UL 250 CRD-2008 UL Standard for Safety Household Refrigerators and Freezers - Section Paragraph Reference Various Subject Supercedes prior Certification Requirement Decision issue.pdf
《UL 250 CRD-2008 UL Standard for Safety Household Refrigerators and Freezers - Section Paragraph Reference Various Subject Supercedes prior Certification Requirement Decision issue.pdf》由会员分享,可在线阅读,更多相关《UL 250 CRD-2008 UL Standard for Safety Household Refrigerators and Freezers - Section Paragraph Reference Various Subject Supercedes prior Certification Requirement Decision issue.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): SHZZStandard Number: UL 250Edition Date: November 1, 1993Edition Number: 10Section / Paragraph Reference: VariousSubject: Supercedes prior Certification Requ
3、irement Decision issued February 1,2007.DECISION:2.26 REFRIGERATED KITCHEN UNIT A unit consisting of a refrigerator in combination with any of thefollowing: a range, a microwave, and/or a sink, or both.a) rangeb) microwavec) sink4.5.15 For switches and other electrical components located in areas wh
4、ere disconnection of the leadswould result in exposure of an uninsulated live part or reduction of electrical spacings, a means forsimultaneous disconnection of the leads shall be provided.4.7.1 Except as indicated in 4.7.7, a door, drawer, or lid permitting entry into a refrigerated storage spaceth
5、at has a minor dimension of 203.2 mm (8 inches) or more and a volume of 0.06 m3(2 cubic feet) ormore, with any arrangement or removal of shelving, shall be constructed so that it will open easily fromthe inside by a force applied outwardly to the door, drawer, or to a release actuator. See door latc
6、h releasetest, Clause 8.28.4.10.1.2 Wiring shall have insulation rated for the potential involved and the temperature to which it maybe subjected. Compliance is to be judged on the basis of the temperatures measured during theapplicable temperature tests specified in Clauses 8.6 and 8.98.UL COPYRIGH
7、TED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULTable 4.9 Typical wiringGroup Type of wire, cord, or cableaWire size Minimum Nominalinsulation thicknessmm2No. AWG mm InchA Appliance wiring material having thermoplasticinsulation, with nominal insulation
8、thicknessesshown at the right.3.3 0.82 5.3and smaller10 and smaller 0.8 0.686 2/64 0.027B Appliance wiring material having thermoplasticor thermoset insulation, with nominal insulationthicknesses shown at right.0.82 and smaller 18 and smaller 1.6 1.37d4/64 0.054d1.3 16 1.6 1.37d4/64 0.054d2.1 14 2.0
9、 1.70e5/64 0.067e3.3 12 2.0 1.70e5/64 0.067eC Appliance wiring material having rubberinsulation, with insulation thicknesses shown atthe right.Same as for Group BdTotal wire insulation thickness can be achieved by use of 0.8 69 mm (2/64 0.027 inch) insulation integral to the wire plus 0.869 mm (1/32
10、 0.027 inch) thick supplemental sleeving, such as fiberglass, etc.eTotal wire insulation thickness can be achieved by use of 1.203 mm (3/64 0.040 inch) insulation integral to the wire plus 0.869 mm (1/32 0.027 inch) thick supplemental sleeving, such as fiberglass, etc.5.8.5 A switching device that m
11、ay be called upon to break controls a motor load under locked rotorconditions of other than the clock motor type shall have a current interrupting capacity horsepower or anequivalent locked rotor ampere rating not less than the locked rotor current that of the motor to becontrolled. This may be a lo
12、cked rotor ampere (LRA) or equivalent horsepower rating.5.8.7 A switching device that controls an incandescent lamp or lamps shall be rated for the control oftungsten-filament lamps.Exception No. 1: A snap switch may be used to control a .Exception No. 2: An ac general-use snap switch may be used to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL250CRD2008ULSTANDARDFORSAFETYHOUSEHOLDREFRIGERATORSANDFREEZERSSECTIONPARAGRAPHREFERENCEVARIOUSSUBJECTSUPERCEDESPRIORCERTIFICATIONREQUIREMENTDECISIONISSUEPDF

链接地址:http://www.mydoc123.com/p-1067957.html