SANS 10120-3 DK-1996 Code of practice for use with standardized specifications for civil engineering construction and contract documents Part 3 Guidance for design Section DK Gabio.pdf
《SANS 10120-3 DK-1996 Code of practice for use with standardized specifications for civil engineering construction and contract documents Part 3 Guidance for design Section DK Gabio.pdf》由会员分享,可在线阅读,更多相关《SANS 10120-3 DK-1996 Code of practice for use with standardized specifications for civil engineering construction and contract documents Part 3 Guidance for design Section DK Gabio.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、 Collection of SANS standards in electronic format (PDF) 1. Copyright This standard is available to staff members of companies that have subscribed to the complete collection of SANS standards in accordance with a formal copyright agreement. This document may reside on a CENTRAL FILE SERVER or INTRA
2、NET SYSTEM only. Unless specific permission has been granted, this document MAY NOT be sent or given to staff members from other companies or organizations. Doing so would constitute a VIOLATION of SABS copyright rules. 2. Indemnity The South African Bureau of Standards accepts no liability for any
3、damage whatsoever than may result from the use of this material or the information contain therein, irrespective of the cause and quantum thereof. SABS 01 20-3 Section DK:1996 Gabions and pitching First revision Part 3 : Guidance for design Section DK Contents Page l Pre-tenderconsiderations 1 1.1 I
4、nvestigations 1 1 . 1 . 1 Need for geotextiles and geomembranes . 1 1.2 Administration l 1.2.1 Provision for alternativelextra work . 1 1.3 Documentation . l 1 . 3.1 Project specification clauses 1 1.3.2 Pitching . 1 1.3.3 Foundations for gabion walls and aprons . l 1.3.4 Founding conditions for pit
5、ching . 1 1.3.5 Scheduling 1 1.3.6 Tolerances 1 2 Designconsiderations 2 2.1 PVCcoating . 2 . 2.1.1 Where PVC coating should not be used 2 2.1.2 Where PVC coating has proved useful 2 2.1.3 Where the use of PVC coating should be considered 2 2.2 Maintenance and corrosion considerations in design 2 2.
6、3 Wiremeshforgabions 2 . 2.4 Firmness of lacing 2 2.5 Gabionmattresses . 3 2.6 Useofgeotextiles . 3 2.7 Examplesofdesign 3 2.7.1 Bridgeabutments . 3 2.7.2 Mountainside stabilization 4 2.8 Gabiontolerances . 4 3 Applicability of other codes . 4 . 4 Testprocedures 4 5 Quality control and other conside
7、rations . 4 Drawings DK.3.1 Examples of gabion structures . 5 First revision 24 June 1996 This section of the code supersedes SABS 0120-3 : Section DK:1984 Approved by the PRESIDENT OF THE SOUTH AFRICAN BUREAU OF STANDARDS CODE OF PRACTICE SABS 0120-3 : Section DK:1996 SABS 1200 DK : Gabions and pit
8、ching NOTE - The clause number) given in brackets at the beginning or after the heading of a clause islare, unless otherwise stated, the number(s) of the relevant clause(s) of SABS 1200 DK. 1 Pre-tender considerations 1 .l lnvestigations 1 .l .l Need for geotextiles and geomembranes In the case of g
9、abions, establish the need or otherwise for geotextiles or geomembranes by investigating foundation conditions before completing the documentation for the project. Investigate substrata and other conditions on the site of the proposed gabion construction sufficiently thoroughly to ensure the disclos
10、ure of a seasonal water table and of seepage or other water that might adversely affect the proposed gabion construction and its foundations. (See also 2.6 below.) 1.2 Administration 1.2.1 Provision for alternativelextra work Ensure that provision is made in the schedule for prices to be tendered fo
11、r alternative or extra work that might be ordered while the works are being constructed. (See 1.3.4 and 1.3.5 below for examples of such items.) 1.3 Documentation 1.3.1 Project specification clauses 1.3.1 .l General Ensure that the project specification includes requirements arising from such design
12、 decisions as might be made in the light of 2.1 to 2.5 below and to cover the applicable of the matters set out in section DK of SABS 0120-2. 1.3.1.2 Tests on firmness of lacing (5.1.2) Where the design requirements are such that the firmness of the lacing must be greater than that specified in 5.1.
13、2 of SABS 1200 DK, include in the project specification requirements for the use of heavier binding wire and the achievement of a firmer attachment. (See also 2.4 below.) 1.3.2 Pitching (3.2) Ensure that clear directives are given as to whether pitching is to be extra heavy, heavy, medium or light.
14、1.3.3 Foundations for gabion walls and aprons (5.2.1) Ensure that details of the foundation trench to be constructed along the toe of the revetment(s) are given, and that the dimensions of such revetment(s) are clearly shown on the drawings. 1.3.4 Founding conditions for pitching (5.3.1) Ensure that
15、 the contract document includes details as to the extent to which a surface is to be compacted before construction of the pitching starts. Where so required, give details of backing. (See also 2.l(e) of section DK of SABS 01 20-2.) 1.3.5 Scheduling (8.2.1, 8.2.2, and 8.2.5 to 8.2.7) Ensure that: a)
16、an item is provided for filling cavities in the foundations with concrete, if use of concrete for this purpose is likely to be ordered; b) in the case of gabions, detail items are provided in the schedule for each size of box or mattress, each mesh size and each diaphragm spacing; c) in the case of
17、pitching, separate items are provided in the schedule for each type of pitching, and that suitable items are provided for additional excavation where it is likely that the toelfooting trench will have to be excavated to a depth exceeding 1 m vertically; d) the schedule provides for different thickne
18、sses of backing where more than one thickness of backing is likely to be required in terms of the project specification; and e) the schedule contains suitable items to cover weepholes. 1.3.6 Tolerances (6.1 ) See 2.8 below and 3.1.3(b) of section DK of SABS 0120-5. SABS 0120-3 Section DK:1996 Gabion
19、s and pitching First revision 2 Design considerations 2.5 PVC coating (3.1.2) 2.6.1 Where PVC coating should not be used PVC coating will not stand up to mechanical damage caused by heavy beach shingle being thrown against a wall by continuous wave acton, or by a mountain stream carrying a heavy loa
20、d of large sharp rocks. 2.1.2 Where PVC coating has proved useful PVC-coated mesh has been found to stand up to sand abrasion better than uncoated galvanized mesh and, in the case of gabions used in a jetty on a coastline that has a hot climate and where the sea water is warm, it has been found acce
21、ptably resistant to the effects of high ambient temperatures, long hours of sunlight and alternate wetting and drying. 2.1.3 Where the use of PVC coatlng should be considered In addition to its use in circumstances such as those described in 2.1.2 above, consider specifying PVC coating where a) the
22、resistivity of the soil is below 5 000 n.m, b) water that has a Langelier Index of -0,5 or lower is present, c) suifate-reducing bacteria are present, d) there is a constant flow of water at velocities exceeding 2 m/s, and e) milder abrasive action than that described in 2.1.1 above is present. 2.2
23、Maintenance and corrosion considerations in design The wire mesh used for gabions is required in terms of SABS 1200 DK to have a class A (heavy) zinc coating used for fencing and, where PVC coating is required, the thickness of the PVC is to be at least 0,50 mm because, when constructed, a) the hidd
24、en sides of the gabions will generally be in corrosive soils, and b) the cost of repairing or rectifying a structure that has collapsed or moved owing to failure of gabion cages will generally greatly exceed the initial installation cost and will always be far greater than the difference between the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SANS101203DK1996CODEOFPRACTICEFORUSEWITHSTANDARDIZEDSPECIFICATIONSFORCIVILENGINEERINGCONSTRUCTIONANDCONTRACTDOCUMENTSPART3GUIDANCEFORDESIGNSECTIONDKGABIOPDF

链接地址:http://www.mydoc123.com/p-1028518.html