UL 2115-2017 UL Standard for Safety Processed Solid-Fuel Firelogs and Firestarters (Fourth Edition)《处理的固体燃料燃材和起火剂》.pdf
《UL 2115-2017 UL Standard for Safety Processed Solid-Fuel Firelogs and Firestarters (Fourth Edition)《处理的固体燃料燃材和起火剂》.pdf》由会员分享,可在线阅读,更多相关《UL 2115-2017 UL Standard for Safety Processed Solid-Fuel Firelogs and Firestarters (Fourth Edition)《处理的固体燃料燃材和起火剂》.pdf(21页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL ANSI/CAN/UL/ULC 2115:2017, Processed Solid-Fuel Firelogs and Firestarters STANDARD FOR SAFETY JOINT CANADA-UNITED STATES NATIONAL STANDARD ANSI/UL 2115-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZE
2、D FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL SCC FOREWARD National Standard of Canada A National Standard of Canada is a standard developed by a Standards Council of Canada (SCC) accredited Standards Development Organization, in compliance with requirements and guidance set
3、out by SCC. More information on National Standards of Canada can be found at www.scc.ca. SCC is a Crown corporation within the portfolio of Innovation, Science and Economic Development (ISED) Canada. With the goal of enhancing Canadas economic competitiveness and social well-being, SCC leads and fac
4、ilitates the development and use of national and international standards. SCC also coordinates Canadian participation in standards development, and identies strategies to advance Canadian standardization efforts. Accreditation services are provided by SCC to various customers, including product cert
5、iers, testing laboratories, and standards development organizations. A list of SCC programs and accredited bodies is publicly available at www.scc.ca.UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Processed Solid-
6、Fuel Firelogs and Firestarters ANSI/CAN/UL/ULC 2115 Fourth Edition, Dated November 7, 2017 Summary of Topics This is the Fourth Edition of the Standard for Processed Solid-Fuel Firelogs and Firestarters, ANSI/CAN/UL/ULC 2115. The new requirements are substantially in accordance with Proposal(s) on t
7、his subject dated February 3, 2017 and August 4, 2017. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides t
8、his Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of pro
9、ts, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this S
10、tandard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or devi
11、ation introduced while purchaser is storing an electronic Standard on the purchasers computer system. NOVEMBER 7, 2017 ANSI/CAN/UL/ULC 2115 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMBER 7, 2017 ANSI/CAN/UL/ULC 2115 tr2 No Text
12、on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL November 7, 2017 1 UL/ULC 2115 Standard for Processed Solid-Fuel Firelogs and Firestarters First Edition February, 1999 Second Edition November, 2007 Third Edition October, 2015 Fou
13、rth Edition November 7, 2017 This ANSI/CAN/UL/ULC Standard for Safety consists of the Fourth edition. The most recent designation of ANSI/UL 2115 as an American National Standard (ANS) occurred on November 7, 2017. ANSI approval for a standard does not include the Cover Page, Transmittal Pages and T
14、itle Page. This standard has been approved as a National Standard of Canada (NSC) by the Standards Council of Canada (SCC). COPYRIGHT 2017 UNDERWRITERS LABORATORIES INC. ANSI/UL 2115-2017UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL NOVEMB
15、ER 7, 2017 PROCESSED SOLID-FUEL FIRELOGS AND FIRESTARTERS - UL/ULC 2115 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS Preface . 4 INTRODUCTION 1 Scope .7 2 Units of Measurement .7 3 Reference Publications 7 4
16、 Glossary .7 5 Compliance 7 PERFORMANCE - FIRELOGS AND FIRESTARTERS 6 Aging Test .8 7 Spontaneous Heating Test .8 8 Heat Release Rate Calorimeter Test 9 MARKINGS - FIRELOGS 9 Firelog Marking and Instructions .10 PERFORMANCE - FIRESTARTERS 10 Ignition and Burn Test .12 11 Liquid Residue Test .12 12 V
17、apour Hazard .12 13 Flash Fire 13 14 Properties Analysis .13 MARKING - FIRESTARTERS 15 Firestarter Markings and Instructions 13 ANNEX A(Informative) A1.1 Reference Standards .A1 NOVEMBER 7, 2017 PROCESSED SOLID-FUEL FIRELOGS AND FIRESTARTERS - UL/ULC 2115 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR
18、FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL Preface This is the Fourth Edition of the Standard for Processed Solid-Fuel Firelogs and Firestarters. This Edition of the Standard has been formally approved by the ULC Standards Committee on Factory-Built Fireplace, Chimneys and Vents
19、 and the UL Standards Technical Panel on Solid-Fuel Burning Appliances. This Standard has been developed in compliance with the requirements of SCC and ANSI for accreditation of a Standards Development Organization. Only metric SI units of measurement are used in this Standard. If a value for measur
20、ement is followed by a value in other units in parentheses, the second value may be approximate. The rst stated value is the requirement. Appendix A, identied as Informative, is for information purposes only. UL is accredited by the American National Standards Institute (ANSI) and the Standards Coun
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL21152017ULSTANDARDFORSAFETYPROCESSEDSOLIDFUELFIRELOGSANDFIRESTARTERSFOURTHEDITION 处理 固体燃料 起火 PDF

链接地址:http://www.mydoc123.com/p-1067809.html