UL 250 CRD-2007 UL Standard for Safety Household Refrigerators and Freezers - Section Paragraph Reference Various (Edition 10 November 01 1993)《家用制冷机和冷冻机的UL安全标准 节 段落参考 多项 (第十版 199.pdf
《UL 250 CRD-2007 UL Standard for Safety Household Refrigerators and Freezers - Section Paragraph Reference Various (Edition 10 November 01 1993)《家用制冷机和冷冻机的UL安全标准 节 段落参考 多项 (第十版 199.pdf》由会员分享,可在线阅读,更多相关《UL 250 CRD-2007 UL Standard for Safety Household Refrigerators and Freezers - Section Paragraph Reference Various (Edition 10 November 01 1993)《家用制冷机和冷冻机的UL安全标准 节 段落参考 多项 (第十版 199.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories (UL). Itis normative for the applicable
2、UL Product Certification Program(s); however, it is currently not part ofthe UL Standard(s) referenced below.Product Category (CCN): SHZZ, SHMRStandard Number: UL 250Edition Date: November 1, 1993Edition Number: 10Section / Paragraph Reference: VariousDECISION:Revise UL 250 to include additional req
3、uirements regarding UV radiation. All the following text is “new.”(New section)4.4A Protection from Overexposure to Ultraviolet Radiation4.4A.1.1 Refrigerators capable of producing ultraviolet (UV) radiation shall be investigated for emission ofultraviolet radiation in accordance with the ultraviole
4、t irradiance test, Sec. 8.31Exception: Exception: Products exclusively identified for the use of lamps rated “Exempt Risk Group” byANSI/IES RP-27.1.4.4A.1.2 UV generators accessed by other than trained service personnel shall have features to minimizethe risk of overexposure of users. User access to
5、 ultraviolet radiation that may result in overexposure shallbe prevented by reliable means, such as enclosures and interlocks.4.4A.1.3 UV generators that emit more than 0.1 microwatt/cm2for an eight-hour period shall be providedwith a means to eliminate emission of ultraviolet radiation outside the
6、enclosure during periods of normaluse while emissions are not desired. When determining compliance with this requirement, user accessiblesurfaces of the refrigerated compartments are considered outside the enclosure.4.4A.1.4 Interlocks used to minimize risk of overexposure to ultraviolet radiation s
7、hall be reliable. Theactuator of an interlock shall be located so that unintentional operation is unlikely and it is not able to bedefeated with the articulate probe shown in Figure 4.1.(New Paragraphs)4.8.1.8 Polymeric enclosures, internal wiring, and other component parts shall be resistant to the
8、 level andduration of UV radiation to which they are exposed, before and after any anticipated mechanical stressesto which they may be subjected, if degradation would result in non-compliance with other requirements ofthis Standard.4.8.1.8.1 Polymeric parts provided to minimize the risk of overexpos
9、ure to UV radiation are considered tocomply with 4.8.1.8 if they comply with the tests referenced in paragraph 8.31.3 and:a) the thickness is greater than 0.5 mm (0.020 in.), orUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULb) where the test
10、UV frequency is representative of the UV generator, the polymeric materialcomplies with the Ultraviolet Light Exposure evaluation in UL 746C, the Standard for PolymericMaterials Use In Electrical Equipment Evaluations.(New section)8.31 Ultraviolet Irradiance test8.31.1 Emissions of ultraviolet radia
11、tion from the refrigerators shall be investigated in accordance with theAmerican Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Values andBiological Indices.8.31.2 Testing shall be performed in the condition(s) most likely to result in the highest emission levels,including
12、removal or adjustment of drawers, guards or operating settings, and with doors opened andclosed. The test shall be performed using a new lamp (or other integral radiation source) representativeof the maximum emission capability (including user replacement parts). The measurement device shall beplace
13、d as close as possible to the radiation source to represent the users body.8.31.3 Parts provided to minimize the risk of overexposure to ultraviolet radiation shall be resistant todegradation from mechanical abuse. After subjecting the parts to the tests of Sections 8.30 and 9.6, theparts shall be v
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL250CRD2007ULSTANDARDFORSAFETYHOUSEHOLDREFRIGERATORSANDFREEZERSSECTIONPARAGRAPHREFERENCEVARIOUSEDITION10NOVEMBER011993

链接地址:http://www.mydoc123.com/p-1067956.html