《UL 1004-7 CRD-2016 UL Standard for Safety Electronically Protected Motors - Section Paragraph Reference 6 5 6 6 10 2 Subject Requirements for ECMs with electronic protection inten.pdf》由会员分享,可在线阅读,更多相关《UL 1004-7 CRD-2016 UL Standard for Safety Electronically Protected Motors - Section Paragraph Reference 6 5 6 6 10 2 Subject Requirements for ECMs with electronic protection inten.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULUNDERWRITERS LABORATORIES INC. CERTIFICATION REQUIREMENT DECISIONThis Certification Requirement Decision is prepared by UL LLC. It is normative for the applicable ULProduct Certification Program(
2、s); however, it is currently not part of the UL Standard(s) referencedbelow.Product Category (CCN): XDNW/7Standard Number: UL 1004-7Standard Title: Standard for Electronically Protected MotorsEdition Date: July 13, 2012Edition Number: 2Section / Paragraph Reference: 6.5, 6.6, 10.2Subject: Requiremen
3、ts for ECMs with electronic protection intended for fieldinstallationDECISION:(REVISED)2.1 Controls used to provide overheating protection for motors covered by this Standard shall comply withthe requirements for protective controls contained in the Standard for Automatic Electrical Controls forHous
4、ehold and Similar Use, Part 1: General Requirements, UL 60730-1 or the applicable requirements inSections 8A through 8I.6.1 With reference to 2.1, all performance testing required by the Standard for Automatic ElectricalControls for Household and Similar Use, Part 1: General Requirements, UL 60730-1
5、, on the control is tobe performed with the control connected as intended to the motor.Exception: A motor control shall only need comply with the requirements for operating controls in UL60730-1, if the motor coil complies with the locked rotor performance criteria in the Standard for ThermallyProte
6、cted Motors, UL 1004-3, with motor control disconnected from the motor coils, and the power supplyfor the motor control connected directly across a single motor coil or any combination of motor coilsconnected in parallel.6.2 Any test conducted on the control that does not result in an obvious inabil
7、ity of the motor to operateas intended, characterized by a cessation of rotation, shall not result in a temperature of the motorwindings in excess of the values specified in Table 32.12 of UL 1004-1. Cessation of rotation isconsidered to be independent of an inability to start.6.3 Any test conducted
8、 on the control that results in an obvious inability of the motor to operate asintended, characterized by a cessation of rotation, shall not result in a temperature of the motor windingsin excess of the values specified in Table 841A.1 of UL 1004-3. Cessation of rotation is considered to beindepende
9、nt of an inability to start.Exception: Any test conducted on the control used within a motor intended for field installation shall notresult in a temperature of the motor windings in excess of the values specified in Table 32.1 of UL 1004-1.6.4 Any abnormal test conducted on the electronic protectio
10、n circuit that terminates as a result of acomponent failure, that failure mode shall be evaluated in a manner consistent with the requirements ofUL 60730-1 to ensure that the result is reliable and consistent.6.5 Controls evaluated to provide required motor overtemperature protection shall provide t
11、he followingrequired safety functions when evaluated to the requirements of UL 60730-1:UL COPYRIGHTED MATERIAL NOT AUTHORIZED FOR FURTHER REPRODUCTION ORDISTRIBUTION WITHOUT PERMISSION FROM ULa) Locked rotor protection The control shall not allow motor temperatures in excess of theapplicable values
12、those specified in Table 841A.1 of UL 1004-3 under any test conditionrequired by UL 60730-1.b) Loss of phase (power supply phase not motor phase):1) Where loss of a power supply phase does not result in a cessation of rotation, thetemperature of the motor windings shall not exceed the applicable val
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UL10047CRD2016ULSTANDARDFORSAFETYELECTRONICALLYPROTECTEDMOTORSSECTIONPARAGRAPHREFERENCE6566102SUBJECTREQUIREMENTSFORECMSWITHELECTRONICPROTECTIONINTENPDF

链接地址:http://www.mydoc123.com/p-1067237.html