UL 1022-2012 UL Standard for Safety Line Isolation Monitors (Fifth Edition Reprint with revisions through and including August 3 2016)《线路绝缘监视器》.pdf
《UL 1022-2012 UL Standard for Safety Line Isolation Monitors (Fifth Edition Reprint with revisions through and including August 3 2016)《线路绝缘监视器》.pdf》由会员分享,可在线阅读,更多相关《UL 1022-2012 UL Standard for Safety Line Isolation Monitors (Fifth Edition Reprint with revisions through and including August 3 2016)《线路绝缘监视器》.pdf(53页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL 1022 Line Isolation MonitorsUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM ULUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRO
2、DUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL UL Standard for Safety for Line Isolation Monitors, UL 1022 Fifth Edition, Dated April 16, 2012 SUMMARY OF TOPICS The fth edition of the Standard for Safety for Line Isolation Monitors, UL 1022, has been issued to incorporate the following proposals
3、 dated October 28, 2011 and February 17, 2012: ANSI approval of the Standard for Safety for Line Isolation Monitors, UL 1022. Revision to the scope expanding the use of isolated power systems and isolation monitors. The revised requirements are substantially in accordance with Proposal(s) on this su
4、bject dated October 28, 2011, and February 17, 2012. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form by any means, electronic, mechanical photocopying, recording, or otherwise without prior permission of UL. UL provides thi
5、s Standard as is without warranty of any kind, either expressed or implied, including but not limited to, the implied warranties of merchantability or tness for any purpose. In no event will UL be liable for any special, incidental, consequential, indirect or similar damages, including loss of prots
6、, lost savings, loss of data, or any other damages arising out of the use of or the inability to use this Standard, even if UL or an authorized UL representative has been advised of the possibility of such damage. In no event shall ULs liability for any damage ever exceed the price paid for this Sta
7、ndard, regardless of the form of the claim. Users of the electronic versions of ULs Standards for Safety agree to defend, indemnify, and hold UL harmless from and against any loss, expense, liability, damage, claim, or judgment (including reasonable attorneys fees) resulting from any error or deviat
8、ion introduced while purchaser is storing an electronic Standard on the purchasers computer system. The requirements in this Standard are now in effect, except for those paragraphs, sections, tables, gures, and/or other elements of the Standard having future effective dates as indicated in the note
9、following the affected item. The prior text for requirements that have been revised and that have a future effective date are located after the Standard, and are preceded by a SUPERSEDED REQUIREMENTS notice. APRIL 16, 2012 UL 1022 tr1UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR
10、 DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 16, 2012 UL 1022 tr2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 16, 2012 1 UL 1022 Standard for Line Isolation Monitors First Edition March, 1973 Second Edition Ju
11、ly, 1979 Third Edition March, 1994 Fourth Edition June, 1998 Fifth Edition April 16, 2012 This ANSI/UL Standard for Safety consists of the Fifth Edition. The most recent designation of ANSI/UL 1022 as an American National Standard (ANSI) occurred on April 16, 2012. ANSI approval for a standard does
12、not include the Cover Page, Transmittal Pages, Title Page, or effective date information. Comments or proposals for revisions on any part of the Standard may be submitted to UL at any time. Proposals should be submitted via a Proposal Request in ULs On-Line Collaborative Standards Development System
13、 (CSDS) at http:/. ULs Standards for Safety are copyrighted by UL. Neither a printed nor electronic copy of a Standard should be altered in any way. All of ULs Standards and all copyrights, ownerships, and rights regarding those Standards shall remain the sole and exclusive property of UL. COPYRIGHT
14、 2012 UNDERWRITERS LABORATORIES INC. ANSI/UL 1022-2012UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL APRIL 16, 2012 LINE ISOLATION MONITORS - UL 1022 2 No Text on This PageUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR D
15、ISTRIBUTION WITHOUT PERMISSION FROM UL CONTENTS INTRODUCTION 1 Scope .5 2 General 5 2.1 Components .5 2.2 Units of measurement .6 2.3 Undated references .6 3 Glossary .6 4 Instructions and Drawings 7 CONSTRUCTION 5 Enclosure 7 5.1 General .7 5.2 Cast metal enclosures 8 5.3 Sheet metal enclosures .8
16、5.4 Nonmetallic enclosures 9 5.5 Ventilating openings .10 5.6 Covers .11 5.7 Glass panels 11 6 Electric Shock .12 7 Corrosion Protection .12 8 Field-Wiring System Connections 13 8.1 General 13 8.2 Equipment grounding connection 14 9 Internal Wiring .14 9.1 General 14 9.2 Wireways .15 9.3 Splices .15
17、 9.4 Barriers 15 9.5 Bushings .15 9.6 Strain relief .16 10 Bonding for Grounding 16 11 Components .17 11.1 Current-carrying parts .17 11.2 Insulating material 18 11.3 Lampholders and lamps .19 11.4 Meters 19 11.5 Printed-wiring boards .19 11.6 Switches 19 11.7 Protective devices 20 11.8 Alarm silenc
18、ing means 20 11.9 Audible signaling appliance 20 11.10 Mounting of components .20 11.11 Operating components .21 12 Spacings 21 13 Servicing and Maintenance 22 APRIL 16, 2012 LINE ISOLATION MONITORS - UL 1022 3UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PE
19、RMISSION FROM UL PERFORMANCE 14 General 23 15 Normal Operation Test 23 16 Sampling Circuit Supervision Test 25 17 Power Input Test .25 18 Leakage Current Measurements Test .25 19 Overvoltage and Undervoltage Test .30 19.1 Voltage operation 30 19.2 Undervoltage operation .30 20 Jarring Test 30 21 Tem
20、perature Test .31 22 Overload Test 34 22.1 Monitor .34 22.2 Separately energized circuits 34 23 Endurance Test 35 23.1 Monitor .35 23.2 Devices and separately energized circuits .35 24 Variable Ambient Temperature Test .35 25 Humidity Test 36 26 Electric Shock Current Test 36 27 Transient Tests .40
21、27.1 General .40 27.2 Externally-induced transients 40 27.3 Internally-induced transients .40 28 Dielectric Voltage-Withstand Test .41 29 Component Failure Test .42 30 Abnormal Operation Test 42 31 Test Switch Operation Test 42 MANUFACTURING AND PRODUCTION TESTS 32 General 42 33 Production-Line Leak
22、age Current Measurements Test .43 34 Production-Line Dielectric Voltage-Withstand Tests .43 MARKING 35 General 44 36 Supplementary .45 36.1 Installation drawing .45 36.2 Operating instructions .46 APPENDIX A Standards for ComponentsA1 APRIL 16, 2012 LINE ISOLATION MONITORS - UL 1022 4UL COPYRIGHTED
23、MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION OR DISTRIBUTION WITHOUT PERMISSION FROM UL INTRODUCTION 1 Scope 1.1 These requirements cover dynamic line isolation monitors and related supplementary indicating units for supervising isolated power-supply circuits in patient care areas of health care
24、 facilities, including inhalation-anesthetizing locations in accordance with the National Electrical Code, NFPA 70. 1.2 The detectors and supplementary indicating units are intended to be: a) Included as part of an isolated power-supply center for patient care locations of health care facilities; an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL10222012ULSTANDARDFORSAFETYLINEISOLATIONMONITORSFIFTHEDITIONREPRINTWITHREVISIONSTHROUGHANDINCLUDINGAUGUST32016

链接地址:http://www.mydoc123.com/p-1067262.html