UL 1086 CRD-2012 UL Standard for Safety Household Trash Compactors - Section Paragraph Reference 40 & 48 Subject Direct Current (DC) Dielectric Test Potentials (Edition 5 June 28 2.pdf
《UL 1086 CRD-2012 UL Standard for Safety Household Trash Compactors - Section Paragraph Reference 40 & 48 Subject Direct Current (DC) Dielectric Test Potentials (Edition 5 June 28 2.pdf》由会员分享,可在线阅读,更多相关《UL 1086 CRD-2012 UL Standard for Safety Household Trash Compactors - Section Paragraph Reference 40 & 48 Subject Direct Current (DC) Dielectric Test Potentials (Edition 5 June 28 2.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): XUUMStandard Number: UL 1086Edition Date: June 28, 2005Edition Number: 5Section / Paragraph Reference: 40 & 48Subject: Direct Current (DC) Dielectric Test Po
3、tentialsDECISION:40.1 (REVISED) An appliance shall withstand for 1 minute without breakdown the application of a DCpotential or an AC 60-Hz essentially sinusoidal potential between live parts and dead metal parts, andbetween live parts of opposite polarity for a test on a capacitor used for radio-in
4、terference elimination orarc-suppression, with the appliance at the maximum operating temperature reached in normal use. Thetest potential shall be:a) One thousand volts1000 V AC or 1400 V DC for an appliance employing a motor rated 1/2hp or less. See 17.4.b) One thousand volts1000 V AC plus twice r
5、ated voltage or 1400 V DC plus 2.8 times ratedvoltage for an appliance employing a motor rated more than 1/2 hp. See 17.4.48.1 (REVISED) Each appliance shall withstand without electrical breakdown, as a routine production-linetest, the application of a DC potential or an AC potential at a frequency
6、within the range of 40 - 70 Hz,between the primary wiring, including connected components, and accessible dead metal parts that arelikely to become energized, and between primary wiring and accessible low-voltage - 42.4 V peak or less- metal parts, including terminals.Table 48.1Production-line test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL1086CRD2012ULSTANDARDFORSAFETYHOUSEHOLDTRASHCOMPACTORSSECTIONPARAGRAPHREFERENCE4048SUBJECTDIRECTCURRENTDCDIELECTRICTESTPOTENTIALSEDITION5JUNE282PDF

链接地址:http://www.mydoc123.com/p-1067317.html