SANS 216-4-1-2009 Specification for radio disturbance and immunity measuring apparatus and methods Part 4-1 Uncertainties statistics and limit modelling - Uncertainties in standard.pdf
《SANS 216-4-1-2009 Specification for radio disturbance and immunity measuring apparatus and methods Part 4-1 Uncertainties statistics and limit modelling - Uncertainties in standard.pdf》由会员分享,可在线阅读,更多相关《SANS 216-4-1-2009 Specification for radio disturbance and immunity measuring apparatus and methods Part 4-1 Uncertainties statistics and limit modelling - Uncertainties in standard.pdf(122页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-22804-0 SANS 216-4-1:2009Edition 2CISPR/TR 16-4-1:2009Edition 2SOUTH AFRICAN NATIONAL STANDARD Specification for radio disturbance and imm
4、unity measuring apparatus and methods Part 4-1: Uncertainties, statistics and limit modelling Uncertainties in standardized EMC tests This national standard is the identical implementation of CISPR/TR 16-4-1:2009 and is adopted with the permission of the International Electrotechnical Commission (In
5、ternational Special Committee on Radio Interference). Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS SANS 216-4-1:2009 Edition 2 CISPR/TR 16-4-1:2009 Edition 2 Table of changes Change No. D
6、ate Scope National foreword This South African standard was approved by National Committee SABS TC 73, Electromagnetic compatibility, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This SANS document was published in September 2009.
7、 This SANS document supersedes SANS 216-4-1:2005 (edition 1.1 as modified by CISPR amdt 2:2007). CISPR/TR 16-4-1Edition 2.0 2009-02TECHNICAL REPORT Specification for radio disturbance and immunity measuring apparatus and methods Part 4-1: Uncertainties, statistics and limit modelling Uncertainties i
8、n standardized EMC tests INTERNATIONAL ELECTROTECHNICAL COMMISSION XEICS 33.100.10; 33.100.20 PRICE CODEISBN 2-8318-1032-4INTERNATIONAL SPECIAL COMMITTEE ON RADIO INTERFERENCE Registered trademark of the International Electrotechnical Commission SANS 216-4-1:2009This s tandard may only be used and p
9、rinted by approved subscription and freemailing clients of the SABS . 2 TR CISPR 16-4-1 IEC:2009(E) CONTENTS FOREWORD.7 INTRODUCTION.9 1 Scope.10 2 Normative references .10 3 Terms, definitions, and abbreviations .11 3.1 Terms and definitions 12 3.2 Abbreviations 15 4 Basic considerations on uncerta
10、inties in emission measurements.15 4.1 Introductory remarks .15 4.2 Types of uncertainties in emission measurements .17 4.2.1 General .17 4.2.2 Purpose of uncertainty considerations .18 4.2.3 Categories of uncertainty sources19 4.2.4 Summary of types of uncertainties.22 4.2.5 Influence quantities .2
11、2 4.2.6 The measurand and the intrinsic uncertainty23 4.3 Relation between standards compliance uncertainty and interference probability .25 4.3.1 General .25 4.3.2 The measurand and the associated limit25 4.3.3 Process of determination and application of uncertainties26 4.4 Assessment of uncertaint
12、ies in a standardised emission measurement .27 4.4.1 The process of uncertainty estimation27 4.4.2 Step 1: Definition of the purpose of the uncertainty consideration27 4.4.3 Step 2: Identifying the measurand, its uncertainty sources and influence quantities28 4.4.4 Step 3: Evaluate the standard unce
13、rtainty of each relevant influence quantity .29 4.4.5 Step 4: Calculation of the combined and expanded uncertainty .30 4.5 Verification of the uncertainty budget 31 4.5.1 Introductory remarks31 4.5.2 Test laboratory comparison and the measurement compatibility requirement .32 4.5.3 Interlaboratory c
14、omparison and statistical evaluation.34 4.5.4 Application of a calculable EUT .35 4.5.5 Application of a reference EUT 35 4.6 Reporting of the uncertainty 35 4.6.1 General .35 4.6.2 Reporting results of uncertainty assessments36 4.6.3 Uncertainty statements in routine compliance measurement results.
15、36 4.6.4 Reporting of the expanded uncertainty 36 4.7 Application of uncertainties in the compliance criterion37 4.7.1 Introductory remarks37 4.7.2 Manufacturers compliance criterion for compliance measurements .41 4.7.3 Compliance criteria for mass-produced products (80 %/80 % rule) 41 4.7.4 Compli
16、ance criteria for quality assurance tests using a reference EUT42 4.7.5 Application of uncertainties in re-testing 42 SANS 216-4-1:2009This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS .TR CISPR 16-4-1 IEC:2009(E) 3 5 Basic considerations on unc
17、ertainties in immunity testing.44 6 Voltage measurements.44 6.1 Introductory remarks .44 6.2 Voltage measurements (general).44 6.2.1 Introductory remarks44 6.2.2 Voltage measurements basics .44 6.2.3 The disturbance source and types of voltage .46 6.3 Voltage measurements using a voltage probe .48 6
18、.4 Voltage measurement using a V-terminal artificial mains network48 6.4.1 Introductory remarks48 6.4.2 Basic circuit diagram of the voltage measurement .49 6.4.3 Voltage measurement and standards compliance uncertainty 50 6.4.4 Combined uncertainty51 6.4.5 The compliance criterion52 6.4.6 Influence
19、 quantities .52 7 Absorbing clamp measurements.56 7.1 General .56 7.1.1 Objective .56 7.1.2 Introductory remarks57 7.2 Uncertainties related to the calibration of the absorbing clamp 57 7.2.1 General .57 7.2.2 The measurand .58 7.2.3 Uncertainty sources.58 7.2.4 Influence quantities .59 7.2.5 Applic
20、ation of the uncertainty budget .63 7.2.6 Typical examples of an uncertainty budget 63 7.2.7 Verification of the uncertainty budget.64 7.3 Uncertainties related to the absorbing clamp measurement method 64 7.3.1 General .64 7.3.2 The measurand .64 7.3.3 Uncertainty sources.65 7.3.4 Influence quantit
21、ies .66 7.3.5 Application of the uncertainty budget .68 7.3.6 Typical examples of the uncertainty budget .68 7.3.7 Verification of the uncertainty budget.69 8 Radiated emission measurements using a SAC or an OATS in the frequency range of 30 MHz to 1 000 MHz .71 8.1 General .71 8.1.1 Objective .71 8
22、.1.2 Introductory remarks71 8.2 Uncertainties related to the SAC/OATS radiated emission measurement method72 8.2.1 General .72 8.2.2 The measurand .73 8.2.3 Uncertainty sources.74 8.2.4 Influence quantities .75 8.2.5 Application of the uncertainty estimate 86 8.2.6 Typical examples of the uncertaint
23、y estimate.86 SANS 216-4-1:2009This s tandard may only be used and printed by approved subscription and freemailing clients of the SABS . 4 TR CISPR 16-4-1 IEC:2009(E) 8.2.7 Verification of the uncertainty estimate 87 9 Conducted immunity measurements .88 10 Radiated immunity measurements 88 Annex A
24、 (informative) Compliance uncertainty and interference probability89 Annex B (informative) Numerical example of the consequences of Faradays law 91 Annex C (informative) Possible amendments to CISPR publications with regards to voltage measurements .93 Annex D (informative) Analysis method of result
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS216412009SPECIFICATIONFORRADIODISTURBANCEANDIMMUNITYMEASURINGAPPARATUSANDMETHODSPART41UNCERTAINTIESSTATISTICSANDLIMITMODELLINGUNCERTAINTIESINSTANDARDPDF

链接地址:http://www.mydoc123.com/p-1030096.html