《UL 1286 CRD-2013 UL Standard for Safety Office Furnishings - Section Paragraph Reference New Supplement SB Subject Office Furnishings for attachment to the building structure (Edi.pdf》由会员分享,可在线阅读,更多相关《UL 1286 CRD-2013 UL Standard for Safety Office Furnishings - Section Paragraph Reference New Supplement SB Subject Office Furnishings for attachment to the building structure (Edi.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): QAWZ, QAXEStandard Number: UL 1286Standard Title: Standard for Office FurnishingsEdition Date: August 28, 2008Edition Number: 5Section / Paragraph Reference:
3、 New Supplement SBSubject: Office Furnishings for attachment to the building structure.DECISION:INTRODUCTION1 Scope(New Clause)1.5 These requirements also cover Office Furnishings secured to or supported by the building structure.SB OFFICE FURNISHINGS FOR MOUNTING TO BUILDING STRUCTURESINTRODUCTIONS
4、B1 ScopeSB1.1 The requirements of this supplement cover office furnishings attached to the building for stability orsupport.SB1.2 These requirements cover the office furnishing mounting to the building structure and do notevaluate the ability of the building structure to support the load.SB1.3 The o
5、ffice furnishing system attached to the building shall comply with requirements in UL 1286except as modified or supplemented by the requirements of supplement SB.SB2 GlossarySB2.1 MOUNTING SURFACE The building structure where the office furnishing system is secured to.SB2.2 MOUNTING SYSTEM A part of
6、 the office furnishing system that allows the office furnishingsystem to be mounted to the building structure.CONSTRUCTIONSB3 GeneralSB3.1.1 A mounting system shall be constructed so that:UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULa) The
7、user assembly and normal use do not result in a risk of fire, electric shock, or injury topersons; andb) The materials and components are used within their mechanical, electrical, and temperaturelimits.SB3.1.2 An office furniture building mounting system shall be assembled and mounted to the buildin
8、gsurface in accordance with the manufacturers installation instructions.SB3.1.3 The hardware and fasteners used to secure the office furnishing system to the building shall besupplied by the office furnishing manufacturer or shall be specified in sufficient detail in the installationinstructions to
9、insure the installer can properly secure the office furnishing to the building structure.SB3.2 Flammability of MaterialsSB3.2.1 The furnishing and mounting system shall comply with section 19.9.SB3.2.2 A combustible office furnishing building mounting system that covers more than 10 ft2(0.93 m2)of a
10、 wall or ceiling building surface, in any combination of assembly recommended by the installationinstructions, shall be tested in accordance with the Standard for Test for Surface Burning Characteristicsof Building Materials, UL 723. A combustible joining system used to connect individual combustibl
11、e panelsshall be tested in combination with the combustible panel.a) The flame-spread index shall be marked on each combustible panel as specified in SB7.1,andb) The smoke developed index shall be marked on each combustible panel as specified inSB7.1.SB3.2.3 The test results from the Standard for Te
12、st for Surface Burning Characteristics of BuildingMaterials, UL 723 shall be less than or equal to 200 Flame Spread and less than or equal to 450 SmokeDeveloped.SB4.0 MECHANICAL PERFORMANCE TESTSSB4.1.1 Mold Stress TestSB4.1.2 A office furnishing mounting system incorporating a thermoplastic materia
13、l used to support orcarry a structural load whose failure would result in a risk of fire, electric shock, or injury to persons shallwithstand the temperature-stability conditions described in SB4.1.3. Thermoplastic material shall not haveany shrinkage, warpage, or other distortion of the polymeric m
14、aterials, resulting in a risk of fire, electricshock, or injury to persons.SB4.1.3 An unloaded representative office furnishing mounting system is to be placed in a full-draftcirculating-air oven. The air temperature within the oven is to be maintained at 70C (158F) or 10Chigher than the temperature
15、 obtained during the temperature test for 7 hours. The mounting system isallowed to cool to room temperature before conducting the Mounting Securement Test, Section SB4.3.SB4.2 Adhesive TestSB4.2.1 An office furnishing mounting system utilizing adhesives whose failure would result in a risk offire,
16、electric shock, or injury to persons shall be subjected to the conditioning test described in SB4.2.2.STANDARD NUMBER: UL 1286 -2-UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULSB4.2.2 Two representative adhesively secured mounting systems sh
17、all be conditioned as follows:a) One system shall be placed in an air-circulating oven for: 7 days at 100 1.0C (212 1.8F),or 16 days at 90 1.0C (194 1.8F ) or 21 days at 87 1.0C (188 1.8F) or 60 days at 821.0C (179 1.8F); andb) One system shall be conditioned for 7 days in an environment of 85 5 per
18、cent relativehumidity at 32.0 2.0C (89.6 3.6F).Following the adhesive conditioning test the office furnishing mounting system shall be subjected to theMounting Securement Test, Section SB4.3.SB4.3 Mounting Securement TestSB4.3.1 An office furnishing mounting system shall be constructed so there is n
19、o cracking, bending,distortion, or similar damage, to the mounting system, securement means, supporting structure, or anycombination thereof, to the point where any part of the office furnishing mounting system collapses, pullsloose from the building mounting surface or results in the loss of servic
20、eability when loaded in accordancewith sections 32-34.SB4.3.2 The office furnishing mounting system shall be configured in accordance with the following:a) Shelves, platforms, brackets, tables and compartments intended to be attached orsuspended from the mounting system, shall be assembled and secur
21、ed to the mounting system;b) The fasteners and anchors provided or recommended by the manufacturer to be used tosecure the system to the building structure shall be used;c) Tests shall be performed on each of the building surfaces and types to which themanufacturer recommends the mount to be secured
22、 in the installation instructions;d) The mounting and furniture system shall be loaded as specified in sections 32-34; ande) The mounting and furniture system that is adaptable to more than one size or more than oneconfiguration and determined to present different risks than represented by any oneco
23、nfiguration shall be investigated for use with all combinations necessary to determinecompliance with these requirements.SB5.0 Building Mounting SurfacesSB5.1.1 The following building surface constructions are provided for reference. The manufacturer mayspecify other building constructions the syste
24、m is designed for use with. The installation instructions shallbe used to determine the minimum structural building construction limitations that the office furnishingmounting system is intended for use with. Manufactured structural members (trusses, laminated lumber,manufactured I beams of wood or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL1286CRD2013ULSTANDARDFORSAFETYOFFICEFURNISHINGSSECTIONPARAGRAPHREFERENCENEWSUPPLEMENTSBSUBJECTOFFICEFURNISHINGSFORATTACHMENTTOTHEBUILDINGSTRUCTUREEDIPDF

链接地址:http://www.mydoc123.com/p-1067415.html