UL 217 CRD-2016 UL Standard for Safety Single and Multiple Station Smoke Alarms - Section Paragraph Reference 37 6 1 1 (NEW) 37 6 2 37 6 3 Subject To permit the use of a supervise.pdf
《UL 217 CRD-2016 UL Standard for Safety Single and Multiple Station Smoke Alarms - Section Paragraph Reference 37 6 1 1 (NEW) 37 6 2 37 6 3 Subject To permit the use of a supervise.pdf》由会员分享,可在线阅读,更多相关《UL 217 CRD-2016 UL Standard for Safety Single and Multiple Station Smoke Alarms - Section Paragraph Reference 37 6 1 1 (NEW) 37 6 2 37 6 3 Subject To permit the use of a supervise.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): UTGT,UTGT2, UTHAStandard Number: UL 217Standard Title: Standard for Smoke AlarmsEdition Date: October 30, 2015Edition Number: 8Section / Paragraph Reference:
3、 37.6.1.1 (NEW), 37.6.2, 37.6.3Subject: To permit the use of a supervised battery (or batteries) as the primary (andsole) power source for smoke alarm accessories.DECISION:37.6 Accessories37.6.1 Unless specifically indicated otherwise, the applicable performance requirements of this standardshall al
4、so apply to any remote accessories with which it is to be employed - for example, but not limitedto:a) Normal Operation Test, Section 38;b) Circuit Measurement Test, Section 56;c) Overvoltage and Undervoltage Tests, Section 57;d) Temperature Test, Section 58;e) Jarring Test, Section 61;f) Overload T
5、ests, Section 69;g) Endurance Test, Section 70;h) Variable ambient temperature and humidity test, 88.3;i) Leakage Current Test, Section 73;j) Transient Tests, Section 66;k) Dielectric Voltage-Withstand Test, Section 77;l) Tests on Polymeric Materials, Section 79;m) Drop Test, Section 83 (portable ap
6、pliance only);n) Audibility Test, Section 84.n) Audibility Test, Section 84.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM UL37.6.1.1 The primary power supply of optional accessories shall be either a utility supply (commercial lightand power s
7、ource) or a supervised integral battery or batteries.37.6.2 Optional accessories used to assist persons with disabilities by enhancing the low frequency orsignaling a tactile appliance shall include a source of secondary power equal to that of the smoke and heatalarms that the unit is compatible wit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL217CRD2016ULSTANDARDFORSAFETYSINGLEANDMULTIPLESTATIONSMOKEALARMSSECTIONPARAGRAPHREFERENCE37611NEW37623763SUBJECTTOPERMITTHEUSEOFASUPERVISEPDF

链接地址:http://www.mydoc123.com/p-1067836.html