UL 250 CRD-2011 UL Standard for Safety Household Refrigerators and Freezers - Section Paragraph Reference New Supplement SB Subject Smart Enabled Refrigerators and Freezers Supers .pdf
《UL 250 CRD-2011 UL Standard for Safety Household Refrigerators and Freezers - Section Paragraph Reference New Supplement SB Subject Smart Enabled Refrigerators and Freezers Supers .pdf》由会员分享,可在线阅读,更多相关《UL 250 CRD-2011 UL Standard for Safety Household Refrigerators and Freezers - Section Paragraph Reference New Supplement SB Subject Smart Enabled Refrigerators and Freezers Supers .pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): SHZZ, SHMRStandard Number: UL 250Edition Date: November 1, 1993Edition Number: 10Section / Paragraph Reference: New Supplement SBSubject: Smart Enabled Refri
3、gerators and FreezersSupersedes prior Certification Requirement Decision dated 2011-03-04DECISION:(For the sake of clarity, the following new text is not underlined)Supplement SBSafety of Smart Enabled Household Refrigerators and FreezersSB1 ScopeSB1.1 These requirements apply to household refrigera
4、tors and freezers intended to receive and respondto communication signals or data relating to power billing rate or demand response.SB1.2 Appliances covered by SB1.1 are commonly identified as “smart” appliances or “smart enabled”and are intended to interact with the “Smart Grid,” as described by th
5、e US Energy Independence andSecurity Act of 2007, or other communications networks not identified as Smart Grid.SB1.3 These requirements do not address the integrity of any output signal or data to the network devicesor interoperability with other devices.SB1.4 These requirements supplement those sp
6、ecified in the Standard for Safety of HouseholdRefrigerators and Freezers, UL 250 and in the Standard for Household and Similar Electrical Appliances,Part 2: Particular Requirements for Refrigerating Appliances, Ice-Cream Appliances and Ice-Makers, UL60335-2-24.SB1.5 These requirements contemplate “
7、smart grid” technology as described by the U.S. EnergyIndependence and Security Act of 2007 that is integral with the appliance or incorporated as an accessory(wired to the appliance or wireless with a corresponding appliance receiver) on the appliance or in thesame occupancy as the appliance.SB1.6
8、These requirements encompass accessory devices to which multiple appliances may communicateand be smart enabled by providing direction for investigation of such devices in addition to therequirements of standards generally applicable to those devices.SB1.7 These requirements do not apply to communic
9、ation network devices that control appliances viasimple power on-off, building wiring devices, panelboard mounted devices or utility meters.SB2 GeneralUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSB2.1 Controls that respond to external comm
10、unication signals or data shall comply with the constructionand performance requirements of UL 60730-1, Automatic Controls for Household and Similar Use, Part 1:General Requirements, and tested as an operating control utilizing the parameters specified in Table SB1.Exception No. 1: This requirement
11、is not applicable to controls located in extra-low voltage circuits wherethe maximum power available does not exceed 15 W. This does not exempt the control from investigationfor compliance with SB3.1.Exception No. 2: Compliance with UL 244A, Solid-State Controls for Appliances, taking into accountcr
12、iteria comparable to that specified in Table SB1, is considered to fulfill this requirement.Exception No. 3: A communication device that is not integral with the appliance control (e.g. on a separatePWB) and complying with UL 60950-1 (Information Technology Equipment Safety - Part 1: GeneralRequirem
13、ents) is considered to fulfill this requirement.Exception No. 4: If the control also incorporates protective functions, these control functions shall beevaluated to the requirements for protective controls. See SB3.2 and SB3.4.SB2.1.1 For the purposes of application of UL 60730-1, EMC emissions test
14、ing of H23 is not applicableto controls which are integral with the appliance, or incorporated as an accessory (wired or wireless) onthe appliance, or in the same occupancy as the appliance.Table SB1Operating Control ParametersInformation Operating Control RequirementOperating Ambient As specified b
15、y the device manufacturer and checked during the Heating Test,Clause 8.6, of the applianceEndurance Testing for power switchingdevicesA) 30,000 cycles for automatic, self-resetting operating controlsB) 6,000 cycles for manual, non-self-resetting operating controlsOvervoltage Category Overvoltage Cat
16、egory IIPollution Degree Controls within the machine compartment or refrigerated compartment are PollutionDegree 3. All others are Pollution Degree 2.SB2.2 With respect to the Endurance Testing indicated in Table SB1, as a result of the testing, the controlshall remain operational and comply with th
17、e Electric Strength Test of UL 60730-1 (Clause 13.2).SB2.3 When the control enclosure forms part of the overall appliance enclosure, the enclosure materialshall comply with Group 1 or Group 2 requirements of Table 4.3, as appropriate. The enclosure for anextra-low voltage circuit only shall be minim
18、um HB.SB2.4 The separation of communication circuits from power and control circuits shall be evaluated for riskof electric shock in accordance with Clause 4.12.Exception: Compliance with the separation of circuits requirements of UL 60730-1 or UL 60950-1 isconsidered to fulfill this requirement.SB2
19、.5 A communication or display device, such as a router or monitor, provided as an accessory for usewith the appliance, shall comply with UL 60950-1.SB2.5.1 The power supply cord of an external communication device shall comply with this standard orUL 60950-1, except Types SP-2, SPE-2, SPT-2, NISP-2,
20、 NISPE-2, NISPT-2 are not allowed.STANDARD NUMBER: UL 250 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULException: This requirement is not applicable to external communication or display devices powered viaconnection to communication or d
21、ata ports on the appliance which are located in extra low voltage circuits.SB2.5.2 If the external communication or display device is grounded via bonding with the applianceenclosure, the bonding requirements of the appliance standard shall be applied.SB2.5.3 Grounding connections for external commu
22、nication or display devices shall be made beforepower connections and shall break only after power connections are broken (“make first, break last”).SB2.5.4 Functional grounding shall not be relied upon for equipment grounding or bonding.NOTE: Functional grounding is grounding of a point in an appli
23、ance or in a system, which is necessary for a purpose other thansafety.SB2.5.5 External communication conductors and cables shall comply with UL 60950-1.SB2.6 Communication conductors and cables within the appliance shall be evaluated as internal wiring inaccordance with this appliance standard.SB2.
24、7 Communication connectors and data ports accessible to the user and service personnel shallcomply with UL 60950-1. Otherwise, communication connectors and data ports shall be evaluated inaccordance with this appliance standard.SB2.7.1 With the exception of communication-on-power-line technology, an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL250CRD2011ULSTANDARDFORSAFETYHOUSEHOLDREFRIGERATORSANDFREEZERSSECTIONPARAGRAPHREFERENCENEWSUPPLEMENTSBSUBJECTSMARTENABLEDREFRIGERATORSANDFREEZERSSUPERSPDF

链接地址:http://www.mydoc123.com/p-1067960.html