《UFC 4-133-01N CHANGE 4 AND 5-2007 NAVY AIR TRAFFIC CONTROL FACILITIES [Superseded NAVY MIL-HDBK-1024 1 CANC NOTICE 1 NAVY MIL-HDBK-1024 1].pdf》由会员分享,可在线阅读,更多相关《UFC 4-133-01N CHANGE 4 AND 5-2007 NAVY AIR TRAFFIC CONTROL FACILITIES [Superseded NAVY MIL-HDBK-1024 1 CANC NOTICE 1 NAVY MIL-HDBK-1024 1].pdf(72页珍藏版)》请在麦多课文档分享上搜索。
1、UFC 4-133-01N 24 February 2005 Including change 4 and 5, 30 July 2007 UNIFIED FACILITIES CRITERIA (UFC) NAVY AIR TRAFFIC CONTROL FACILITIES APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UFC 4-133-
2、01N 24 February 2005 Including change 4 and 5, 30 July 2007 UNIFIED FACILITIES CRITERIA (UFC) DESIGN: NAVY AIR TRAFFIC CONTROL FACILITIES Any copyrighted material included in this UFC is identified at its point of use. Use of the copyrighted material apart from this UFC must have the permission of t
3、he copyright holder. U.S. ARMY CORPS OF ENGINEERS NAVAL FACILITIES ENGINEERING COMMAND (Preparing Activity) AIR FORCE CIVIL ENGINEER SUPPORT AGENCY Record of Changes (changes are indicated by 1 . /1/) Change No. Date Location 1 7 March 2007 Figure 1, page 38 2 7 March 2007 Paragraph 2.5, page 15 3 2
4、0 June 2007 Editorial corrections throughout. 4 30 July 2007 Paragraph 2-5.3.11 and 2-5.3.12, page 18 5 30 July 2007 Paragraph 2-5.1, page 15 This UFC supersedes MIL-HDBK-1024/1, in part, dated February 1994. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from I
5、HS-,-,-UFC 4-133-01N 24 February 2005 Including change 4 and 5, 30 July 2007 FOREWORD The Unified Facilities Criteria (UFC) system is prescribed by MIL-STD 3007 and provides planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments,
6、 the Defense Agencies, and the DoD Field Activities in accordance with USD(AT requirements must be confirmed by Naval Electronics Systems Security Engineering Center (NESSEC). f. Facility and restroom must conform to the UFAS. 2-3.3.1 Windows. Do not provide windows in operations, NTDS/ACDS system,
7、and electronic equipment/maintenance rooms. Provide insulated glazing for noise reduction in administrative areas. See Paragraph 3-6.3.6. 2-3.4 Mechanical Requirements. Design the mechanical system to meet the criteria in Paragraphs 3-4, UFC 3-420-01 Design: Plumbing Systems, and MIL-HDBK 1003/3 Hea
8、ting, Air Conditioning, and Dehumidification Systems. Provide: a. Automatic thermostatic control. b. A four-pipe chilled/hot water distribution system with separate air handlers for each zone or dehumidifying system to work in conjunction with the air conditioning system. c. Capability for future ex
9、pansion of the heating, ventilation, and air conditioning (HVAC) system. Use piping designed for low friction and velocity losses at the maximum flows expected. 2-3.4.1 Air Conditioning. Provide: a. Two parallel piped air-cooled chillers, each designed for 60 percent of the total building-cooling lo
10、ad. Alternate operation of chillers automatically, on a regular basis, when load is less than 60 percent. Consider cold storage to minimize power peaks. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UFC 4-133-01N 24 February 2005 Including change 4
11、 and 5, 30 July 2007 10 b. One chilled water circulation pump for each chiller plus a manifold spare pump. Design chiller circuitry so that the pump must operate and water flow before the chiller is energized. The spare pump may be manually operated. Provide secondary chilled water loops with three-
12、way valves at coils in each circuit to result in constant flow through chiller. c. Divide the building into three cooling zones: administrative areas, operations areas, and the equipment areas. Provide separate air handlers and ducting systems for each zone. Provide sound attenuators for all supply
13、ductwork. Consider more than one air handler for large zones. d. Provide two air handlers for the operations and electronic equipment rooms. Design the air handler controls to regulate the units as primary and secondary with each unit alternating as the primary. Provide air handlers capable of contr
14、olling humidity, equipped with electric heat, and specifically designed for computer room applications. See MIL-HDBK-1012/1, Electronic Facilities Engineering. 2-3.4.2 Heating Provide fuel oil or gas operated boiler heating system designed to accommodate the largest heating load anticipated. Provide
15、 two circulation pumps, each designed for 100 percent of the total building-heating load. Design the pump controls to regulate the pumps as primary and secondary with each pump alternating as the primary. 2-3.5 Electrical Requirements. 2-3.5.1 Uninterrupted Power Supply (UPS). Provide non-redundant
16、UPS with maintenance bypass switchin accordance with Paragraph 3-5.2.3. Use anticipated load to determine the size of UPS. Use a separate plumbing and electrical chase that extends from the ground floor to the cable access level. 2-3.5.2 Emergency Electrical Power. Provide an emergency generator wit
17、h automatic starting and switching capability as described in Paragraph 3-5.2. Provide emergency power to: a. All loads as required by NFPA-101. b. Electronic equipment in operations and with maintenance bypass switch. Provided by IHSNot for ResaleNo reproduction or networking permitted without lice
18、nse from IHS-,-,-UFC 4-133-01N 24 February 2005 Including change 4 and 5, 30 July 2007 11 c. Building mechanical systems supporting electronic equipment. d. Exterior security lighting and security systems. 2-3.5.3 400-Hz Power. Provide 400-Hz (Hz) power in accordance with Paragraph 3-5.2.4, when req
19、uired by the FRS. 2-3.6 Security. The RATCF is normally located within restricted areas that meet the minimum-security measures for external security. When the facility is located within a restricted area of a lower level of security or is located remote and outside of an established restricted area
20、. Provide additional measures to meet the minimum security requirements for the level of security assigned to the facility. Security at the main entrance usually requires a single entry point with visitor control. Remote locks, video cameras, card readers, and/or keypads may be required by NISCOM as
21、 components of the IDS. The level of security and the designers responsibility for particular security elements will be designated in the IDSEP. See Paragraph 3-6. Provide: a. Electronic cipher door locks at all access points to the IFR room and electronic equipment rooms. b. Exterior doors in the I
22、FR room and electronic equipment rooms with no access hardware on the outside. c. Closed circuit TV (CCTV). d. Security fencing and guard post for facilities located outside the secure area of the Naval installation. e. Personnel identification, visitor check-in, and control system to control ingres
23、s and egress. 2-3.7 Additional Design Criteria. Refer to Chapter 3, “General Design Criteria“ for facility design requirements not addressed above. 2-4 JOINT CONTROL FACILITY (JCF). 2-4.1 Function. A combined ATCF and ROC/FACSFAC that may provide airport traffic control, low approach and landing, te
24、rminal area control, and special use airspace control services. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UFC 4-133-01N 24 February 2005 Including change 4 and 5, 30 July 2007 12 2-4.2 Location. Locate the JCF building adjacent to the ATCT wher
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UFC413301NCHANGE4AND52007NAVYAIRTRAFFICCONTROLFACILITIESSUPERSEDEDNAVYMILHDBK10241CANCNOTICE1NAVYMILHDBK10241PDF

链接地址:http://www.mydoc123.com/p-1066961.html