SMPTE ST 425-1-2017 Source Image Format and Ancillary Data Mapping for the 3 Gb s Serial Interface.pdf
《SMPTE ST 425-1-2017 Source Image Format and Ancillary Data Mapping for the 3 Gb s Serial Interface.pdf》由会员分享,可在线阅读,更多相关《SMPTE ST 425-1-2017 Source Image Format and Ancillary Data Mapping for the 3 Gb s Serial Interface.pdf(32页珍藏版)》请在麦多课文档分享上搜索。
1、 Copyright 2017 by THE SOCIETY OF MOTION PICTURE AND TELEVISION ENGINEERS 445 Hamilton Avenue, White Plains, NY 10601 (914) 761-1100 Approved October 23, 2017 Table of Contents Page 1 Scope . 3 2 Conformance Notation . 3 3 Normative References 4 4 Level A Direct Mapping of Source Image Formats . 5 4
2、.1 20-Bit Virtual Interface . 6 4.2 Virtual Interface Data Stream Mappings 13 5 Level B Mapping of SMPTE ST 372 Dual- Link 23 5.1 SMPTE ST 372 Dual Link Mapping 24 6 Level B 2 x SMPTE ST 292 -1 (HD-SDI) Dual-Stream Mapping . 26 6.1 2 x SMPTE ST 292-1 (HD-SDI) Dual Stream Mapping 26 7 Levels of Opera
3、tion (Informative) 28 Annex A Level A Mapping Compared to Level B Mapping (Informative) . 29 A.1 Level A 10-bit Multiplex to a SMPTE ST 424 Interface 29 A.2 Level B 10-bit Multiplex to a SMPTE ST 424 Interface 29 Annex B Derivation of 32-Channel Audio Multiplexing Restrictions for Level A Direct Map
4、pings (Informative) . 30 Bibliography (Informative) 32 Page 1 of 32 pages SMPTE ST 425-1:2017 Revision of SMPTE ST 425-1:2014 SMPTE STANDARD Source Image Format and Ancillary Data Mapping for the 3 Gb/s Serial Interface SMPTE ST 425-1:2017 Page 2 of 32 pages Foreword SMPTE (the Society of Motion Pic
5、ture and Television Engineers) is an internationally-recognized standards developing organization. Headquartered and incorporated in the United States of America, SMPTE has members in over 80 countries on six continents. SMPTEs Engineering Documents, including Standards, Recommended Practices, and E
6、ngineering Guidelines, are prepared by SMPTEs Technology Committees. Participation in these Committees is open to all with a bona fide interest in their work. SMPTE cooperates closely with other standards-developing organizations, including ISO, IEC and ITU. SMPTE Engineering Documents are drafted i
7、n accordance with the rules given in its Standards Operations Manual. SMPTE ST 425-1 was prepared by Technology Committee 32NF. Intellectual Property At the time of publication no notice had been received by SMPTE claiming patent rights essential to the implementation of this Standard. However, atte
8、ntion is drawn to the possibility that some of the elements of this document may be the subject of patent rights. SMPTE shall not be held responsible for identifying any or all such patent rights. Introduction This section is entirely informative and does not form an integral part of this Engineerin
9、g Document. SMPTE ST 292-1 was originally developed to provide a serial digital connection between HDTV equipment operating largely with 10-bit YCBCR 4:2:2 signals to a maximum frame rate of 30 frames per second. Over time, SMPTE ST 292-1 applications were expanded to include larger picture formats,
10、 higher refresh rates and to provide support for RGB and 12-bit source signal formats and the carriage of packetized data. The total data rate required to support these additional applications is 2.970 Gb/s or 2.970/1.001 Gb/s and the digital interface used to carry these payloads has been realized
11、using a dual-link structure as defined in SMPTE ST 372. This standard defines the mapping of various source image formats onto a single link serial digital interface operating at a nominal rate of 3 Gb/s. SMPTE ST 425-1:2017 Page 3 of 32 pages 1 Scope This standard defines three mapping formats: Lev
12、el A, Level B Dual-Link mapping and Level B Dual-Stream mapping as described below; Level A specifies: The direct mapping of various uncompressed video image formats as defined in Table 1; The direct mapping of packetized data; The carriage of ancillary data such as the audio data, the audio control
13、 packets, the payload ID, the time code, etc.; into a serial digital interface operating at a nominal rate of 3 Gb/s. Level B Dual-Link mapping specifies: The mapping of the SMPTE ST 372 Dual Link interface (Dual-Link mapping) as defined in Table 13 into a serial digital interface operating at a nom
14、inal rate of 3 Gb/s. Level B Dual-Stream mapping specifies: The mapping of 2 x SMPTE ST 292-1 (HD-SDI) interfaces (Dual-Stream mapping) as defined in Table 14 into a serial digital interface operating at a nominal rate of 3 Gb/s. Informative Annex A provides further details on the differences betwee
15、n Level A and Level B mapping. Uncompressed video image formats or packetized data, and all applicable ancillary data such as the audio data, the audio control packets, the payload ID, the time code, etc. are mapped into SMPTE ST 372 Dual Link and 2 x SMPTE ST 292-1 interfaces prior to mapping into
16、the virtual interfaces. It is not necessary for implementations to include support for all formats defined in Table 1, Table 13 and Table 14 to conform to this standard. Implementers are encouraged to indicate supported formats in commercial publications. 2 Conformance Notation Normative text is tex
17、t that describes elements of the design that are indispensable or contains the conformance language keywords: “shall“, “should“, or “may“. Informative text is text that is potentially helpful to the user, but not indispensable, and can be removed, changed, or added editorially without affecting inte
18、roperability. Informative text does not contain any conformance keywords. All text in this document is, by default, normative, except: the Introduction, any section explicitly labeled as “Informative“ or individual paragraphs that start with “Note:” The keywords “shall“ and “shall not“ indicate requ
19、irements strictly to be followed in order to conform to the document and from which no deviation is permitted. The keywords, “should“ and “should not“ indicate that, among several possibilities, one is recommended as particularly suitable, without mentioning or excluding others; or that a certain co
20、urse of action is preferred but not necessarily required; or that (in the negative form) a certain possibility or course of action is deprecated but not prohibited. The keywords “may“ and “need not“ indicate courses of action permissible within the limits of the document. The keyword “reserved” indi
21、cates a provision that is not defined at this time, shall not be used, and may be defined in the future. The keyword “forbidden” indicates “reserved” and in addition indicates that the provision will never be defined in the future. SMPTE ST 425-1:2017 Page 4 of 32 pages A conformant implementation a
22、ccording to this document is one that includes all mandatory provisions (“shall“) and, if implemented, all recommended provisions (“should“) as described. A conformant implementation need not implement optional provisions (“may“) and need not implement them as described. Unless otherwise specified,
23、the order of precedence of the types of normative information in this document shall be as follows: Normative prose shall be the authoritative definition; Tables shall be next; followed by formal languages; then figures; and then any other language forms. 3 Normative References The following standar
24、ds contain provisions which, through reference in this text, constitute provisions of this standard. At the time of publication, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this standard are encouraged to investigate the possibility of
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SMPTEST42512017SOURCEIMAGEFORMATANDANCILLARYDATAMAPPINGFORTHE3GBSSERIALINTERFACEPDF

链接地址:http://www.mydoc123.com/p-1047011.html