SAE USCAR-21-2014 PERFORMANCE SPECIFICATION FOR CABLE-TO-TERMINAL ELECTRICAL CRIMPS (Revision 3).pdf
《SAE USCAR-21-2014 PERFORMANCE SPECIFICATION FOR CABLE-TO-TERMINAL ELECTRICAL CRIMPS (Revision 3).pdf》由会员分享,可在线阅读,更多相关《SAE USCAR-21-2014 PERFORMANCE SPECIFICATION FOR CABLE-TO-TERMINAL ELECTRICAL CRIMPS (Revision 3).pdf(44页珍藏版)》请在麦多课文档分享上搜索。
1、_The research data, analysis, conclusion, opinions and other contents of this document are solely the product of the authors. Neither the SAE International (SAE) nor the United States Council for Automotive Research (USCAR) certifies the compliance of any products with the requirements of nor makes
2、any representations as to the accuracy of the contents of this document nor to its applicability for purpose. It is the sole responsibility of the user of this document to determine whether or not it is applicable for theirpurposes.Copyright 2014 USCAR Printed in U.S.A.All rights reserved.QUESTIONS
3、REGARDING THIS DOCUMENT: (248) 273-2470 FAX (248) 273-2494TO PLACE A DOCUMENT ORDER: (724) 776-4970 FAX (724) 776-0790TABLE OF CONTENTS1. SCOPE 21.1 Crimping Parameters 22. DOCUMENTS . 32.1 Document Hierarchy . 32.2 Test Request/Order. 32.3 Materials and Process Specifications . 32.4 Referenced Docu
4、ments 33. GENERAL REQUIREMENTS. 43.1 Record Retention 43.2 Sample Documentation. 43.3 Sample Size 43.4 Default Test Tolerances 43.5 Test Default Conditions. 43.6 Equipment . 43.7 Definitions and Glossary . 53.8 Measurement Resolution 53.9 Test Repeatability items of customary laboratory equipment an
5、d supplies will also be required. Use of equipment with a lesser range is acceptable for specific tests where the required range for that test can be met. The equipment range specified does not preclude use of equipment with a larger range, but the accuracy must remain within the specified tolerance
6、.SAE/USCAR-21 REVISION 3 Revised 2014-11PERFORMANCE SPECIFICATION FOR CABLE-TO-TERMINAL ELECTRICAL CRIMPS - 5 -TABLE 3.6 - EQUIPMENT LISTDESCRIPTION REQUIREMENTSDC Power Supply (Regulated) 020V current sized as requiredMicro-Ohmmeter 0-20 mV maximum open circuit voltage100 mA maximum test current0.0
7、1 m: resolutionDigital Multimeter(DMM)Capable of measuring 0.001-50 Volts DC with accuracy of 0.5% of measurementMillivolt Meter Capable of measuring 0-100 mV DC with accuracy of 0.5 mV Thermocouples Type “J“ or “T“ as required (small size .08mm)Force Tester Capable of an accuracy of 1% of measureme
8、ntTemperature Cycling Chamber -40 C to 125 C, 0% to 98% RHThermal Shock Chamber -40 3 to 125 C (in 5 minutes or less)Forced Air Oven +85 3 CTemperature Chamber -40 3 CTemp. /Humidity Chamber 95 to 98% RH at +65 3 C3.7 Definitions and GlossaryDefinitions for technical terms are listed in Appendix B.
9、Abbreviations and acronyms are listed in Appendix C.3.8 Measurement ResolutionUnless otherwise specified, meters and gages used in measurements of test samples shall be capable of measuring with a resolution one decimal place better than the specified value. For example, wire diameter specified as 0
10、.1 mm might actually be the same as one specified as 0.10 mm, calipers capable of 0.01 mm resolution may be used to measure the first wire but a micrometer with 0.001 mm resolution is required to measure the second wire.3.9 Test Repeatability no strands outside the crimp or broken-off before the cri
11、mp are allowed. For wires 0.8mm stock. (For accurate crimp height measurement, it is recommended that the burr height not exceed the lowest position of the crimp.) The burr must not cause damage to any subsequent operation. Special care must be taken when using mat seals that can be cut by a burr. S
12、eals are validated per USCAR-2 for each connector design.FIGURE 4.3.5-2 - CONDUCTOR CRIMP BURR DETAIL3. Insulation cross-section (with no cable seal) must meet ideal views shown in Figure 4.3.5-3a or acceptable views in Figure 4.3.5.3b. No unacceptable cross-section views as shown in Figure 4.3.5-4c
13、 are allowed. For acceptance criteria on non-standard insulation crimp designs, refer to the terminal manufacturers recommendations; some insulation crimps serve as a functional part of the terminal/cavity retention system and functional failures will result from non-compliance. FIGURE 4.3.5-3A - ID
14、EAL INSULATION CRIMP CROSS-SECTIONS FOR DIFFERENT STYLE DESIGNSFIGURE 4.3.5-3B - ACCEPTABLE BUT NOT IDEAL INSULATION CRIMPSInsulation extruded outward between open insulation wingsIDEAL INSULATION CRIMPS HAVE:Symmetric crimpNo insulation penetrationWings embracing insulation Less than3-point contact
15、Insulation wings contact conductor (no damage allowed)0.1 mm max.LOWEST POINT OF CRIMP(USED FOR CCH MEASUREMENT)SAE/USCAR-21 REVISION 3 Revised 2014-11PERFORMANCE SPECIFICATION FOR CABLE-TO-TERMINAL ELECTRICAL CRIMPS - 13 -Insulation is splitFIGURE 4.3.5-3C - UNACCEPTABLE INSULATION CRIMPS4. Cable s
16、eals must have no nicks or cuts in the sealing ribs. Minimal nicks or cuts are allowed in the seal neck if functional seal retention requirements are met. Insulation crimp wings are not permitted to penetrate into the seal neck. See Figure 4.3.5-4a for a cross-sectional illustration of a cable seal
17、and Figure 4.3.5-4b for a mat seal. FIGURE 4.3.5-4A - CABLE SEAL CROSS-SECTION (INCLUDING TERMINAL AND WIRE)5. Crimped terminal and wire must be designed to avoid damage (such as nicks and cuts) to the sealing ribs when inserting terminated leads through mat seals. Refer to Figure 4.3.5-4b for a sam
18、ple cross-section view. Functional sealing performance is determined in USCAR-2 testing.FIGURE 4.3.5-4B - MAT SEAL APPLICATIONOne or both wings penetrate strandsOne or both wings penetrate throughSealing RibMat SealPlugged WireSAE/USCAR-21 REVISION 3 Revised 2014-11PERFORMANCE SPECIFICATION FOR CABL
19、E-TO-TERMINAL ELECTRICAL CRIMPS - 14 -4.4 Conductor Crimp Pull-Out Force Test4.4.1 PurposeThis procedure details a method to measure the retention capability of crimped connections. The pull-out force test is not be used to determine overall performance of the crimp application. It is intended to be
20、 used for mechanical crimp evaluation only. It will only be used to determine the mechanical limits of the application for handling purposes. Applications may require additional protection to assure the crimped circuit survives the harness handling and vehicle assembly process. 4.4.2 Equipment1. Mea
21、suring device capable of measuring crimp heights and widths2. De-crimping tool or other suitable means of opening insulation crimp wings without damaging the cable conductor (Note: It is acceptable to make the samples with the insulation wings not crimped to avoid this step.)3. Force tester4. Cable
22、strippers, long-nose pliers and/or side cutters 4.4.3 Samples1. A minimum of 20 samples is required to be tested for each tested crimp height (3 crimp heights minimum, 5 are often used to give a wider range of tested crimp heights). Additional samples may be required for crimps with multiple wires o
23、f various sizes (See 4.4.4, steps 7 and 8).4.4.4 Procedure1. Pull-out force test shall be performed on leads with the insulation crimp wings open (not crimped).2. Pull-out force test shall be performed on taut leads (i.e., remove slack in cable before performing pull-out test to prevent incorrect te
24、st results due to “jerking”).3. Measure and record the conductor crimp height and width in millimeters for each sample. Refer to Appendix E, 6-8.4. If the insulation crimp is not already open, open it with a de-crimper or other suitable tool so that the pull-out force will reflect only the conductor
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEUSCAR212014PERFORMANCESPECIFICATIONFORCABLETOTERMINALELECTRICALCRIMPSREVISION3PDF

链接地址:http://www.mydoc123.com/p-1028389.html