UL 14B-2008 UL Standard for Safety Sliding Hardware for Standard Horizontally Mounted Tin-Clad Fire Doors (Ninth Edition Reprint with Revisions Through and Including JULY 17 2017)《.pdf
《UL 14B-2008 UL Standard for Safety Sliding Hardware for Standard Horizontally Mounted Tin-Clad Fire Doors (Ninth Edition Reprint with Revisions Through and Including JULY 17 2017)《.pdf》由会员分享,可在线阅读,更多相关《UL 14B-2008 UL Standard for Safety Sliding Hardware for Standard Horizontally Mounted Tin-Clad Fire Doors (Ninth Edition Reprint with Revisions Through and Including JULY 17 2017)《.pdf(38页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 14B Sliding Hardware for Standard, Horizontally Mounted Tin-Clad Fire DoorsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRI
2、GHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Sliding Hardware for Standard, Horizontally Mounted Tin-Clad Fire Doors, UL 14B Ninth Edition, Dated December 15, 2008 SUMMARY OF TOPICS Revision pages have been issued for th
3、e Standard for Sliding Hardware for Standard, Horizontally Mounted Tin-Clad Fire Doors, UL 14B, to reect the reaffirmation of the ANSI approval. No changes in requirements have been made. The revisions are substantially in accordance with Proposal(s) on this subject dated March 8, 2013. All rights r
4、eserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides this Standard as is without warranty of any kind, either expressed o
5、r implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots, lost savings, loss of data, or any other damages arising out of
6、 the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Standard, regardless of the form of the claim. Users of the electron
7、ic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviation introduced while purchaser is storing an electronic Standard
8、on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note following the affected item. The prior text for requirements that
9、 have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. MAY 3, 2013 UL 14B tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL MAY 3, 2013 UL 14B tr2 No Te
10、xt on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 15, 2008 (Title Page Reprinted: May 3, 2013) 1 UL 14B Standard for Sliding Hardware for Standard, Horizontally Mounted Tin- Clad Fire Doors First Edition March, 1917 Sec
11、ond Edition February, 1943 Third Edition November, 1953 Fourth Edition December, 1968 Fifth Edition June, 1973 Sixth Edition January, 1979 Seventh Edition December, 1993 Eighth Edition December, 1998 Ninth Edition December 15, 2008 This ANSI/UL Standard for Safety consists of the Ninth Edition, incl
12、uding revisions through May 3, 2013. The most recent designation of ANSI/UL 14B as an American National Standard (ANSI) occurred on May 3, 2013. ANSI approval for a standard does not include the Cover Page, Transmittal Pages, Title Page, or effective date information. The Department of Defense (DoD)
13、 has adopted UL 14B on October 24, 1984. The publication of revised pages or a new edition of this Standard will not invalidate the DoD adoption. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request i
14、n ULs On-Line Collaborative Standards Development System (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall
15、 remain the sole and exclusive property of UL. COPYRIGHT 2013 UNDERWRITERS LABORATORIES INC. ANSI/UL 14B-2008 (R2013)UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL DECEMBER 15, 2008 UL 14B 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT A
16、UTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .4 2 Units of Measurement .4 3 Undated References 5 CONSTRUCTION 4 General 5 5 Flat Tracks .6 5.1 General .6 5.2 Holes for wall bolts .8 6 Hangers 12 6.1 Hangers for three-ply doors .12 6.2 Tr
17、ack wall brackets 12 6.3 Hangers for two-ply doors 13 7 Front Binders 13 8 Rear Binders and Rear-Binder Pockets .14 9 Stay Rolls .17 10 Chang Strips 23 11 Wedges .25 12 Handles .25 13 Bumpers and Bumper Shoes .26 14 Washers .28 15 Tolerances .28 16 Installation Instructions 28 17 Painting .28 MARKIN
18、G 18 General 29 APPENDIXAS I(Metric) Equivalent for USA Units Shown in Figures and Wood Screw Sizes APPENDIX B Tolerances DECEMBER 15, 2008 UL 14B 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements a
19、pply to hardware for horizontally sliding re doors which have demonstrated in re tests re-resistive properties warranting their use with two-ply and three-ply tin-clad re doors tested in accordance with the Standard for Fire Tests of Door Assemblies, UL 10B (NFPA No. 252). 1.2 Requirements for the l
20、ocation and time rating are contained in codes, such as the International Building Code (IBC). The method of installation required for re doors is not included in these codes. Requirements for the details for the installation of horizontally sliding two-ply and three-ply tin-clad re doors are includ
21、ed in the Standard for Fire Doors and Other Opening Protectives, NFPA 80. 1.3 The hardware included in these requirements is designed for mounting standard two-ply and three-ply tin-clad horizontally sliding re doors for protection of openings not exceeding the dimensions for the hourly classication
22、s indicated in Table 1.1. 1.4 These requirements do not cover automatic releasing or closing mechanisms. Table 1.1 Limitations in types and dimensions Type of door Maximum area, Maximum width, Maximum height, Hourly rating ft 2 (m) 2 ft (m) ft (m) Three-ply 120 11.2 12 3.6 12 3.6 3, 1-1/2, 1, 3/4 Tw
23、o-ply 80 7.4 10 3.1 10 3.1 1-1/2, 1, 3/4 2 Units of Measurement 2.1 When a value for measurement is followed by a value in other units in parentheses, the rst stated value is the requirement. SI units as employed are in accordance with the Standard for the Practice for Use of the International Syste
24、m of Units (SI) (the Modernized Metric System), ANSI/ASTM E380-91a. 2.2 The tolerance for all dimensions shall be as specied with the dimension. Where no tolerance is shown, the tolerances specied in Appendix B shall apply. See Appendix B for specications. DECEMBER 15, 2008 UL 14B 4UL COPYRIGHTED MA
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL14B2008ULSTANDARDFORSAFETYSLIDINGHARDWAREFORSTANDARDHORIZONTALLYMOUNTEDTINCLADFIREDOORSNINTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGJULY172017PDF

链接地址:http://www.mydoc123.com/p-1067521.html