1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2009 SAE International All rights reserved. No part of this publication ma
3、y be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA)
4、Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSURFACEVEHICLEINFORMATIONREPORTJ2856 SEP2009 Issued 2009-09Superseding EA-23 APR2005 Users Manual for the 50thPercentile Male Hybrid III Dummy RATIONALEThe 1986 version of Engineering Aid 23 focused on differences betw
5、een the Hybrid III and its predecessor, the Hybrid II dummy.The 1998 revision of EA-23 removed the differences between the Hybrid II and Hybrid III, as most users had experience in using the Hybrid III. Instead of presenting two variations on the calibration procedures that were included in the 1986
6、 version, only the currently accepted practice is listed. It included modifications which are based on many years experience with the Hybrid III, and addresses changes incorporated into the dummy. The most significant differences result from some changes in the Hybrid III dummy. One change now calls
7、 for using feet with a 45 degree range of motion rather than 30 degrees; the feet also have a prescribed force-deflection characteristic. The other major change is a redesigned upper femur, which makes the hip joint range of motion more symmetric and biofidelic, and also prevents metal-to-metal cont
8、act between the hip bone and the femur. These part changes require additional procedures to ensure the proper range of motion at the hip joint. SAE J2856 replaced EA-23 in 2009. In addition to the format change and the correction of typographical errors, the following corrections were made to this I
9、nformation Report: References to SAE J211 were changed to SAE J211-1 throughout the report Section 2 REFERENCES was added Section 3.1 corrected the reference to the drawing package from “the updated 1997 engineering drawing package” in EA-23 to “the engineering drawing package dated August 30, 1998”
10、 Section 3.1 corrected the reference to the drawing package from “The latest drawing package for the Hybrid III dummy was issued in 1997” in EA-23 to “The latest drawing package for the Hybrid III dummy was issued in 1998” Section 3.2 added title “HYBRID III 50thPERCENTILE MALE DUMMY INSTRUMENTATION
11、” to Table 1 Section 3.7 corrected inconsistency in terminology from “chest jacket” in EA-23 to “chest flesh” Section 3.7 Figure 12 was replaced to more clearly show the correct orientation of the nodding blocks Section 3.9 changed the disassembly instructions for the sternum from “Detach the bib as
12、sembly after loosening the set screw (Figure 27) on the chest displacement slider arm at the displacement pot” to “Detach the bib assembly. Do not loosen the set screw (Figure 27) because this will invalidate the chest pot calibration of SAE Recommended Practice J2517.”Section 3.13 corrected the ins
13、pection of buttock compression from “apply a 335 N (75 lbf) force to the bottom of the pelvis, parallel to the ground” to “apply a 334 N (75 lbf) force to the bottom of the pelvis, perpendicular to the ground” SAE J2856 Issued SEP2009 Page 2 of 74Section 3.16 changed the assembly instructions for th
14、e pin that holds the optional displacement potentiometer displacement rod to the slider from “tightened reasonably” to “tight”Section 3.17 corrected an error in lumbar cable torque from “1.2 to 1.4 Nm” in EA-23 to “1.1 to 1.4 Nm”Section 3.17 corrected inconsistency in terminology from “chest jacket”
15、 in EA-23 to “chest flesh” Section 3.18 added title “CENTERS OF GRAVITY” to Table 2 Section 3.18 revised headers of Table 2 consistent with SAE format guidelines Section 3.18 corrected Center of Gravity Location for the foot in Table 2 from “2.30” inches along the X-axis in EA-23 to “2.20” inches. T
16、he metric dimension was correct Section 3.18 corrected Center of Gravity Location for the foot in Table 2 from “-52.7” mm and “-2.20” inches along the Z-axis in EA-23 to “-53.3” mm and “-2.10” inches Section 4.1 (A) corrected inconsistency in terminology from “chest skin” in EA-23 to “chest flesh” S
17、ection 4.1 (C) changed from “Torque the two spine cables to 1.1 Nm (10 inlbf)” in EA-23 to “Torque the two lumbar cables to 1.1 to 1.4 Nm (10 to 12 inlbf)” to be consistent with Section 3.17 Section 4.1 (L) corrected inconsistency in terminology from “chest skin” in EA-23 to “chest flesh” Section 4.
18、2 (A) corrected inconsistency in terminology in Table 4 from “Upper Torso Assembly with Torso Jacket” in EA-23 to “Upper Torso Assembly with Chest Flesh” Section 4.2 (A) corrected description of Lower Torso Assembly in Table 4 from “(includes femurs and their lower lumbar adapting plate)” in EA-23 t
19、o “(includes femurs and lower lumbar adapting plate)” Section 4.2 (A) corrected mass of Upper Arm Assembly, Left and Upper Arm Assembly, Right in Table 4 from “4.4 0.1” lb and “2.00 0.05“ kg in EA-23 to “4.4 0.2” lb and “”2.00 0.09” kg in SAE J2856 Section 4.2 (A) corrected terminology in Table 4 fr
20、om “Total Dummy Weight” in EA-23 to “Total Dummy Mass” Section 4.3 (E) 1 changed torque specification for skull cap screws from “18 Nm (160 inlbf)” to “18 Nm minimum (160 inlbf minimum)” Section 4.3 (E) 2 changed environment temperature for head drop test from “18.9 to 25.6 C (66 to 78 F)” to “20.6
21、to 22.2 C (69 to 72 F)” Section 4.4 (E) 3 added title “PENDULUM IMPULSE FOR THE NECK FLEXION TEST” to Table 5 Section 4.4 (F) 3 added title “PENDULUM IMPULSE FOR THE NECK EXTENSION TEST” to Table 6 Section 4.5 (A) corrected inconsistency in terminology from “vest and panty” in EA-23 to “shirt and pa
22、nts” Section 4.5 (B) updated the test probe description to include “the mass of rigid attachments and the lower 1/3 of the suspension cable mass” Section 4.5 (C) changed the filter channel class for the thorax impact test from “Filter all data channels using Channel Class 180 phaseless filters” in E
23、A-23 to “Filter pendulum force using a Channel Class 180 phaseless filter and chest deflection using a Channel Class 600 phaseless filter” for consistency with SAE J211-1 Section 4.5 (D) 1 corrected inconsistency in terminology from “chest skin” in EA-23 to “chest flesh” SAE J2856 Issued SEP2009 Pag
24、e 3 of 74Section 4.5 (D) 1 changed from “Torque the spine cables to 1.2 to 1.4 Nm (10 to 12 inlbf)” in EA-23 to “Torque the two lumbar cables to 1.1 to 1.4 Nm (10 to 12 inlbf)” to be consistent with Section 3.17 Section 4.5 (D) 6 corrected inconsistency in terminology from “chest skin” in EA-23 to “
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ28562009USERSMANUALFORTHE50THPERCENTILEMALEHYBRIDIIIDUMMY 混血 50 百分 男性 假人 用户手册 PDF

链接地址:http://www.mydoc123.com/p-1027650.html