SANS 61094-2-2009 Electroacoustics - Measurement microphones Part 2 Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique《电声学 麦克风测.pdf
《SANS 61094-2-2009 Electroacoustics - Measurement microphones Part 2 Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique《电声学 麦克风测.pdf》由会员分享,可在线阅读,更多相关《SANS 61094-2-2009 Electroacoustics - Measurement microphones Part 2 Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique《电声学 麦克风测.pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-22292-5 SANS 61094-2:2009Edition 1IEC 61094-2:2009Edition 2SOUTH AFRICAN NATIONAL STANDARD Electroacoustics Measurement microphones Part 2
4、: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique This national standard is the identical implementation of IEC 61094-2:2009 and is adopted with the permission of the International Electrotechnical Commission. Published by SABS Standards Divisi
5、on 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS SANS 61094-2:2009 Edition 1 IEC 61094-2:2009 Edition 2 Table of changes Change No. Date Scope National foreword This South African standard was approved by National Committee S
6、ABS TC 76, Acoustics, electro-acoustics and vibration, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This SANS document was published in July 2009. IEC 61094-2Edition 2.0 2009-02INTERNATIONAL STANDARD NORME INTERNATIONALEElectroaco
7、ustics Measurement microphones Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique Electroacoustique Microphones de mesure Partie 2: Mthode primaire pour ltalonnage en pression des microphones talons de laboratoire par la mthode de rciproci
8、t INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE XICS 17.140.50 PRICE CODECODE PRIXISBN 2-8318-1030-4 Registered trademark of the International Electrotechnical Commission Marque dpose de la Commission Electrotechnique Internationale SANS 61094-2:2009This s tand
9、ard may only be used and printed by approved subscription and freemailing clients of the SABS . 2 61094-2 IEC:2009 CONTENTS FOREWORD.4 1 Scope.6 2 Normative references .6 3 Terms and definitions .6 4 Reference environmental conditions .7 5 Principles of pressure calibration by reciprocity 7 5.1 Gene
10、ral principles .7 5.1.1 General .7 5.1.2 General principles using three microphones 7 5.1.3 General principles using two microphones and an auxiliary sound source .7 5.2 Basic expressions .8 5.3 Insert voltage technique 9 5.4 Evaluation of the acoustic transfer impedance.9 5.5 Heat-conduction correc
11、tion11 5.6 Capillary tube correction11 5.7 Final expressions for the pressure sensitivity 12 5.7.1 Method using three microphones .12 5.7.2 Method using two microphones and an auxiliary sound source 12 6 Factors influencing the pressure sensitivity of microphones13 6.1 General .13 6.2 Polarizing vol
12、tage13 6.3 Ground-shield reference configuration.13 6.4 Pressure distribution over the diaphragm 13 6.5 Dependence on environmental conditions .14 6.5.1 Static pressure 14 6.5.2 Temperature14 6.5.3 Humidity 14 6.5.4 Transformation to reference environmental conditions .15 7 Calibration uncertainty c
13、omponents15 7.1 General .15 7.2 Electrical transfer impedance 15 7.3 Acoustic transfer impedance .15 7.3.1 General .15 7.3.2 Coupler properties.15 7.3.3 Microphone parameters .16 7.4 Imperfection of theory17 7.5 Uncertainty on pressure sensitivity level18 Annex A (normative) Heat conduction and visc
14、ous losses in a closed cavity 20 Annex B (normative) Acoustic impedance of a capillary tube23 Annex C (informative) Examples of cylindrical couplers for calibration of microphones 26 Annex D (informative) Environmental influence on the sensitivity of microphones 31 Annex E (informative) Methods for
15、determining microphone parameters 34 Annex F (informative) Physical properties of humid air.37 SANS 61094-2:2009This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .61094-2 IEC:2009 3 Figure 1 Equivalent circuit for evaluating the acoustic transfe
16、r impedance Za,12.9 Figure 2 Equivalent circuit for evaluating Za,12when coupler dimensions are small compared with wavelength10 Figure 3 Equivalent circuit for evaluating Za,12 when plane wave transmission in the coupler can be assumed .10 Figure C.1 Mechanical configuration of plane-wave couplers
17、.27 Figure C.2 Mechanical configuration of large-volume couplers.29 Figure D.1 Examples of static pressure coefficient of LS1P and LS2P microphones relative to the low-frequency value as a function of relative frequency f/fo32 Figure D.2 General frequency dependence of that part of the temperature c
18、oefficient for LS1P and LS2P microphones caused by the variation in the impedance of the enclosed air 33 Table 1 Uncertainty components19 Table A.1 Values for EV.21 Table B.1 Real part of Za,Cin gigapascal-seconds per cubic metre (GPas/m3)24 Table B.2 Imaginary part of Za,Cin gigapascal-seconds per
19、cubic metre (GPas/m3)25 Table C.1 Nominal dimensions for plane-wave couplers.28 Table C.2 Nominal dimensions and tolerances for large-volume couplers 29 Table C.3 Experimentally determined wave-motion corrections for the air-filled large-volume coupler used with type LS1P microphones30 Table F.1 Cal
20、culated values of the quantities in Clauses F.1 to F.5 for two sets of environmental conditions 40 Table F.2 Coefficients used in the equations for humid air properties.41 SANS 61094-2:2009This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS . 4 61
21、094-2 IEC:2009 INTERNATIONAL ELECTROTECHNICAL COMMISSION _ ELECTROACOUSTICS MEASUREMENT MICROPHONES Part 2: Primary method for pressure calibration of laboratory standard microphones by the reciprocity technique FOREWORD 1) The International Electrotechnical Commission (IEC) is a worldwide organizat
22、ion for standardization comprising all national electrotechnical committees (IEC National Committees). The object of IEC is to promote international co-operation on all questions concerning standardization in the electrical and electronic fields. To this end and in addition to other activities, IEC
23、publishes International Standards, Technical Specifications, Technical Reports, Publicly Available Specifications (PAS) and Guides (hereafter referred to as “IEC Publication(s)”). Their preparation is entrusted to technical committees; any IEC National Committee interested in the subject dealt with
24、may participate in this preparatory work. International, governmental and non-governmental organizations liaising with the IEC also participate in this preparation. IEC collaborates closely with the International Organization for Standardization (ISO) in accordance with conditions determined by agre
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS6109422009ELECTROACOUSTICSMEASUREMENTMICROPHONESPART2PRIMARYMETHODFORPRESSURECALIBRATIONOFLABORATORYSTANDARDMICROPHONESBYTHERECIPROCITYTECHNIQUE

链接地址:http://www.mydoc123.com/p-1031541.html