SAE J 2560-2007 Forward Lighting Halogen Bulb Performance Requirements for Motor Vehicles《摩托车前照明卤素灯泡性能要求》.pdf
《SAE J 2560-2007 Forward Lighting Halogen Bulb Performance Requirements for Motor Vehicles《摩托车前照明卤素灯泡性能要求》.pdf》由会员分享,可在线阅读,更多相关《SAE J 2560-2007 Forward Lighting Halogen Bulb Performance Requirements for Motor Vehicles《摩托车前照明卤素灯泡性能要求》.pdf(71页珍藏版)》请在麦多课文档分享上搜索。
1、_ SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising there
2、from, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2007 SAE International All rights reserved. No part of this publication m
3、ay be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA)
4、 Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.org J2560 ISSUED JUL2007 SURFACE VEHICLE RECOMMENDED PRACTICE Issued 2007-07 Forward Lighting Halogen Bulb Performance Requirements for Motor Vehicles RATIONALE Proposed SAE J2560 Modified Sections of J1383: a. SAE J2560
5、 has been created as a result of rewriting SAE J1383. The intent is to remove all forward lighting halogen bulb information from SAE J1383 and place it in this new SAE J2560 document. b. Removed all text, figures and tables from J1383 that do not apply to forward lighting halogen bulbs. Ref. Text Se
6、ctions 3.1, 3.2 , 3.4-3.7, 3.12-3.17, 3.19. 3.20, 3.26, 3.27, 4.3-4.6, 5.1, 5.3, 5.4, 5.8-5.12, 5.15-5.19, 6.1, 6.2, 6.4, 6.5, 6.9-6.13, 6.16-6.22, 7.1, 7.2, 7.4 items a, b, d, 7.6, 7.7 Ref. Figures 1, 3-8, 11-18, 20-32 Ref. Tables 3-9 c. Revised numerical order of definitions, identification code d
7、esignation, tests, performance requirements and guidelines. d. Re-numbered figures and tables to provide continuity to this new document. e. A new color test (Section 5.3) and Color Requirements (Section 6.3) are added, including Figures 3 and 4. The color test is based on the Global Working Group o
8、n the Investigation into the Effects of Absorptive and Interference Coatings Applied on Replaceable Headlamp Bulbs. f. In the color test (Section 5.3) Section 5.3.1.5 requires the test of the high beam (major) filament for double filament bulbs due to the shield in H4/HB2, which partly obscures the
9、low beam (minor) filament. g. Added Vibration Test from IEC (Section 5.8) h. Added the Daytime Running Lamp Luminous Flux Maintenance Guideline and Life Durability Guideline verbatim from SAE J2087, as the SAE J2087 standard removed this guideline in the latest revision. i. In cases where bulb dimen
10、sions are elsewhere documented, such as in 49CFR564 docket 98-3397, ECE R37, and/or IEC (IEC-60809, IEC-60061-1, and IEC-60061) bulb drawings were not duplicated to avoid showing discrepancies between the standards. Therefore this document contains no figures of bulbs H1, H3, H7, but references to t
11、he applicable standards. SAE J2560 Issued JUL2007 - 2 - j. Revision history of the figures: Figures 9, 11, 19, 20, 27, 30, 31, 33, and 40 were copied from J1383 and remain unchanged Figures 1, 2, 5, 6, 13, 14, 16, 18, 21, 24, 26, 28, 34, 36, 37, 38, and 39 were redrawn but remain unchanged Figures 3
12、, 4 and 10 are new Figures 7, 8, 12, 17, and 25 had tolerances on dimensions updated to reflect the same as in Part 564 docket Figures 17 and 25 had dimensions KH and EH, respectively updated to reflect the same as in Part 564 docket Figures 15 and 23: The connector cover was marked as optional. The
13、 luminous flux test can be more accurately carried out by measuring and compensating for the absorption of the test bulb and its base Figures 14 and 22: footnote 11 was copied from updated Part 564 docket submissions Figure 29: dimension AT was updated according to the Part 564 docket submission Fig
14、ure 32: “blending radii permitted” was added from the Part 564 docket submission Figures 35 and 37: HB2 tolerances were added TABLE OF CONTENTS 1. SCOPE 4 2. REFERENCES 4 2.1 Applicable Publications . 4 2.1.1 SAE Publications. 4 2.1.2 Federal Publications . 4 2.1.3 International Electrotechnical Com
15、mission (IEC) Publications. 5 2.1.4 IESNA Publications. 5 2.1.5 CIE Publications 5 2.2 Related Publications . 5 2.2.1 CIE Publications 5 2.2.2 ECE Regulation. 5 3. DEFINITIONS . 6 3.1 Forward Lighting . 6 3.2 Replaceable Bulb (Bulb) . 6 3.3 Seasoning . 6 3.4 Design Voltage 6 3.5 Life. 6 3.6 Life Tes
16、t Voltage . 6 3.7 Test Voltage 6 3.8 Rated Voltage . 6 3.9 Accurate Rated Bulb (Standard Bulb). 6 3.10 High Beam 7 3.11 Low Beam . 7 3.12 High Beam Filament 7 3.13 Low Beam Filament 7 3.14 Filament Distortion 8 3.15 Rated Average Lab Life 8 3.16 Design Life 8 3.17 Gauging Standard. 8 4. IDENTIFICATI
17、ON CODE DESIGNATION 10 4.1 SAE J759 Lighting Identification Code . 10 4.2 Replaceable Bulb Marking Requirements 10 5. TESTS. 10 5.1 Deflection Test 10 5.1.1 Bulb Mounting . 10 5.1.2 Force Definition. 10 5.1.3 Test Angles . 10 5.2 Seal Test . 10 SAE J2560 Issued JUL2007 - 3 - 5.2.1 Bulb Fixturing 10
18、5.2.2 Test Description 10 5.2.3 Test Duration. 10 5.3 Color Test 11 5.3.1 Preparation 11 5.3.2 Color Measurement 11 5.4 Power (Wattage) Test . 12 5.4.1 Test Voltage 12 5.4.2 Seasoning . 12 5.5 Luminous Flux Test. 12 5.5.1 Seasoning . 12 5.5.2 Photometry 12 5.5.3 Test Definition . 12 5.6 Luminous Flu
19、x Maintenance Test. 12 5.6.1 Luminous Flux Measurement 12 5.6.2 Mounting . 12 5.6.3 Test Voltage 12 5.6.4 Measurement 12 5.7 Filament Rated Average Lab Life Test . 13 5.7.1 Test Set Up . 13 5.7.2 Bulb Energizing. 13 5.7.3 Filament subject to Test 13 5.7.4 Test Termination Condition. 13 5.8 Vibration
20、 Test 13 6. PERFORMANCE REQUIREMENTS 13 6.1 Deflection Requirement 13 6.2 Seal Requirement . 13 6.3 Color Requirement (SAE J578) 14 6.4 Power (Wattage) Requirement . 14 6.5 Luminous Flux Requirement. 14 6.6 Maintenance of Luminous Flux Requirement . 14 6.7 Design Requirements . 14 6.7.1 Bulb Dimensi
21、onal Interchangeability Requirements . 14 6.7.2 Accurate Rated Bulbs (Standard Bulbs). 14 6.7.3 Bulb Specifications 14 6.8 Vibration Requirements 14 7. GUIDELINES 15 7.1 Replaceable Bulb Filament End Coil Definition 15 7.2 Dimensional Guidelines 15 7.3 Filament Rated Average Lab Life Guideline. 15 7
22、.4 Daytime Running Lamp Bulb Luminous Flux Maintenance Guideline and Life Durability Guideline . 15 7.4.1 Double Filament Bulbs High Beam DRL 16 7.4.2 Double Filament Bulb Low Beam DRL 17 7.4.3 Single Filament Bulb . 18 7.4.4 Additional DRL Guidelines 18 8. REPLACEABLE BULB FILAMENT DIMENSIONS AND L
23、OCATION TESTS 18 8.1 9004 Replaceable Bulb. 18 8.1.1 Low Beam Filament Location Test 19 8.1.2 High Beam Filament Location Test. 19 8.1.3 Low Beam Filament Location 19 8.1.4 High Beam Filament Location. 19 8.2 9005 and 9006 Replaceable Bulb. 20 8.2.1 High Beam Filament Location test 20 8.2.2 Low Beam
24、 Filament Location Test 20 SAE J2560 Issued JUL2007 - 4 - 8.2.3 High Beam Filament Location. 20 8.2.4 Low Beam Filament Location 21 8.2.5 Viewing Direction for the HB3(9005) and HB4(9006). 21 8.3 Bulb Filament Dimension and Location Test for the 9007 Replaceable Bulb 21 8.3.1 Low Beam Filament Locat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ25602007FORWARDLIGHTINGHALOGENBULBPERFORMANCEREQUIREMENTSFORMOTORVEHICLES 摩托 车前 照明 卤素 灯泡 性能 要求 PDF

链接地址:http://www.mydoc123.com/p-1027428.html