SAE J 2763-2008 Test Procedure for Determining Refrigerant Emissions from Mobile Air Conditioning Systems《移动空气调节系统产生的制冷排放物测定用试验规程》.pdf
《SAE J 2763-2008 Test Procedure for Determining Refrigerant Emissions from Mobile Air Conditioning Systems《移动空气调节系统产生的制冷排放物测定用试验规程》.pdf》由会员分享,可在线阅读,更多相关《SAE J 2763-2008 Test Procedure for Determining Refrigerant Emissions from Mobile Air Conditioning Systems《移动空气调节系统产生的制冷排放物测定用试验规程》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、 SURFACE VEHICLE STANDARD J2763 FEB2015 Issued 2008-08 Reaffirmed 2015-02 Superseding J2763 AUG2008 Test Procedure for Determining Refrigerant Emissions from Mobile Air Conditioning Systems RATIONALE J2763 has been reaffirmed to comply with the SAE five-year review policy. INTRODUCTION Vehicle maker
2、s and A/C system and component suppliers are continually improving the containment of system refrigerant. For development purposes, a common means of measuring refrigerant emissions was deemed desirable; this standard test method is intended to serve that purpose. For commonality with existing vehic
3、le testing, the testing takes place in a chamber (mini-shed) under a static temperature profile and under the California Air Resources Boards Title 13 ambient profile (CARB Profile). 1. SCOPE This SAE Standard covers the Mini-Shed testing methodology to measure the rate of refrigerant loss from an a
4、utomotive air conditioning (A/C) system. This SAE procedure encompasses both front and rear air conditioning systems utilizing refrigerants operating under sub-critical conditions. 1.1 Purpose The purpose of the SAE Mini-Shed Test Refrigerant Emission procedure is to provide a means of measuring ref
5、rigerant emissions from properly assembled vehicle air conditioning systems under specific A/C usage conditions (i.e., typical use conditions) and to convert the results to an estimated annual refrigerant emission rate (g/yr). Such conversion from laboratory test results to estimated vehicle emissio
6、n applies to properly assembled systems and does not account for normal production assembly variations. _ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and i
7、ts applicability and suitability for any particular use, including any patent infringement arising therefrom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your w
8、ritten comments and suggestions. Copyright 2015 SAE International All rights reserved. No part of this publication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written per
9、mission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-4970 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.o
10、rg/technical/standards/J2763_201502 SAE INTERNATIONAL J2763 Reaffirmed FEB2015 Page 2 of 12 2. REFERENCES 2.1 Applicable Publications The following publications form a part of this specification to the extent specified herein. Unless otherwise indicated, the latest version of SAE publications shall
11、apply. 2.1.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org. SAE J2727 HFC-134a Mobile Air Conditioning System Refrigerant Emission Chart 2.1.2 Other Publicatio
12、ns European Emission Regulation Number 706/2007 of 21 June 2007 California Air Resources Boards Title 13 Ambient Profile Armines, Dr. Denis Clodic, Ecole Des Mines (Paris): “Research Study on the Definition of the Implementation of a Method of Measurement of Annual Leak Flow Rates (LFRs) of MAC Syst
13、ems” 3. TEST PROCEDURE 3.1 System Assembly 3.1.1 Starting with components that have never been exposed to refrigerant, assemble the A/C system on the test fixture per system schematic. Do not charge the system with refrigerant. 3.1.2 Tighten each fitting to its specified minimum torque. 3.1.3 Make a
14、ll electrical connections and pressure connections. 3.1.4 Place test fixture in the Emission Test Chamber (Volume of 1 cubic meter). 3.1.5 The Emission Test Chamber (Mini-Shed) should be equipped with an expansion bag to assure isobaric conditions throughout the test. Changes in temperature cause co
15、rresponding changes in pressure (which can cause leakage from the chamber), or in volume (which slightly affect ppm/vol readings). Slight variations in volume are preferred over mass loss from the chamber during testing. Readings taken at calibration temperature should not be affected. 3.1.6 Larger
16、chambers may be required for large A/C systems and will require proportionately larger volumetric injections of refrigerant during the calibration procedure (below). 3.2 Chamber Calibration 3.2.1 Refrigerant vapor injected in this procedure is to be accomplished at known and recorded atmospheric pre
17、ssure and temperature for subsequent conversion to mass injected. 3.2.1.1 Record atmospheric pressure. 3.2.2 Refrigerant concentration measurements (ppm by volume readings) should be taken every 2 minutes. If the equipment has a longer response time, measurements should be taken at the shortest meas
18、urement interval possible. SAE INTERNATIONAL J2763 Reaffirmed FEB2015 Page 3 of 12 3.2.3 To verify chamber integrity, inject 100 cc of refrigerant per cubic meter chamber volume and record ppm measurement for 24 hr. Readings shall vary no more than 5% after initial stabilization. 3.2.4 The following
19、 procedure is intended to enable construction of a calibration curve covering the full range of expected refrigerant emission to be measured. 3.2.5 Purge the chamber with fans. Flush the gas analyzer lines with dry nitrogen to remove any residual water vapor and refrigerant from the line sets. 3.2.6
20、 Close the chamber and record refrigerant ppm. If above 5 ppm of refrigerant, open chamber, start fans to purge chamber. Close chamber and re-measure ppm. Repeat as necessary until the level drops below 5 ppm. 3.2.7 Stabilize the system at 20 C 2 C chamber temperature for 1 hr, recording emissions.
21、Record initial chamber concentration (ppm) for 10 minutes. ppm readings should vary less than 10%. If greater, check for refrigerant intrusion from outside the chamber or equipment malfunction. 3.2.8 Record initial chamber ppm and then, with a gas-tight syringe, inject 5.0 cc of pure refrigerant vap
22、or into chamber and record refrigerant concentration for at least 10 minutes. Last 2 readings must be within 10% of each other. If greater, check for refrigerant intrusion from outside the chamber or equipment malfunction. Open chamber, start fans to purge chamber. Close chamber and re-measure ppm.
23、Repeat as necessary until the level drops below 5 ppm. 3.2.9 Repeat 3.2.8, injecting 10.0 cc of pure refrigerant vapor. 3.2.10 Repeat 3.2.8, injecting 20.0 cc of pure refrigerant vapor. 3.2.11 Repeat 3.2.8, injecting 30.0 cc of pure refrigerant vapor. 3.2.12 Repeat 3.2.8, injecting 40.0 cc of pure r
24、efrigerant vapor. 3.2.13 Continue additions as necessary to construct calibration curves covering the expected range of test chamber concentrations. 3.3 Calibration Curves 3.3.1 Calculate the net change in refrigerant emission concentration (c) for each injection. c = final concentration initial con
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ27632008TESTPROCEDUREFORDETERMININGREFRIGERANTEMISSIONSFROMMOBILEAIRCONDITIONINGSYSTEMS 移动 空气调节 系统

链接地址:http://www.mydoc123.com/p-1027575.html