1.1.6.1.2 Utilizing the signal described in 76.2.1.4.1.1, the gain of the system shall be adjusted tomatch the rated output to the speaker. 76.2.1.1.6.1.3 The system under test, calibrated as described in76
21、.2.1.1.6.1.1 76.2.1.1.6.1.5 shall have no more than a 3dB difference between manual paging toneusing the system microphone and any pre-recorded tone, where utilized.76.2.1.1.6.1.4 The dBA measurement shall be made using an integrating/averaging meter and averagedover approximately 10 seconds of voic
22、e announcement to compensate for voice amplitude modulation.76.2.1.1.6.1.5 System under test employing more than one emergency paging microphone and/orpre-recorded message units shall have the primary units calibrated first. The secondary units shall thenbe tested to ensure that the signals produced
23、 throughout the system under test are at the same amplitudeas the primary units.76.2.1.1.6.2 Talk Box STI Measurement76.2.1.1.6.2.1 Replace the 1 kHz calibration signal with the STIPA signal and configure the analyzer toSPLA fast response measurement mode.76.2.1.1.6.2.2 The STIPA signal shall be int
24、roduced four inches from the analyzer microphone on-axis,perpendicular to the face of the microphone.76.2.1.1.6.2.3 The talk box volume shall be adjusted to measure the same output level as determined in76.1.1.6.1.1.76.2.1.1.6.2.4 The HPSA microphone shall then replace the STI analyzers microphone w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL2572CRD2014ULSTANDARDFORSAFETYMASSNOTIFICATIONSYSTEMSSECTIONPARAGRAPHREFERENCESECTIONS75AND76SUBJECTPERFORMANCETESTSFORHIGHPOWERSPEAKERARRAYSEDITIONPDF

链接地址:http://www.mydoc123.com/p-1067982.html