SAE USCAR-34-2009 SPECIFICATION FOR TESTING AUTOMOTIVE LAMP ASSEMBLIES《试验性车灯装配规范》.pdf
《SAE USCAR-34-2009 SPECIFICATION FOR TESTING AUTOMOTIVE LAMP ASSEMBLIES《试验性车灯装配规范》.pdf》由会员分享,可在线阅读,更多相关《SAE USCAR-34-2009 SPECIFICATION FOR TESTING AUTOMOTIVE LAMP ASSEMBLIES《试验性车灯装配规范》.pdf(28页珍藏版)》请在麦多课文档分享上搜索。
1、 Specification for Testing Automotive Lamp Assemblies SAE/USCAR-34 October 2009 ISBN: 978-0-7680-3551-9 _ The research data, analysis, conclusion, opinions and other contents of this document are solely the product of the authors. Neither the SAE International (SAE) nor the United States Council for
2、 Automotive Research (USCAR) certifies the compliance of any products with the requirements of nor makes any representations as to the accuracy of the contents of this document nor to its applicability for purpose. It is the sole responsibility of the user of this document to determine whether or no
3、t it is applicable for their purposes. Copyright 2009 USCAR Printed in U.S.A. All rights reserved. QUESTIONS REGARDING THIS DOCUMENT: (248) 273-2470 FAX (248) 273-2494 TO PLACE A DOCUMENT ORDER: (724) 776-4970 FAX (724) 776-0790 SAE/USCAR-34 Issued 2009-10 SPECIFICATION FOR TESTING AUTOMOTIVE LAMP A
4、SSEMBLIES SUMMARY OF CONTENTS 1. SCOPE* 2 2. SAFETY PRECAUTIONS . 2 2.1 High Voltage Identification/Labeling . 2 3. REFERENCE STANDARDS . 3 4. DIAGRAMS AND DEFINITIONS 3 4.1 Appendices . 3 5. GENERAL REQUIREMENTS . 3 5.1 Record Retention 3 5.2 Sample Documentation and Retention . 4 5.3 Power Sources
5、 4 5.4 Equipment Tolerances 4 5.5 Measurement Accuracy 5 5.6 Test Repeatability and Calibration 5 5.7 Test Default Conditions . 5 5.8 Test Failure Procedure . 5 5.9 Control Plans . 5 5.10 Reliability Programs and Methods 5 5.11 Hazardous Material Restriction . 6 6. ENVIRONMENTAL TESTS 6 6.1 Internal
6、 Heat 6 6.2 Vibration with Temperature Cycling 7 6.3 Pressure Test (Lens Attachment Burst Test) 9 6.4 Pressure Test - Lamp In-Line Conformity . 10 6.5 Current Decay Light Up Test 11 6.6 Leakage Test (Dunk Test) 11 6.7 Resonant Frequencies 12 6.8 Fluid Compatibility . 12 6.9 Condensation 13 7. DURABI
7、LITY . 14 7.1 Salt Spray 14 7.2 30 Day Light-Up Test 15 7.3 Bi-Function High Beam Actuator Durability - Hot Ambient Temperature Transition Rates, Lamp Function Cycling. 5. Run vibration 10(L/A). 6.4 Pressure Test - Lamp In-Line Conformity This first half of this test is used to develop the minimum a
8、cceptance pressure value for the In-Line Conformity test. This test shall not be run on unsealed passenger compartment mounted lamps or sealed lamps that do not have designed openings. 6.4.1 Test and Measurement Apparatus Regulated Pressure source recommend orifice restrictor to limit air flow after
9、 failure occurs. Pressure Gage recommend gage that maintains max pressure attained for recording purposes. 6.4.2 Determining In-Line Pressure Test Value 1. Select 14 lamps of each unique part number representative of one shifts production. 2. Set lamps aside to allow lamp sealants to cure. 3. After
10、sealant is cured, install all lamp sockets and plug all vent holes except one. 4. Place lamp in enclosed chamber to protect test individuals. 5. Connect pressure source and gage to lamp using the unused vent hole. If the lamp does not have a vent hole, the socket opening may be used. 6. The lamp sha
11、ll not have any light sources illuminated during or 30 minutes prior to applying pressure. 7. Measure the total weld length (L) in inches. 8. Calculate the area (A) encased by the weld length in square inches. 9. Calculate the maximum test pressure (Pmax) in psi using the simplified formula Pmax=10(
12、L/A). 10. Increase pressure, starting at Pmin=2(L/A) in 20 equal steps, psi minimum step, to Pmax, dwelling for 10 seconds after each increment. 11. Stop test immediately if leak occurs or Pmaxis reached. 12. Turn off pressure. 13. Record pressure at the time leakage occurred. 14. Calculate and reco
13、rd the lower control limit to 3 sigma. 15. Inline conformity pressure shall be set to 80% of the 3 sigma lower control limit or 1 psi (6.9kPa), whichever is greater. 6.4.3 Determining Conformity Leak Rate Value 1. Select 30 lamps of the same part number representative of one shifts production. 2. Se
14、t lamps aside to allow lamp sealants to cure. 3. After sealant is cured, connect pressure source and gage to lamp. 4. The lamp shall not have any light sources illuminated during or 30 minutes prior to applying pressure. 5. Apply pressure defined in step 15 above to the lamp. 6. Turn off pressure. 7
15、. Monitor and record rate at which pressure decays in Standard cm3/min, over the same period as the 100% in-line conformity test. 8. Using the data recorded in step 7, calculate and record the upper control limit to 3 sigma. SAE/USCAR-34 Issued 2009-10 SPECIFICATION FOR TESTING AUTOMOTIVE LAMP ASSEM
16、BLIES - 11 - 6.4.4 Acceptance Criteria Pressure decay calculated in step 8 shall be used as the upper control limit for 100% In-line conformity testing. Pressure decay rate upper control limit used shall not exceed 35 Standard cm3/min. The lamp shall not have any light sources illuminated during 100
17、% In-line leak conformity testing. A known failure of the dunk test shall be put through this test to verify the integrity of this test and that a leak is detected If during production testing 6.5 Current Decay Light Up Test Current decay testing captures multiple values during the turn-on phase and
18、 compares the change, or rate of change, with expected norms. It can be a useful screening test to help find discrepant bulbs, “Leakers” that may be prone to early failures. This test is not to be run on Halogen bulbs. 6.5.1 Test and Measurement Apparatus Power Supply Current Measuring capability at
19、 each bulb function pin Strip Chart recorder 6.5.2 Procedure 1. Connect power, ground and signal functions to the lamp 2. Apply 12.8 Vdc to each non-halogen bulb function 3. Monitor current draw at each function using strip chart or equivalent recorder for 5 seconds +/-0.5 seconds 4. Take 4 measurem
20、ents after power is applied at 1.0 second, 1.5 seconds, 2.0 seconds and 3.0 seconds. 6.5.3 Acceptance Criteria Slope of decay shall be less than 20ma/sec averaged over the four readings 6.6 Leakage Test (Dunk Test) This is a water submersion test to visibly verify the lamp assembly does not leak. 6.
21、6.1 Test and Measurement Apparatus Water Tank filled with tap water Regulated Pressure source Pressure gage 6.6.2 Procedure 1. Install all mated vehicle connectors and install all lamp sockets, except one. Plug all vent holes. 2. Connect pressure source to lamp assembly through the one un-installed
22、lamp socket opening. 3. Increase pressure to 1 psi. (6.9 kPa) 4. Completely submerge lamp assembly in the water. 5. Move lamp under water to eliminate any trapped air due to lamp geometry. 6. Begin a 1 min inspection after exterior trapped bubbles are eliminated. 6.6.3 Acceptance Criteria There shal
23、l be no bubbles that emerge from the lamp while it is submerged. The lamp shall not allow water intrusion. SAE/USCAR-34 Issued 2009-10 SPECIFICATION FOR TESTING AUTOMOTIVE LAMP ASSEMBLIES - 12 - 6.7 Resonant Frequencies Resonant Frequency IEC 60068-2-64 Vibration, broad band random and guidance 6.7.
24、1 Measurement Apparatus Resonant Frequency Equipment Table Equipment Requirements Closed loop dynamic vibration equipment and auxiliary controller capable of vibrating in sinusoidal mode Variable from 10 - 2000 Hz with tolerance of 4.0 dB and min. of 5Gs Accelerometer one rigidly mounted to the fixt
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEUSCAR342009SPECIFICATIONFORTESTINGAUTOMOTIVELAMPASSEMBLIES 试验性 车灯 装配 规范 PDF

链接地址:http://www.mydoc123.com/p-1028401.html