《UL 1795-2009 UL Standard for Safety Hydromassage Bathtubs (Fourth Edition Reprint with Revisions Through and Including January 7 2015)《水按摩浴缸》.pdf》由会员分享,可在线阅读,更多相关《UL 1795-2009 UL Standard for Safety Hydromassage Bathtubs (Fourth Edition Reprint with Revisions Through and Including January 7 2015)《水按摩浴缸》.pdf(114页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1795 Hydromassage BathtubsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODU
2、CTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Hydromassage Bathtubs, UL 1795 Fourth Edition, Dated August 5, 2009 Summary of Topics This revision to UL 1795 is being issued to remove the reference to the withdrawal date of UL 873 and to address universal upkeep of UL St
3、andards for Safety. These revisions are considered to be non-substantive and not subject to ULs STP process. Text that has been changed in any manner or impacted by ULs electronic publishing system is marked with a vertical line in the margin. Changes in requirements are marked with a vertical line
4、in the margin and are followed by an effective date note indicating the date of publication or the date on which the changed requirement becomes effective. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, elect
5、ronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be
6、liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility
7、 of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liabili
8、ty, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, table
9、s, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMEN
10、TS notice. JANUARY 7, 2015 UL 1795 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL JANUARY 7, 2015 UL 1795 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL
11、AUGUST 5, 2009 (Title Page Reprinted: January 7, 2015) 1 UL 1795 Standard for Hydromassage Bathtubs First Edition February, 1988 Second Edition November, 1993 Third Edition March, 1999 Fourth Edition August 5, 2009 This UL Standard for Safety consists of the Fourth Edition including revisions throug
12、h January 7, 2015. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neit
13、her a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT 2015 UNDERWRITERS LABORATORIES INC.UL COPYRIGHTED MATERIAL NOT AUTHORI
14、ZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL AUGUST 23, 2011 HYDROMASSAGE BATHTUBS - UL 1795 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .7 2 Components 7 3 U
15、nits of measurement .7 4 Undated references .8 5 Glossary .8 6 Accessories .8D CONSTRUCTION 7 General 8D 7A Component Specications .8D 7A.1 General 8D 7A.2 Quick-connect wire connectors 8E 7A.3 Terminal blocks 8E 7A.4 Wire connectors .8F 8 Frame and Enclosure 8F 8.1 General 8F 8.2 Barriers 11 8.3 Mo
16、ving parts 14 9 Mechanical Assembly 14 9.1 General 14 9.2 Adhesive used to secure parts 15 10 Accessibility of Uninsulated Live Parts, Film-Coated Wire, and Moving Parts .16 11 Provisions for Servicing 21 12 Resistance to Corrosion .22 13 Power Supply Connections 23 13.1 General .23 13.2 Permanently
17、 connected units 24 13.3 Cord- and plug-connected units 27 14 Live Parts 27 15 Internal Wiring 28 15.1 General .28 15.2 Splices and connections 29 16 Separation of Circuits .30 17 Grounding .31 18 Equipotential Bonding .32 19 Circuits 33 19.1 General .33 19.2 Secondary circuits 34 19.3 Circuits acce
18、ssible to a bathtub occupant .34 19.4 Safety circuits 34 20 Insulation 34 20.1 Electrical insulation .34 20.2 Thermal insulation 35 21 Printed-Wiring Boards .35 22 Spacings 36 22.1 General .36 22.2 Class 2 circuits .36 AUGUST 23, 2011 HYDROMASSAGE BATHTUBS - UL 1795 3UL COPYRIGHTED MATERIAL NOT AUTH
19、ORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 22.3 Field-wiring terminals .36 22.4 Other than eld-wiring terminals 36 22.5 Safety circuits 36 22.6 Printed-wiring boards .36 22.7 Spacings within motors 36A 23 Ground-Fault Circuit-Interrupters 36A 24 Electric Heaters .36A
20、25 Hydromassage Bathtubs Congured for Field-Installed Heaters .36A 26 Field-Installed Heaters .36B 27 Heater Protection 36B 28 Motors .37 28A Motor Overload Protection 38 29 Air Blowers 39 30 Overload Protection .39 31 Leakage Current Collectors 42 32 Gaskets 42A 33 Luminaires 42A 34 Capacitors 42A
21、35 Transformers .42B 36 Switches, Receptacles, and Controls 44 36.1 General .44 36.2 Manually-operated switches 44A 36.3 Reduction of risk of injury to persons 44B 37 Sharp Edges 44B 38 Temperature-Regulating Controls 44B 38.1 General 44B 38.2 Temperature-regulating controls with a marked or implied
22、 “off” position .45 39 Temperature-Limiting Controls 46 39.1 General .46 39.2 Temperature-sensitive controls .46 39.3 Pressure-sensitive controls 48 39A Temperature sensing, thermistor devices .48B 40 Parts Subject to Pressure 49 41 Protection Against Entrapment .49 42 Direct Plug-In Controls 50 42A
23、 Ozone Generators .50A PERFORMANCE 43 General 51 44 Insulation Resistance Test .51 45 Starting Current Test 51 46 Power Input Test .52 47 Temperature Test .52 48 Dielectric Voltage-Withstand Test .56 48.1 General .56 48.2 Class 2 circuits .57 48.3 Printed-wiring boards .57 49 Switch Overload Test .5
24、7 50 Water Temperature Tests 58 50.1 General .58 50.2 Normal operation .58 50.3 Abnormal operation .59 JANUARY 13, 2012 HYDROMASSAGE BATHTUBS - UL 1795 4UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL 51 Water Exposure Test 60 51.1 General .
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL17952009ULSTANDARDFORSAFETYHYDROMASSAGEBATHTUBSFOURTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGJANUARY72015

链接地址:http://www.mydoc123.com/p-1067682.html