UL 2225-2013 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations (Fourth Edition Reprint with revisions through and including March 24 2017.pdf
《UL 2225-2013 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations (Fourth Edition Reprint with revisions through and including March 24 2017.pdf》由会员分享,可在线阅读,更多相关《UL 2225-2013 UL Standard for Safety Cables and Cable-Fittings For Use In Hazardous (Classified) Locations (Fourth Edition Reprint with revisions through and including March 24 2017.pdf(45页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 2225 Cables and Cable-Fittings For Use In Hazardous (Classied) Locations STANDARD FOR SAFETYUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION
2、 FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Cables and Cable-Fittings For Use In Hazardous (Classied) Locations, UL 2225 Fourth Edition, Dated September 30, 2013 Summary of Topics This revision to ANSI/
3、UL 2225 is being issued to include the following changes in requirements: Revisions for 37.3 and 37.4 to limit the risk of confusion over NEC permitted cable ttings being marked as though they are listed for the location by specically prohibiting such marking. The new and revised requirements are su
4、bstantially in accordance with Proposal(s) on this subject dated October 2, 2015 and December 18, 2015. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. All rights reserved. No part of this publication may be repro
5、duced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the impl
6、ied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard
7、, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to
8、defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. JANUARY 29, 20
9、16 UL 2225 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 29, 2016 UL 2225 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 30, 2013 (Tit
10、le Page Reprinted: January 29, 2016) 1 UL 2225 Standard for Cables and Cable-Fittings For Use In Hazardous (Classied) Locations First Edition July, 1996 Second Edition December, 2005 Third Edition February, 2011 Fourth Edition September 30, 2013 This ANSI/UL Standard for Safety consists of the Fourt
11、h edition including revisions through January 29, 2016. The most recent designation of ANSI/UL 2225 as an American National Standard (ANSI) occurred on January 29, 2016. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Commen
12、ts or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electro
13、nic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2016 UNDERWRITERS LABORATORIES INC. ANSI/UL 2225-2016UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR
14、 FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SEPTEMBER 30, 2013 UL 2225 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 Units of Measurement .6 3 Undated References
15、 6 4 Glossary .6 PART I CABLES CONSTRUCTION 5 General 7 PERFORMANCE 6 General 8 7 Impact Test Low Temperature 8 8 Mechanical Damage Impact 8 9 Crushing Test 9 10 Flame Test .9 MARKING 11 General .9 PART II EXPLOSIONPROOF AND DUST-IGNITIONPROOF CABLE SEALING FITTINGS CONSTRUCTION 12 General .9 13 Mat
16、erial 10 14 Bonding Continuity 10 15 Joints 10 16 Supply Connections for Flameproof d and Explosionproof Fittings .11 17 Seal .11 18 Protection Against Corrosion 12 19 Materials Applied to Joint Surfaces 12 PERFORMANCE 20 General .13 21 Torque .13 22 Resistance to Impact Test .13 23 Explosion Tests
17、.17 24 Hydrostatic Pressure Tests .19 25 Dust Penetration Test 20 26 Leakage of Sealing Fittings Test 21 27 High Humidity Tests .21 SEPTEMBER 30, 2013 UL 2225 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 28 Non-Metallic Materials Tests 2
18、1 28.1 General .21 28.2 Chemical compatibility by material samples .22 28.3 Chemical compatibility by complete end product tests .24 28.4 Test for accumulation of static electricity .26 29 Tests on Epoxy Sealing Compounds 27 30 Enclosure Types and Degree of Protection .28 PART III AEx CABLE FITTINGS
19、 AND EXTRA-HARD USAGE CORD CONNECTORS CONSTRUCTION 31 General 28 32 All AEx Cable Fittings and Cord Connectors 29 33 Flameproof d Construction 29 34 Increased Safety e Construction .29 35 Dust Ignition Protection by Enclosure t or tD 30 PERFORMANCE 36 All AEx Cable Fittings and Cord Connectors .31 3
20、6.1 General .31 36.2 Unarmored cable tting strain relief performance 31 36.3 Strain relief test .31 36.4 Mechanical strength .32 36.5 Armored cable tting strain relief performance 32 36.6 Flameproof tting or connector performance .32 36.7 Increased safety tting or connector performance .33 36.8 Dust
21、 exclusion by enclosures t or tD .34 MARKINGS 37 Details .35 SEPTEMBER 30, 2013 UL 2225 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover Type MC-HL metal-clad cable for use in hazardous (clas
22、sied) locations, Class I, Division 1, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class I, Zone 1, Groups IIA, IIB, and IIC; and Zone 20, 21, and 22 in accordance with the National Electrical Code, NFPA 70. 1.2 These requirements cover Type ITC-HL instrumentation tray cable for
23、use in hazardous (classied) locations, Class I, Division 1, Groups A, B, C, and D, and Class I, Zone 1, Groups IIA, IIB, and IIC; and Zone 20, 21, and 22 in accordance with the National Electrical Code, NFPA 70. 1.3 These requirements cover Type TC-ER-HL tray cable for use in hazardous (classied) lo
24、cations, Class I, Zone 1, Groups IIA, IIB, and IIC in accordance with the National Electrical Code, NFPA 70. 1.4 These requirements cover explosionproof and dust-ignitionproof cable sealing ttings for use in hazardous (classied) locations, Class I, Division 1 and 2, Groups A, B, C, and D; Class II,
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL22252013ULSTANDARDFORSAFETYCABLESANDCABLEFITTINGSFORUSEINHAZARDOUSCLASSIFIEDLOCATIONSFOURTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGMARCH242017PDF

链接地址:http://www.mydoc123.com/p-1067859.html