UFC 3-301-01 CHANGE 3-2012 STRUCTURAL ENGINEERING.pdf
《UFC 3-301-01 CHANGE 3-2012 STRUCTURAL ENGINEERING.pdf》由会员分享,可在线阅读,更多相关《UFC 3-301-01 CHANGE 3-2012 STRUCTURAL ENGINEERING.pdf(100页珍藏版)》请在麦多课文档分享上搜索。
1、UFC 3-301-01 27 January 2010 With Change 3, 31 January 2012 UNIFIED FACILITIES CRITERIA (UFC) STRUCTURAL ENGINEERING APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UFC 3-301-01 27 January 2010 With
2、 Change 3, 31 January 2012 UNIFIED FACILITIES CRITERIA (UFC) STRUCTURAL ENGINEERING Any copyrighted material included in this UFC is identified at its point of use. Use of the copyrighted material apart from this UFC must have the permission of the copyright holder. U.S. ARMY CORPS OF ENGINEERS NAVA
3、L FACILITIES ENGINEERING COMMAND (Preparing Activity) AIR FORCE CIVIL ENGINEER SUPPORT AGENCY Record of Changes (changes are indicated by 1 . /1/) Change No. Date Location 1 20 July 2010 Modified Appendix G, Table 17 regarding Haiti; modified paragraph 2-1.2.1 2 31 January 2011 Modified to conform t
4、o the adoption of IBC 2009; other minor revisions 3 31 January 2012 Modified to update seismic data for Djibouti, Africa This UFC supersedes UFC 3-300-10N, dated May 2005; UFC 3-310-01, dated 25 May 2005; UFC 3-310-02A, dated 1 March 2005; UFC 3-310-05A, dated 1 March 2005; UFC 3-310-07A, dated 19 J
5、une 2006; UFC 3-320-01A, dated 1 March 2005; UFC 3-320-02A, dated 1 March 2005; UFC 3-320-04A, dated 1 March 2005; UFC 3-320-05A, dated 1 March 2005; UFC 3-330-01A, dated 1 March 2005. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UFC 3-301-01 27 J
6、anuary 2010 With Change 3, 31 January 2012 FOREWORD The Unified Facilities Criteria (UFC) system is prescribed by MIL-STD 3007 and provides planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD
7、 Field Activities in accordance with USD(AT either from wind or seismic; or be isolated to Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UFC 3-301-01 27 January 2010 With Change 3, 31 January 2012 4 ensure that they are not susceptible to damage. M
8、asonry and other brittle wall systems are particularly susceptible to damage if not properly integrated into the design to ensure that they can adequately resist the stresses resulting from the building deformations or are effectively isolated to prevent damage. Exception: Reinforced concrete frame
9、members not designed as part of the seismic lateral force-resisting system shall comply with Section 21.9 of ACI 318. All structural vertical load bearing wall elements shall be considered to be part of the lateral force-resisting system. All applicable provisions of UFC 3-310-04 Table B-2 shall app
10、ly. 2-1.2.2 1604.3.1 - Deflections Replacement Deflections of structural members shall not exceed the more restrictive of the limitations of Sections 1604.3.2 through 1604.3.5 or those permitted by Table 1604.3, or Table 2-1 of UFC 3-301-01. 2-1.2.3 1604.3.6 - Limits Replacement Deflection of struct
11、ural members over span, l, shall not exceed that permitted by Table 1604.3 or Table 2-1 of UFC 3-301-01. TABLE 2-1 - LATERAL DEFLECTION LIMITS FOR FRAMING SUPPORTING EXTERIOR WALL FINISHESa,b,cBrick veneer L/600 Stucco L/360 Exterior Insulation Finish Systems L/240 Cement board L/360 Stone Masonry V
12、ERIFY WITH STONE SUPPLIER Plywood and Wood-Based Structural-Use Panels L/240 Gypsum sheathing L/240 Metal or vinyl siding L/240 Notes to Table 2-1, “LATERAL DEFLECTION LIMITS FOR FRAMING SUPPORTING EXTERIOR WALL FINISHES” a. Lateral deflection limits under seismic or wind loads Provided by IHSNot fo
13、r ResaleNo reproduction or networking permitted without license from IHS-,-,-UFC 3-301-01 27 January 2010 With Change 3, 31 January 2012 5 b. The wind load is permitted to be taken as 0.7 times the “component and cladding” loads for the purpose of determining the deflection limits herein. c. For can
14、tilevered members, L shall be taken as twice the length of the cantilever. 2-1.2.4 1604.5 - Occupancy Category Replacement Buildings shall be assigned an occupancy category in accordance with Table 2-2 of UFC 3-301-01. Importance factors for snow load, 2 wind load, seismic load, and ice /2/ for each
15、 occupancy category are also shown in Table 2-2 of UFC 3-301-01. Note: IBC section 1604.5.1 shall remain in effect as written. 2-1.2.5 Table 1604.5 Replacement Replace Table 1604.5 of the IBC with Table 2-2 of this UFC. (All references in the IBC to Table 1604.5 shall be interpreted as a reference t
16、o Table 2-2 of this UFC.) Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UFC 3-301-01 27 January 2010 With Change 3, 31 January 2012 6 2 TABLE 2-2 - OCCUPANCY CATEGORY OF BUILDINGS AND OTHER STRUCTURES Occupancy Category Nature of Occupancy Seismic
17、Factor IESnow Factor ISWind Factor IWIce Factor IiI Buildings and other structures that represent a low hazard to human life in the event of failure, including, but not limited to: Agricultural facilities Certain temporary facilities Minor storage facilities 1.00 0.8 0.87a0.80 II Buildings and other
18、 structures except those listed in Categories I, III, IV and V 1.00 1.00 1.00 1.00 III Buildings and other structures that represent a substantial hazard to human life or represent significant economic loss in the event of failure, including, but not limited to: Buildings and other structures whose
19、primary occupancy is public assembly with an occupant load greater than 300 people Buildings and other structures containing elementary school, secondary school, or daycare facilities with an occupant load greater than 250 Buildings and other structures with an occupant load greater than 500 Group I
20、-2 occupancies with an occupant load of 50 or more resident patients, but not having surgery or emergency treatment facilities Group I-3 occupancies Power-generating stations; water treatment facilities for potable water, waste water treatment facilities, and other public utility facilities that are
21、 not included in Categories IV and V Buildings and other structures not included in Categories IV and V containing sufficient quantities of toxic, flammable, or explosive substances to be dangerous to the public if released Facilities having high-value equipment, as designated by the authority havin
22、g jurisdiction 1.25 1.10 1.15 1.25 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-UFC 3-301-01 27 January 2010 With Change 3, 31 January 2012 7 IV Buildings and other structures designed as essential facilities, including, but not limited to: Group
23、I-2 occupancies having surgery or emergency treatment facilities Fire, rescue, and police stations, and emergency vehicle garages Designated earthquake, hurricane, or other emergency shelters Designated emergency preparedness, communication, and operation centers, and other facilities required for e
24、mergency response Emergency backup power-generating facilities required for primary power for Category IV Power-generating stations and other utility facilities required for primary power for Category IV, if emergency backup power generating facilities are not available Structures containing highly
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- UFC330101CHANGE32012STRUCTURALENGINEERINGPDF

链接地址:http://www.mydoc123.com/p-1066929.html