SANS 61089-1991 Round wire concentric lay overhead electrical stranded conductors《圆线同心绞高架导线》.pdf
《SANS 61089-1991 Round wire concentric lay overhead electrical stranded conductors《圆线同心绞高架导线》.pdf》由会员分享,可在线阅读,更多相关《SANS 61089-1991 Round wire concentric lay overhead electrical stranded conductors《圆线同心绞高架导线》.pdf(54页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-21071-7 SANS 61089:1991Edition 1 and IEC amdt 1, nat. amdt 1IEC 61089:1991Edition 1 and amdt 1 Any reference to SABS IEC 61089 is deemedto
4、 be a reference to this standard(Government Notice No. 1373 of 8 November 2002)SOUTH AFRICAN NATIONAL STANDARD Round wire concentric lay overhead electrical stranded conductors This national standard is the identical implementation of IEC 61089:1991 and IEC amendment 1, and is adopted with the permi
5、ssion of the International Electrotechnical Commission. Published by Standards South Africa 1 dr lategan road groenkloof private bag x191 pretoria 0001 tel: 012 428 7911 fax: 012 344 1568 international code + 27 12 www.stansa.co.za Standards South Africa SANS 61089:1991 Edition 1 and IEC amdt 1, nat
6、. amdt 1 IEC 61089:1991 Edition 1 and amdt 1 Table of changes Change No. Date Scope IEC amdt 1 1997 Amended to include aluminium-clad steel wires. Nat. amdt 1 2008 Amended to change the designation from SABS to SANS, with no technical changes. National foreword This South African standard was approv
7、ed by National Committee StanSA TC 66, Electric cables, in accordance with procedures of Standards South Africa, in compliance with annex 3 of the WTO/TBT agreement. This SANS document was published in June 2008. This SANS document supersedes SABS IEC 61089:1991 (first edition as modified by IEC amd
8、t 1:1997). NORMEINTERNATIONALECEIIECINTERNATIONALSTANDARD610891991AMENDEMENT 1AMENDMENT 11997-05Amendement 1Conducteurs pour lignes ariennes brins circulaires, cbls en couchesconcentriquesAmendment 1Round wire concentric lay overheadelectrical stranded conductorsHPour prix, voir catalogue en vigueur
9、For price, see current catalogueCODE PRIXPRICE CODE IEC 1997 Droits de reproduction rservs Copyright - all rights reservedInternational Electrotechnical Commission 3, rue de Varemb Geneva, SwitzerlandTelefax: +41 22 919 0300 e-mail: inmailiec.ch IEC web site http: /www.iec.chCommission Electrotechni
10、que InternationaleInternational Electrotechnical CommissionSANS 61089:1991This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .61089 Amend. 1 IEC:1997 3 FOREWORDThis amendment has been prepared by IEC technical committee 7: Overhead electricalcond
11、uctors.The text of this amendment is based on the following documents:FDIS Report on voting7/502/FDIS 7/506/RVDFull information on the voting for the approval of this amendment can be found in the report onvoting indicated in the above table.Page 71 ScopeAmend as follows:1.1 This International Stand
12、ard specifies the electrical and mechanical characteristics ofround wire, concentric lay, overhead, electrical and stranded conductors made of combinationsof any of the following metal wires:a) Aluminium wires hard drawn aluminium as per IEC 60889 designated A1*; aluminium alloy type B as per IEC 60
13、104, designated A2*; aluminium alloy type A as per IEC 60104, designated A3*.b) Zinc coated steel wires (as per IEC 60888): regular strength steel, designated S1A or S1B, where A and B are zinc coatingclasses, corresponding respectively to classes 1 and 2; high strength steel, designated S2A or S2B,
14、 extra high strength steel, designated S3A.c) Aluminium-clad steel wires (as per IEC 61232): class 20SA, types A and B, designated respectively SA1A and SA1B; class 27SA, designated as SA2.*The resistivity of these metals is as follows (in increasing order):A1: 28,264 nm (corresponding to 61 % IACS)
15、,A2: 32,530 nm (corresponding to 53 % IACS),A3: 32,840 nm (corresponding to 52,5 % IACS).SANS 61089:1991This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .61089 Amend. 1 IEC:1997 5 1.2 The conductor designations included in this standard are:A1,
16、 A2, A3,A1/S1A, A1/S1B, A1/S2A, A1/S2B, A1/S3A,A2/S1A, A2/S1B, A2/S3A,A3/S1A, A3/S1B, A3/S3A,A1/A2, A1/A3,A1/SA1A, A2/SA1A, A3/SA1A,S1A, S1B, S2A, S3A,SA1A, SA1B, SA2.NOTE Conductors made of the same wire designation are called homogeneous conductors (e.g. A1, A2, S1A,SA2, etc.). Furthermore, whenev
17、er reference is made to steel wires or conductors, these can either bealuminium-clad or zinc-coated (Sx or SAx).2 Normative referencesAdd, to the list, the title of the following standard:IEC 61232: 1993, Aluminium-clad steel wires for electrical purposesPage 93 Designation systemAdd the following p
18、aragraphs at the end of 3.2:Homogeneous conductors made of zinc-coated steel wires are designated S1A, S1B, S2A,S3A.Homogeneous conductors made of aluminium-clad steel wires are designated SA1A, SA1B orSA2.Add the following paragraph at the end of 3.4:When aluminium-clad steel wires SA1A are used in
19、 a composite conductor instead of zinc-coated wires, the designation becomes Ax/SA1A.Add the following paragraphs at the end of 3.5:500-A1/SA1A-54/7: Conductor made of 54 wires of A1 aluminium and 7 wires of aluminium-clad steel class 20SA wires, type A (SA1A). The area of the A1 aluminium wires is
20、equal to484 mm2and 62,8 mm2for the aluminium-clad steel wires which can be found in the tablesof annex D.40-SA1A-19: Conductor made of 19 wires of aluminium-clad steel wires class 20SA, type A(SA1A). The area of aluminium-clad steel wires is 120 mm2which has the same conductivityas 40 mm2 of A1 alum
21、inium wires.40-S1A-19: Conductor made of 19 wires of regular strength steel wires, with a zinc coatingtype A (S1A). The area of steel wires is 271,1 mm2which has the same conductivity as 40mm2of A1 aluminium wires.SANS 61089:1991This s tandard may only be used and printed by approved subscription an
22、d freemailing clients of the SABS .61089 Amend. 1 IEC:1997 7 4 DefinitionsAmend, on page 11, the definition of “steel ratio” as follows:steel ratio: The ratio of steel cross-sectional area to aluminium cross-sectional area given asa percentage.Page 115.1 MaterialAmend as follows:Conductors shall be
23、made up of round aluminium wires, or round steel wires (zinc-coated oraluminium-clad) or their combinations. All wires shall have before stranding the propertiesspecified in IEC 60104, IEC 60888, IEC 60889, and IEC 61232.Page 135.4 StrandingAmend 5.4.4 as follows:5.4.4 The lay ratios for steel wires
24、 (zinc-coated or aluminium-clad) shall be as follows:a) The lay ratio for the 6-wire layer of the 7 and 19-wire steel cores shall be not less than 16nor more than 26.b) The lay ratio for the 12-wire layer of 19-wire steel core shall be not less than 14 nor morethan 22.c) The lay ratio for homogeneou
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS610891991ROUNDWIRECONCENTRICLAYOVERHEADELECTRICALSTRANDEDCONDUCTORS 同心 绞高架 导线 PDF

链接地址:http://www.mydoc123.com/p-1031538.html