SMPTE RP 133-1991 Specifications for Medical Diagnostic Imaging Test Pattern for Television Monitors and Hard-Copy Recording Cameras《电视监视器和截屏图录制摄像机医疗诊断成像试验模式规范》.pdf
《SMPTE RP 133-1991 Specifications for Medical Diagnostic Imaging Test Pattern for Television Monitors and Hard-Copy Recording Cameras《电视监视器和截屏图录制摄像机医疗诊断成像试验模式规范》.pdf》由会员分享,可在线阅读,更多相关《SMPTE RP 133-1991 Specifications for Medical Diagnostic Imaging Test Pattern for Television Monitors and Hard-Copy Recording Cameras《电视监视器和截屏图录制摄像机医疗诊断成像试验模式规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、1 ScopeThis practice describes the format, dimensions, andcontrast required to make diagnostically significantmeasurements of the display and camera systemresolution for both digital and analog monochromesignal sources. (See note.) The practice providesusers of medical diagnostic imaging systems wit
2、h acomprehensive test pattern for day-to-day operationalchecks and adjustments of focus, brightness andcontrast, resolution response, mid-band streaking,uniformity, and linearity of viewing monitors and hard-copy recordings. This practice is not intended to cre-ate a standard for image characteristi
3、cs such asresolution, geometry and linearity, uniformity, phos-phor defects, etc. However, use of the pattern isencouraged as an appropriate tool for evaluating themeasurement and specification of such image char-acteristics.2 Description2.1 PatternA reproduction of the test pattern is shown in figu
4、re 1.Figure 2 is a drawing of the pattern for reference tothe following text:2.2 BackgroundThe background is presented at 50% of maximumwhite to obtain an approximate average picture level(APL) of 50% (figure 2 1).2.3 Crosshatch patternThis pattern allows verification of linearity, either byusing a
5、straightedge or by overlaying or projecting aperfect reference image (Ball chart) (figure 2 2).2.4 Resolution patternThree zones of vertical and horizontal, high-contrastbar patterns are placed in five locations (four cornersand the center). The modulation depth of the patternis 100%. Placement of t
6、he patterns facilitates com-parison of the resolution in the center and in thecorners of the screen (figure 2 3). A detailed view ofthe resolution pattern is shown in figure 3.2.5 Low-contrast imaging resolutionThree zones of vertical and horizontal, low-contrast,equally-spaced bars are located next
7、 to the patternsdescribed in 2.4. The modulation depth of these areasis 1%, 3%, and 5%. This is the most sensitive test forvarious types of imaging noise (figure 2 4).2.6 Gray step patternBlocks of specified signal amplitude, representing 0%to 100% of the input signal in steps of 10%, allowmeasureme
8、nts of the response characteristics of theviewing monitors and hard copy (figure 2 5).2.6.1 Small-contrast changesSmall-contrast changes of 5% of the input signal aresuperimposed on a 0% background, and a 95% valueis superimposed on a 100% maximum signal back-ground to allow quick verification that
9、all availablegray-scale information can be presented in the imageto be displayed (figure 2 6).2.7 White window and black windowDuring display of these patterns, the display or record-ing device signal stays relatively long in one state(black or white). These large areas of maximum con-trast facilita
10、te detection of mid-band streaking (poorlow-frequency response), video amplifier ringing orovershoot, deflection interference, and halo (figure 27 and 8).Specifications for Medical Diagnostic Imaging Test Pattern forTelevision Monitors andHard-Copy Recording CamerasRevision of RP 133-1986RP 133-1991
11、SMPTE RECOMMENDED PRACTICEPage 1 of 6 pagesApproved March 1, 1991Copyright 1991 by theSOCIETY OF MOTION PICTURE AND TELEVISION ENGINEERS595 W. Hartsdale Ave., White Plains, NY 10607(914) 761-1100REAFFIRMED 1999 Figure 1 Video hard-copy camera image of test patternFigure 2 Schematic drawing of test p
12、attern in a square formatRP 133-1991Page 2 of 6 pages2.8 Picture borderA line is placed around the outside of the pattern thatdefines the full extent of the pattern (figure 2 9).3 Format3.1 The test pattern (figure 2) and the followingparagraphs shall represent a recommended im-plementation of the p
13、attern. Specific informationfor digital implementation is given in table 1.3.2 The middle gray background is used to iso-late the gray-scale and center resolution patternfrom interference by adjacent patterns.3.3 Crosshatch lines in the horizontal directionshall be two raster lines wide, and in the
14、verticaldirection, lines shall be of a width equal to tworaster lines. The intensity of the line shall be75% of the maximum signal. The patterns shownconsist of square spaces equal to 10% of theraster height. Rectangular aspect ratios and dif-ferent numbers of scan lines may require frac-tional spac
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SMPTERP1331991SPECIFICATIONSFORMEDICALDIAGNOSTICIMAGINGTESTPATTERNFORTELEVISIONMONITORSANDHARDCOPYRECORDINGCAMERAS

链接地址:http://www.mydoc123.com/p-1046370.html