UFC 4-740-02-2006 FITNESS CENTERS《健身中心》.pdf
《UFC 4-740-02-2006 FITNESS CENTERS《健身中心》.pdf》由会员分享,可在线阅读,更多相关《UFC 4-740-02-2006 FITNESS CENTERS《健身中心》.pdf(103页珍藏版)》请在麦多课文档分享上搜索。
1、UFC 4-740-02 26 September 2006 UNIFIED FACILITIES CRITERIA (UFC) FITNESS CENTERS APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UFC 4-740-02 26 September 2006 UNIFIED FACILITIES CRITERIA (UFC) FITN
2、ESS CENTERS Any copyrighted material included in this UFC is identified at its point of use. Use of the copyrighted material apart from this UFC must have the permission of the copyright holder. U.S. ARMY CORPS OF ENGINEERS NAVAL FACILITIES ENGINEERING COMMAND (Preparing Activity) AIR FORCE CIVIL EN
3、GINEER SUPPORT AGENCY Record of Changes (changes are indicated by 1 . /1/) Change No. Date Location Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UFC 4-740-02 26 September 2006 FOREWORD The Unified Facilities Criteria (UFC) system is prescribed by
4、MIL-STD 3007 and provides planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD(AT may be self-serve (vending). Waiting/display Waiting area with seating
5、 and display. Public restrooms/phone Public restrooms (tied to gym capacity), telephone. Administrative Directors office Private office. Program managers offices Private offices (AF and Marine Corps) or workstations (Army and Navy). Administrative offices Workstations. Classrooms/training rooms Requ
6、ired program space. For AF facilities, if a Health and Wellness Center is attached to the Fitness Center, these rooms will be supplanted by the Health and Wellness Center classroom/training room. Copy/work/break room Copier, layout space, storage, small break area. Gymnasium Basketball/volleyball co
7、urt(s) NCAA-size court(s). Spectator seating Minimum of 200 seats, more as required and with additional courts. Storage/support Storage area with access to both the gym and to the outside if adjacent intramural fields are present. Unit PT/Group Exercise Group exercise room One large subdivideable ro
8、om with partitions (for classes and/or unit/command fitness training). Storage/support Storage area with access to Unit PT/group exercise room. Fitness Spaces Stretching/warm-up/cool-down Free/plate-loaded weights Selectorized (machine) weights Cardiovascular (cardio) equipment Usually one open spac
9、e; may use floor finishes to separate subspaces; may use alcoves; may use balconies/mezzanines. 1-3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UFC 4-740-02 26 September 2006 TABLE 1-1. FUNCTIONAL PROGRAM AREAS Functional Program Area Description
10、/Service Exceptions Fitness program managers office Private office adjacent to fitness assessment room and fitness spaces. May include fitness testing equipment. Marine Corps requires fitness testing equipment. Fitness assessment room Private office with desk, computer, and chairs for staff to meet
11、with customer adjacent to fitness spaces. Includes fitness testing equipment. Structured Activities Structured activity space Can be used as needed, i.e. for climbing wall, spinning, martial arts/boxing, other structured activity, or rolled into other functional areas as needed. Army requires this a
12、s a stand-alone space. Racquetball courts Sized and specified to include wally ball, squash, and handball. Spectator area/officiating Optional for Marine Corps. Required for AF and Army. Not supported by Navy. Locker Rooms Mens Locker Room Locker/changing area Shower/drying area Toilet area Womens L
13、ocker Room Locker/changing area Shower/drying area Toilet area Separate male/female facilities. Each locker room is divided into the three sub areas indicated. Sauna Separate male/female facilities. Optional for Army to have either sauna or steam room (see below). Optional for Air Force and Marine C
14、orps. Steam room Separate male/female facilities. Optional for Army to have either steam room or sauna (see above). Optional for Air Force. Not supported by Marine Corps. Hot tub Optional. May be separate male/female or may be combined. Not supported by Army. Convertible locker space Optional for Ar
15、my and Air Force. Optional for Marine Corps only in Large or Extra Large Facilities. Not supported by Navy. This is locker/changing space that can be used for additional male or female space to accommodate tournaments and/or changing demographics. It is a separate room between the male and female lo
16、cker rooms with double-locked doors into each. Support Areas Laundry For towels and uniforms. Adjacent to receiving (if laundry service used) and control desk, if possible. 1-4 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UFC 4-740-02 26 September
17、 2006 TABLE 1-1. FUNCTIONAL PROGRAM AREAS Functional Program Area Description/Service Exceptions Receiving and equipment repair Receiving, storage, and repair (with tool storage). Adjacent to loading dock or double exterior doors and the fitness spaces. Area to hold (if necessary), assemble, and rep
18、air equipment. Also store overflow from the equipment issue (i.e. seasonal items). Lockable storage with a sub area of additional secure storage. Additional programmatic storage Optional storage for additional, optional program equipment (i.e. boxing ring). May be combined with receiving/equipment r
19、epair. Other Program Areas Pool Note that pools and natatoriums are a different category code. If a pool/natatorium is desired, it will affect the adjacencies and traffic flow within the building. See Figure 2.3 for these adjacencies. For space and technical criteria for pools/natatoriums, refer to
20、the following additional documents: Army, US Army Community and Family Support Center (CFSC), Navy and Marine Corps. NAVFAC P-80, Facility Planning Criteria for Navy and Marine Corps Shore Installations CCN 740-53 and 750; and Air Force. UFC 4-750-07F, Aquatic Facilities. Track Army requiredspace fo
21、r indoor track may be used for additional cardio space in temperate locations with approval of CFSC. Air Force requiredInstallation determines indoor track or outdoor track. Navy and Marine Corpsoptional. Navy determines permissibility by center size and climate. Massage room Optional room for massa
22、ge. Not supported by Navy. Physical therapy/rehabilitation training Optional. Similar functional requirements to fitness assessment office. Not supported by Navy. Air Force recommends locating this function in the HAWC (see Table 1-2). Expanded retail Optional. Retail area for clothes, sports equipm
23、ent. Not supported by Navy. Expanded juice bar Optional. A separate counter in lobby space. May be contract space. Not supported by Navy. Family changing room Required for Army and Navy if co-located with a pool/natatorium. Optional for Air Force and Marine Corps. Single-person locker room with show
24、er, lavatory, and toiletfamily member accompanies child. Adjacent to locker area and pool (if provided). 1-5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UFC 4-740-02 26 September 2006 TABLE 1-1. FUNCTIONAL PROGRAM AREAS Functional Program Area De
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UFC4740022006FITNESSCENTERS 健身 中心 PDF