UL 1017 CRD-2013 UL Standard for Safety Vacuum Cleaners Blower Cleaners and Household Floor Finishing Machines - Section Paragraph Reference 4 8 1 1 4 8A 5 29 Subject Motor Requir.pdf
《UL 1017 CRD-2013 UL Standard for Safety Vacuum Cleaners Blower Cleaners and Household Floor Finishing Machines - Section Paragraph Reference 4 8 1 1 4 8A 5 29 Subject Motor Requir.pdf》由会员分享,可在线阅读,更多相关《UL 1017 CRD-2013 UL Standard for Safety Vacuum Cleaners Blower Cleaners and Household Floor Finishing Machines - Section Paragraph Reference 4 8 1 1 4 8A 5 29 Subject Motor Requir.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared and published by Underwriters Laboratories Inc.(UL). It is normative for the a
2、pplicable UL Product Certification Program(s); however, it is currently notpart of the UL Standard(s) referenced below.Product Category (CCN): DMLWStandard Number: UL 1017Standard Title: Standard for Vacuum Cleaners, Blower Cleaners, and HouseholdFloor Finishing MachinesEdition Date: September 10, 2
3、010Edition Number: 8Section / Paragraph Reference: 4.8.1.1, 4.8A, 5.29Subject: Motor RequirementsDECISION:4.8 Motors4.8.1 General4.8.1.1 Motors shall comply with the Standard for Rotating Electrical Machines - General Requirements,UL 1004-1, or be evaluated in the end-use by the applicable requireme
4、nts of this end-product standard,and shall be of a type suitable for the particular application; see Clause 4.8A. They shall be capable ofcarrying the normal load (see Clause 5.2) without exceeding the permissible temperatures when theappliance is tested in accordance with the temperature test, Clau
5、se 5.8.Exception: A motor provided with integral insulation (e.g. epoxy coating) in lieu of slot liners shall alsocomply with the Standard for Systems of Insulating Materials - General, UL 1446, and the integralinsulation requirements specified in Clause 5.29.4.8A Motors4.8A.1 Motors having a NEMA f
6、rame size shall comply with the Standard for Motors and Generators,C22.2 No. 100 and the Standard for Rotating Electrical Machines - General Requirements, UL 1004-1.This includes fractional HP motors rated up to 1 HP (typically NEMA frame sizes 42, 48, or 56), andintegral HP motors rated 1 HP and gr
7、eater (typically NEMA frame sizes 140 - 449T).4.8A.2 Motors not enclosed, or partially enclosed, by the end product enclosure shall comply with theStandard for Motors and Generators, C22.2 No. 100 and the Standard for Rotating Electrical Machines -General Requirements, UL 1004-1.4.8A.3 Motors comple
8、tely enclosed within the end product enclosure shall comply with one of thefollowing:a) The Standard for Motors and Generators, C22.2 No. 100 and the Standard for RotatingElectrical Machines - General Requirements, UL 1004-1; orb) The Standard for Rotating Electrical Machines - General Requirements,
9、 UL 1004-1 exceptas noted in Table 26; orUL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULc) The motor shall comply with the following construction requirements and the applicableperformance requirements (when tested in conjunction with the end
10、 product), of this endproduct standard:1) Protection against corrosion, Clause 4.3.2) Terminal compartment, Clause 4.4.5.3) Internal wiring, Clause 4.6.4) Electrical Insulation, Clause 4.7.5) Motors, Clause 4.8.6) Capacitors, Clause 4.10.7) Spacings, Clause 4.13.8) Grounding, Clause 4.14.4.8A.4 A mo
11、tor located in an extra-low voltage circuit is evaluated for the risk of fire and personal injuryin accordance with the applicable requirements of this end product standard.Table 26 - Superseded requirements(See Clause 4.8A.3b)UL 1004-1 exempted requirement Superseded by the requirements in this end
12、-productstandardCurrent and Horsepower Relation Clause 4.13.1.10Cord-Connected Motors Clause 4.4.1Factory Wiring Terminals and Leads Clause 4.6Electrical Insulation Clause 4.7Non-Metallic Functional Parts Clauses 4.1, 4.7, and 4.8Solid-State Controls, 7.2 Clause 4.9Non-metallic enclosure thermal agi
13、ng, 9.1.4 Clauses 4.1 and 4.7Motor enclosure - Cast Metal Enclosures, Sheet MetalEnclosures, and Polymeric EnclosuresClause 4.1Grounding, and Grounding Identification Clause 4.14Ventilation Openings: only applicable where the openings areon surfaces considered to be the appliance enclosure.Clause 4.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便