SANS 10198-11-2010 The selection handling and installation of electric power cables of rating not exceeding 33 kV Part 11 Jointing and termination of screened polymeric-insulated c.pdf
《SANS 10198-11-2010 The selection handling and installation of electric power cables of rating not exceeding 33 kV Part 11 Jointing and termination of screened polymeric-insulated c.pdf》由会员分享,可在线阅读,更多相关《SANS 10198-11-2010 The selection handling and installation of electric power cables of rating not exceeding 33 kV Part 11 Jointing and termination of screened polymeric-insulated c.pdf(40页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. ISBN 978-0-626-23287-0 SANS 10198-11:2010Edition 2 SOUTH AFRICAN NATIONAL STANDARD The selection, handling and installation of electric power cables of r
4、ating not exceeding 33 kV Part 11: Jointing and termination of screened polymeric-insulated cables Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001Tel: +27 12 428 7911 Fax: +27 12 344 1568 www.sabs.co.za SABS SANS 10198-11:2010 Edition 2 Table of chang
5、es Change No. Date Scope Foreword This South African standard was approved by National Committee SABS TC 66, Electric cables, in accordance with procedures of the SABS Standards Division, in compliance with annex 3 of the WTO/TBT agreement. This document was published in January 2010. This document
6、supersedes SABS 0198-11:1988 (edition 1 as modified by amdt 1:1990). SANS 10198 consists of the following parts, under the general title The selection, handling and installation of electric power cables of rating not exceeding 33 kV: Part 1: Definitions and statutory requirements. Part 2: Selection
7、of cable type and methods of installation. Part 3: Earthing systems General provisions. Part 4: Current ratings. Part 5: Determination of thermal and electrical resistivity of soil. Part 6: Transportation and storage. Part 7: Safety precautions. Part 8: Cable laying and installation. Part 9: Jointin
8、g and termination of extruded solid dielectric-insulated cables up to 3,3 kV. Part 10: Jointing and termination of paper-insulated cables. Part 11: Jointing and termination of screened polymeric-insulated cables. Part 12: Installation of earthing system. Part 13: Testing, commissioning and fault loc
9、ation. Part 14: Installation of aerial bundled conductor (ABC) cables. NOTE The first five parts deal with factors to be taken into account when an electrical distribution system is being designed. The last nine parts deal with the practical aspects of handling and installing cables. Annexes A to C
10、are for information only. SANS 10198-11:2010 Edition 2 1 Introduction This part of SANS 10198 incorporates the techniques used for the jointing and termination of screened polymeric insulated cables using dry-type accessories including heat-shrink, cold-shrink and other cold-applied technologies. Th
11、e methods described in this part of SANS 10198 cover medium voltage multi-core cables but the same principles apply to single-core cables. The construction of screened polymeric insulated cables referred to in this standard is based upon the requirements of SANS 1339. SANS 10198-11:2010 Edition 2 2
12、This page is intentionally left blank SANS 10198-11:2010 Edition 2 3 Contents Page Foreword Introduction 1 Scope . 5 2 Normative references 5 3 Definitions and abbreviations 6 4 Common procedures for cable jointers. 7 4.1 Preliminaries . 7 4.2 Safety 7 4.3 Moisture test (crackle test) on the impregn
13、ated paper-insulated cable side of transition joints. 8 4.4 Common jointing practices . 8 4.5 Stress control in joints and terminations to prevent partial discharge 9 4.6 Voids . 11 4.7 Moisture 11 5 Jointing 11 5.1 Preparation . 12 5.2 Cable preparation . 13 5.3 Connecting of conductors. 16 5.4 Fer
14、rule stress control 17 5.5 Dry-type joints: heat-shrink. 17 5.6 Dry-type joints: cold-shrink . 19 5.7 Transition jointing systems . 20 6 Termination . 206.1 General . 20 6.2 Preparation . 21 6.3 Cable preparation . 22 6.4 Fitting of lugs. 26 6.5 Termination tail outer tubes and the sealing of the in
15、terface between the outer tube and the lug barrel 27 6.6 Types of terminations used in air-filled enclosures. 28 6.7 Outdoor terminations 31 SANS 10198-11:2010 Edition 2 4 Contents (concluded) Page Annex A (Informative) Jointers tool kit. 32 Annex B (Informative) Earth-fault path in single-core cabl
16、e systems 33 Annex C (Informative) Types of terminations in air-filled enclosures. 34 Bibliography. 36 SANS 10198-11:2010 Edition 2 5 The selection, handling and installation of electric power cables of rating not exceeding 33 kV Part 11: Jointing and termination of screened polymeric-insulated cabl
17、es 1 Scope 1.1 This part of SANS 10198 covers: a) the jointing and termination of medium-voltage screened polymeric cables; and b) the transition jointing of impregnated paper-insulated to screened polymeric (e.g. XLPE) insulated cables. This part of SANS 10198 excludes installation in hazardous are
18、as and undergroud mines. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced documents (including any amendments) applies.
19、Information on currently valid national and international standards can be obtained from the SABS Standards Division. SANS 876, Cable terminations and live conductors within air-filled enclosures (insulation co-ordination) for rated a.c. voltages from 7,2 kV up to and including 36 kV. SANS 6281-4, T
20、est methods for impregnated paper-insulated electric cables Part 4: Tests after installation. SANS 10198-1, The selection, handling and installation of electric power cables of rating not exceeding 33 kV Part 1: Definitions and statutory requirements. SANS 10198-7, The selection, handling and instal
21、lation of electric power cables of rating not exceeding 33 kV Part 7: Safety precautions. SANS 10198-10, The selection, handling and installation of electric power cables of rating not exceeding 33 kV Part 10: Jointing and termination of paper-insulated cables. SANS 10198-11:2010 Edition 2 6 3 Defin
22、itions and abbreviations 3.1 For the purposes of this document, the definitions in SANS 10198-1, and the following apply: 3.1.1 air-filled enclosure metallic enclosure designed to protect the ends of cables, bushings, current transformers or live conductors 3.1.2 air-insulated termination (type 1 te
23、rmination) air-filled enclosure within which the cable cores are electrically terminated by stress control appropriate to the cable design and voltage with air being the sole insulation for the terminal connections 3.1.3 cable jointer person skilled in the craft of jointing and terminating electric
24、cables 3.1.4 constant force spring CFS roll spring used to ensure continuous electrical and mechanical contact between an earthing conductor and the underlying metallic screen, metallic sheath or armour 3.1.5 jointing technique of applying a joint or termination on a cable 3.1.6 reference point refe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS10198112010THESELECTIONHANDLINGANDINSTALLATIONOFELECTRICPOWERCABLESOFRATINGNOTEXCEEDING33KVPART11JOINTINGANDTERMINATIONOFSCREENEDPOLYMERICINSULATEDCPDF

链接地址:http://www.mydoc123.com/p-1028679.html