SAE J 2742-2013 Combination 11 Conductors and 4 Pairs ECBS Cable《11根导线和4对ECBS电缆组合》.pdf
《SAE J 2742-2013 Combination 11 Conductors and 4 Pairs ECBS Cable《11根导线和4对ECBS电缆组合》.pdf》由会员分享,可在线阅读,更多相关《SAE J 2742-2013 Combination 11 Conductors and 4 Pairs ECBS Cable《11根导线和4对ECBS电缆组合》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be revised, reaffirmed, stabilized, or cancelled. SAE invites your written comments and suggestions. Copyright 2013 SAE International All rights reserved. No part of this p
3、ublication may be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: +1 724-776-497
4、0 (outside USA) Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org SAE values your input. To provide feedback on this Technical Report, please visit http:/www.sae.org/technical/standards/J2742_201304 SURFACE VEHICLE STANDARD J2742 APR2013 Issued 2013-04 Combination 11
5、 Conductors and 4 Pairs ECBS Cable RATIONALE This document has been developed concurrently with the SAE J2691 “15 Pole Connector Between Towing Vehicles and Trailers with 12 volt Nominal Supply” Standard. The cable and connectors provide the system for conveying power, ground and signal to support t
6、he trailer ECBS (Electronically Controlled Braking System) and anticipated, mid-term future requirements. In addition the system will meet all the requirements of the SAE J2394/J560 system since the new cable must be compatible with non-ECBS trailers. The system is being designed with improved perfo
7、rmance characteristics, both environmental and electrical, when compared to the 7-circuit system. As the truck trailer industry moves towards more advanced electronic systems, the connector in this standard would become more and more dominant. Over a period of time, the SAE J560 connector would no l
8、onger be used and the connector in this standard would be the single connector interfacing towing and towed ECBS equipped vehicles. 1. SCOPE This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and 4 twisted pairs for
9、 use on trucks, trailers, and dollies in conjunction with SAEJ2691. (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity. 2.
10、REFERENCES 2.1 Applicable Documents The following publications form a part of this specification to the extent specified herein. Unless otherwise indicated, the latest issue of SAE publications shall apply. SAE J2742 Issued APR2013 Page 2 of 112.1.1 SAE Publications Available from SAE International,
11、 400 Commonwealth Drive, Warrendale, PA 15096-0001 0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org. SAE J560 Seven Conductor Electrical Connector for Truck-Trailer Jumper Cable SAE J1128 Low Tension Primary Cable SAE J1939-15 Reduced Physical Layer 250K bit
12、s/sec, UN-Shielded Twisted Pair (UTP) SAE J2394 Seven Conductor Cable for ABS Power - Truck and Bus SAE J2691 15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply - Truck and Bus 2.1.2 ASTM Publications Available from ASTM International, 100 Barr Harbor Drive, P.O. Box
13、C700, West Conshohocken, PA 19428-2959, Tel: 610-832-9585, www.astm.org. ASTM B 3 Specification for Soft or Annealed Copper Wire ASTM B 33 Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes ASTM B 117 Method of Salt Spray (Fog) Testing ASTM B 172 Specification for Rope Lay
14、 Stranded Copper Conductors Having Bunch-Stranded Members for Electrical Conductors ASTM B 174 Specification for Bunch-Stranded Copper Conductors for Electrical Conductors ASTM B 263 Standard Test Method for Determination of Cross-Sectional Area of Standard Conductors ASTM D 412 Standard Test Method
15、s for Vulcanized Rubber and Thermoplastic Rubbers and Thermoplastic Elastomers - Tension ASTM D 573 Standard Test Method for Rubber-Deterioration in an Air Oven ASTM D 4060 Standard Test Method for Abrasion Resistance of Organic Coatings. ASTM E 145 Standard Specification for Gravity-Convection and
16、Forced-Ventilation Ovens 2.1.3 UL (UNDERWRITERS LABORATORY) Publications Available from Underwriters Laboratories Inc., 333 Pfingsten Road, Northbrook, IL 60062-2096, Tel: 847-272-8800, . UL 1581 Reference Standard for Electrical Wires, Cables, and Flexible Cords-Section 593. 2.2 Related Publication
17、s The following publications are provided for information purposes only and are not a required part of this SAE Technical Report. SAE J2742 Issued APR2013 Page 3 of 112.2.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001 0001, Tel: 877-606-7323 (i
18、nside USA and Canada) or 724-776-4970 (outside USA), www.sae.org. SAE J1939 Recommended Practice for a Serial Control and Communications Vehicle Network SAE J2174 Heavy-Duty Wiring Systems for Trailers 2032 mm or More in Width SAE J2202 Heavy-Duty Wiring Systems for On-Highway Trucks SAE J2222 Coile
19、d Electrical Cable - Truck and Bus 2.2.2 ISO Publications Available from American National Standards Institute, 25 West 43rd Street, New York, NY 10036-8002, Tel: 212-642-4900, www.ansi.org. ISO 4141-1,2,3,4 Multi-Core Connecting Cables (Parts 1 through 4) 3. TERMS AND DEFINITIONS 3.1 FLEXING Descri
20、bes a condition where the cable is installed in an unsupported way over a distance of greater than 0.5 m (18 in) and/or where there is a reasonable likelihood that the cable will be subjected to bending, longitudinal extension, or significant movement. As an example all cables connecting the tractor
21、 to trailer or dolly to trailer are to be considered flexing cables. 3.2 STATIONARY Describes a condition where the cable is installed in a fashion where its weight is supported within a distance of 0.5 m (18 in) or less, and where there is little likelihood of flexing as described above. An example
22、 of a stationary application is cable that is connected with clamps to a trailer chassis. 3.3 CONDUCTOR The current carrying element(s) in a cable comprised of a series of copper strands twisted together. 3.4 STRAND The solid component members of a conductor. 3.5 LAY The measure along a single plane
23、, between an individual strand or series of copper strands or insulated conductors starting and ending points in a complete spiral wrap around the grouping of which it is a part. 3.6 INSULATION The material applied to the conductor to provide electrical insulation and a level of mechanical protectio
24、n. 3.7 CABLE CORE The grouping of insulated conductors twisted together. SAE J2742 Issued APR2013 Page 4 of 113.8 JACKET The outer sheath applied to the cable core to maintain inner conductor positioning and to enhance the mechanical strength and durability of the cable. 4. TYPES Due to the variatio
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ27422013COMBINATION11CONDUCTORSAND4PAIRSECBSCABLE11 导线 ECBS 电缆 组合 PDF

链接地址:http://www.mydoc123.com/p-1027560.html