SANS 6169-2010 Water - Aluminium content《水 铝含量》.pdf
《SANS 6169-2010 Water - Aluminium content《水 铝含量》.pdf》由会员分享,可在线阅读,更多相关《SANS 6169-2010 Water - Aluminium content《水 铝含量》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-24444-6 SANS 6169:2010Edition 1.2SOUTH AFRICAN NATIONAL STANDARD Water Aluminium content Published by SABS Standards Division 1 Dr Lategan
4、 Road Groenkloof Private Bag X191 Pretoria 0001Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS SANS 6169:2010 Edition 1.2 Table of changes Change No. Date Scope Amdt 1 2005 Amended to change the designation of SABS standards to SANS standards and to update referenced standards. Amdt 2
5、2010 Amended to update referenced standards. Foreword This South African standard was approved by National Committee SABS SC 147A, Water Water sampling and analysis, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This document was p
6、ublished in April 2010. This document supersedes SANS 6169:2005 (edition 1.1). A vertical line in the margin shows where the text has been technically modified by amendment No. 2. SANS 6169:2010 Edition 1.2 1 Water Aluminium content 1 Scope and field of application This standard specifies a method o
7、f determining the aluminium content of water and wastewater, using a nitrous oxide-acetylene flame and direct flame atomic absorption. The method is applicable to the determination of aluminium in the concentration range 0,1 mg/L to 100 mg/L. 2 Normative references The following referenced documents
8、 are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. Information on currently valid national and international standards can be obtained
9、 from the SABS Standards Division. Amdt 1 SANS 111/ISO 835, Laboratory glassware Graduated pipettes. Amdt 1; amdt 2 SANS 112/ISO 648, Laboratory glassware Single volume pipettes. Amdt 1 SANS 115/ISO 385, Laboratory glassware Burettes. Amdt 1; amdt 2 SANS 128/ISO 1042, Laboratory glassware One-mark v
10、olumetric flasks. Amdt 1 SANS 3696/ISO 3696, Water for analytical laboratory use Specification and test methods. SANS 6168, Water Pretreatment for metal analysis. 3 Principle The pretreated sample is aspirated into a nitrous oxide-acetylene flame, using potassium as an ionization suppressor. The abs
11、orbance measured at 309,3 nm is compared with the absorbance of aluminium standards measured under the same conditions. 4 Reagents NOTE Unless otherwise specified, only use water that complies with the requirements of SANS 3696 and reagents of analytical reagent grade. 4.1 Nitric acid (HNO3) Concent
12、rated (d at 25 /25 C = 1,42). SANS 6169:2010 Edition 1.2 2 4.2 Acidified water Containing 1,5 mL of HNO3(see 4.1) per litre. 4.3 Aluminium stock solution (1 000 mg/L) 4.3.1 Obtain a commercially available stock solution of aluminium (1 000 mg/L) of guaranteed quality, or prepare the stock solution a
13、s described in 4.3.2. 4.3.2 Dissolve 17,584 g of aluminium potassium sulfate (AlK(SO4)212H2O), previously dried in a desiccator for 24 h, in 200 mL of water. Add 1,5 mL of HNO3(see 4.1) and dilute with water to 1 000 mL in a volumetric flask. 4.4 Aluminium working stock solution (100 mg/L) Pipette 1
14、0,0 mL of the stock solution (see 4.3) into a 100 mL volumetric flask and dilute to the mark with acidified water (see 4.2). 4.5 Aluminium standard solutions (0,1 mg/L to 100 mg/L) 4.5.1 Prepare at least three aluminium standard solutions that will bracket the expected concentration of the sample by
15、 dilution of the working stock solution (see 4.4), using the acidified water (see 4.2) as the diluent. 4.5.2 Add 2,0 mL of the KCl solution (see 4.6) to 100 mL of each of the standards. 4.6 Potassium chloride (KCl) solution (250 g/L) Dissolve 250 g of KCl in water and dilute to 1 000 mL in a volumet
16、ric flask. 5 Apparatus 5.1 Atomic absorption spectrophotometer For use at 309,3 nm. 5.2 Nitrous oxide burner Suitable for attachment to the spectrophotometer (see 5.1). 5.3 Aluminium hollow-cathode lamp 5.4 Oxidant 5.4.1 Air, dried and filtered to support combustion before switching to nitrous oxide
17、. 5.4.2 Nitrous oxide, commercially bottled gas. 5.5 Fuel Acetylene, standard commercial grade. (Replace the cylinder when the cylinder pressure drops to 700 kPa.) SANS 6169:2010 Edition 1.2 3 CAUTION: Never allow the operating pressure of acetylene to exceed 105 kPa. 5.6 Pressure-reducing regulator
18、s For the supply of fuel and oxidant to the instrument at the appropriate levels recommended by the manufacturer. 5.7 Glassware Where applicable, only use burettes, pipettes and volumetric flasks that comply with the requirements for class A items as specified in SANS 111, SANS 112, SANS 115 and SAN
19、S 128, as relevant. Amdt 1; amdt 2 6 Sample pretreatment 6.1 Pretreat the sample, a blank (see 4.2) and at least one standard (see 4.5.1) in accordance with SANS 6168 in order to analyse for the appropriate form of metal, i.e. soluble, insoluble or total metal. NOTE For the purposes of legislation o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS61692010WATERALUMINIUMCONTENT 含量 PDF
链接地址:http://www.mydoc123.com/p-1031640.html