SMPTE ST 430-16-2017 D-Cinema Operations C Extended Facility List Message.pdf
《SMPTE ST 430-16-2017 D-Cinema Operations C Extended Facility List Message.pdf》由会员分享,可在线阅读,更多相关《SMPTE ST 430-16-2017 D-Cinema Operations C Extended Facility List Message.pdf(35页珍藏版)》请在麦多课文档分享上搜索。
1、Approved July 14, 2017 Copyright 2017 by THE SOCIETY OF MOTION PICTURE AND TELEVISION ENGINEERS 3 Barker Avenue., White Plains, NY 10601 (914) 761-1100 SMPTE ST 430-16:2017 SMPTE STANDARD D-Cinema Operations Extended Facility List Message Page 1 of 35 pages Table of Contents 1 Scope 3 2 Conformance
2、Notation 3 3 Normative References 4 4 Overall 5 4.1 Schema 5 4.2 Instance 5 4.3 FLM Document 5 5 Structure 6 5.1 General 6 5.2 FacilityListMessageType 6 5.3 FacilityInfoType 7 5.4 FacilityCapabilitiesType 9 5.5 AuditoriumType 10 5.6 AuditoriumCapabilitiesType 12 5.7 SuiteType 16 5.8 NonSecurityDevic
3、eList 17 5.9 DeviceType 17 5.10 DeviceCapabilitiesType 19 5.11 AddressListType 21 5.12 ContactType 22 5.13 Digital3DsystemType 23 5.14 DeliveryMethodType 24 5.15 AddressType 25 5.16 EmailType 26 5.17 PhysicalType 26 5.18 ModemType 27 5.19 NetworkType 27 5.20 SatelliteDeliveryType 27 5.21 ComponentTy
4、pe 28 SMPTE ST 430-16:2017 Page 2 of 35 pages 5.22 WatermarkingType 29 5.23 ScopedStringType 30 5.24 EmailAddressType 30 5.25 ISO3166CountryCode 31 5.26 LuminanceUnitEnum 31 5.27 LengthUnitEnum 31 Annex A Consolidated Schema (Informative) 33 Annex B Example Instance (Informative) 34 Bibliography 35
5、Foreword SMPTE (the Society of Motion Picture and Television Engineers) is an internationally-recognized standards developing organization. Headquartered and incorporated in the United States of America, SMPTE has members in over 80 countries on six continents. SMPTEs Engineering Documents, includin
6、g Standards, Recommended Practices, and Engineering Guidelines, are prepared by SMPTEs Technology Committees. Participation in these Committees is open to all with a bona fide interest in their work. SMPTE cooperates closely with other standards-developing organizations, including ISO, IEC and ITU.
7、SMPTE Engineering Documents are drafted in accordance with the rules given in its Standards Operations Manual. This SMPTE Engineering Document was prepared by Technology Committee 21DC. Intellectual Property At the time of publication no notice had been received by SMPTE claiming patent rights essen
8、tial to the implementation of this Engineering Document. However, attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. SMPTE shall not be held responsible for identifying any or all such patent rights. Introduction This section is enti
9、rely informative and does not form an integral part of this document. To issue D-Cinema Packages and corresponding Key Delivery Messages, it is necessary to collect information on the devices present at the target exhibition facility, e.g. digital certificates, 3D capabilities, etc. SMPTE ST 430-7:2
10、008, which specifies a Facility List Message (FLM) structure for this purpose, has been superseded in practice by ad-hoc solutions. This document updates SMPTE ST 430-7:2008 to specify an Extended FLM structure, which builds on the latter. As depicted in Figure 1, each Extended FLM instance contains
11、 information on a single facility, which houses multiple auditoriums and devices. Devices can be associated with either the facility as a whole or with each auditorium individually, where they are grouped into playback suites. Multiple components software, hardware and firmware can be associated wit
12、h each device. SMPTE ST 430-16:2017 Page 3 of 35 pages Figure 1: Extended Facility List Message Structure Specific capabilities, e.g. 3D playback, can be associated with facilities, auditoriums and devices. This allows, for instance, a capability enabled by the combination of multiple devices to be
13、associated with an auditorium. This specification defines a number of capabilities, and allows other specifications to easily define additional capabilities as needed. 1 Scope This document specifies the Extended Facility List Message structure, which allows information on the equipment deployed at
14、a D-Cinema facility to be exchanged between parties for the purpose of issuing D-Cinema Packages, as specified in SMPTE ST 429-2, and corresponding Key Delivery Messages, as specified in ST 430-1. 2 Conformance Notation Normative text is text that describes elements of the design that are indispensa
15、ble or contains the conformance language keywords: “shall“, “should“, or “may“. Informative text is text that is potentially helpful to the user, but not indispensable, and can be removed, changed, or added editorially without affecting interoperability. Informative text does not contain any conform
16、ance keywords. All text in this document is, by default, normative, except: the Introduction, any section explicitly labeled as “Informative“ or individual paragraphs that start with “Note:” F L M ( )F a c i l i t y i n f o r m a t i o n ( )C a p a b i l i t i e s ( )D e v i c e ( )A u d i t o r i u
17、 m ( )C a p a b i l i t i e s ( )S u i t e ( )D e v i c e ( )N o n S e c u r i t y D e v i c e ( )SMPTE ST 430-16:2017 Page 4 of 35 pages The keywords “shall“ and “shall not“ indicate requirements strictly to be followed in order to conform to the document and from which no deviation is permitted. T
18、he keywords, “should“ and “should not“ indicate that, among several possibilities, one is recommended as particularly suitable, without mentioning or excluding others; or that a certain course of action is preferred but not necessarily required; or that (in the negative form) a certain possibility o
19、r course of action is deprecated but not prohibited. The keywords “may“ and “need not“ indicate courses of action permissible within the limits of the document. The keyword “reserved” indicates a provision that is not defined at this time, shall not be used, and may be defined in the future. The key
20、word “forbidden” indicates “reserved” and in addition indicates that the provision will never be defined in the future. A conformant implementation according to this document is one that includes all mandatory provisions (“shall“) and, if implemented, all recommended provisions (“should“) as describ
21、ed. A conformant implementation need not implement optional provisions (“may“) and need not implement them as described. Unless otherwise specified, the order of precedence of the types of normative information in this document shall be as follows: Normative prose shall be the authoritative definiti
22、on; Tables shall be next; then formal languages; then figures; and then any other language forms. 3 Normative References The following standards contain provisions which, through reference in this text, constitute provisions of this engineering document. At the time of publication, the editions indi
23、cated were valid. All standards are subject to revision, and parties to agreements based on this engineering document are encouraged to investigate the possibility of applying the most recent edition of the standards indicated below. Internet Assigned Numbers Authority (1987). Eggert, P. and A. Olso
24、n, “Sources for Time Zone and Daylight Saving Time Data“ (ftp:/ftp.iana.org/tz/code/tz-link.htm) SMPTE ST 430-1:2009, D-Cinema Operations Key Delivery Message SMPTE ST 430-2:2006, D-Cinema Operations Digital Certificate. SMPTE ST 428-12:2013, D-Cinema Distribution Master Common Audio Channels and So
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SMPTEST430162017DCINEMAOPERATIONSCEXTENDEDFACILITYLISTMESSAGEPDF

链接地址:http://www.mydoc123.com/p-1047052.html