SAE J 2470-2009 Hydraulic Fluid Power Valves Method for Assessing the Lock Sensitivity to Contaminants《评定液压阀对锁定污染物敏感性的方法》.pdf
《SAE J 2470-2009 Hydraulic Fluid Power Valves Method for Assessing the Lock Sensitivity to Contaminants《评定液压阀对锁定污染物敏感性的方法》.pdf》由会员分享,可在线阅读,更多相关《SAE J 2470-2009 Hydraulic Fluid Power Valves Method for Assessing the Lock Sensitivity to Contaminants《评定液压阀对锁定污染物敏感性的方法》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、_SAE Technical Standards Board Rules provide that: “This report is published by SAE to advance the state of technical and engineering sciences. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringement arising theref
2、rom, is the sole responsibility of the user.” SAE reviews each technical report at least every five years at which time it may be reaffirmed, revised, or cancelled. SAE invites your written comments and suggestions. Copyright 2009 SAE International All rights reserved. No part of this publication ma
3、y be reproduced, stored in a retrieval system or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAE. TO PLACE A DOCUMENT ORDER: Tel: 877-606-7323 (inside USA and Canada) Tel: 724-776-4970 (outside USA)
4、Fax: 724-776-0790 Email: CustomerServicesae.org SAE WEB ADDRESS: http:/www.sae.orgSURFACEVEHICLERECOMMENDEDPRACTICEJ2470 JAN2009 Issued 1999-10Revised 2009-01 Superseding J2470 NOV2006 Hydraulic Fluid PowerValvesMethod for Assessing the Lock Sensitivity to Contaminants RATIONALEThe primary reasons f
5、or this revision are to identify current sources for the carbonyl iron contaminant and to update the requirements to reflect the currently available carbonyl iron contaminants. The sources of all test contaminants and the listing of laboratories with capability to conduct the test have also been upd
6、ated. FOREWORDNOTE: Some Test Procedures are potentially dangerous. SAE Technical Reports do not purport to address all of the safety problems, if any, associated with their use. It is the responsibility of the user of an SAE Technical Report to establish and employ appropriate safety practices. Onl
7、y individuals who have been properly trained in the test procedure and who are aware of any hazards that may be present should conduct the tests. Appropriate safety and health precautions must be employed when conducting any test. 1. SCOPE 1.1 This SAE Recommended Practice defines a procedure, which
8、 will aid in assessing the contaminant sensitivity of hydraulic valves. The approach taken defines a test procedure with flexibility for testing valves in a wide range of contamination levels. The user of this procedure must establish the contamination levels for testing. Three levels are suggested
9、which should cover the range for most valve applications. This procedure does not establish the contaminant sensitivity requirements for any valve. The user of this procedure needs to be aware of the system contamination level that the valve will operate in and select test contamination levels signi
10、ficantly higher than the operating level to assess the suitability of the valve. The test procedure permits a valve to be tested without disassembly and therefore permits protection of proprietary design information. 1.2 This procedure assesses the contamination sensitivity of valves by contaminant
11、lock. The procedure indicates the sensitivity of valves by contaminant lock due to various sizes of contaminants. The test is designed to assess the contaminant sensitivity of valves in tests of relatively short duration. See Appendix A for guidance as to how the tests and their results may be used.
12、 1.3 The tests are purposely designed to be severe in order to be applicable to a wide range of contaminated environments. The use of valves in many applications and for various purposes results in differing levels of acceptable performance. That is, the same valve may be unacceptable in relation to
13、 operation in a contaminated environment in one application and be acceptable in another. The user must make that decision based on a review of the expected level of the specific application and the test results obtained. NOTE: See 7.2 if document is to be contractually invoked. SAE J2470 Revised JA
14、N2009 Page 2 of 132. REFERENCES 2.1 Applicable Publications The following documents form a part of this specification to the extent specified herein. Unless otherwise indicated, the latest issue of the documents shall be used except in those cases where an invitation for bid or procurement contract
15、specifically identifies the issues in effect on a particular date.2.1.1 SAE Publications Available from SAE International, 400 Commonwealth Drive, Warrendale, PA 15096-0001, Tel: 877-606-7323 (inside USA and Canada) or 724-776-4970 (outside USA), www.sae.org.SAE ARP490 Electrohydraulic Servovalves S
16、AE ARP785 AerospaceProcedure for the Determination of Particulate Contamination in Hydraulic Fluids by the Control Filter Gravimetric Procedure 2.1.2 ISO Publications Publisher: International Organization for Standardization, 1 rue de Varembe, CH-1211 Geneva 20, Switzerland. Available from American
17、National Standards Institute (ANSI) www.ansi.org or from the National Fluid Power Association (NFPA) .ISO 1219-1 Graphic symbols for conventional use and data-processing applications ISO 4021 Hydraulic fluid powerParticulate contamination analysisExtraction of fluid samples from lines of an operatin
18、g system ISO 4405 Hydraulic fluid powerFluid contaminationDetermination of particulate contamination by the gravimetric method ISO 4406 Hydraulic fluid powerMethod for coding the level of contamination by solid particles ISO 5598 Fluid power systems and componentsVocabulary ISO 6403 Hydraulic fluid
19、powerValves controlling flow and pressureTest methods ISO 10770-1 Hydraulic fluid powerElectrically modulated hydraulic control valvesPart 1: Test methods for four-way directional flow control valves ISO 10770-2 Hydraulic fluid powerElectrically modulated hydraulic control valvesPart 2: Test methods
20、 for three-way directional flow control valves ISO 11500 Hydraulic fluid powerDetermination of the particulate contamination level of a liquid sample by automatic particle counting using the light-extinction principle ISO 12103-1 Road vehiclesTest dust for filter evaluationPart 1: Arizona test dust
21、ISO 16889 Hydraulic fluid powerFiltersMulti-pass method for evaluating filtration performance of a filter element SAE J2470 Revised JAN2009 Page 3 of 133. DEFINITIONS For definitions of other terms, see ISO 5598. 3.1 Contaminant Lock/Silt Lock The process of restricting movement by contaminant build
22、up between two surfaces which move in relation to each other, such as spool/bore or spool/sleeve assemblies. 3.2 Contaminant Sensitivity The change in valve performance caused by particulate contaminants in the fluid. 4. TEST REQUIREMENTS 4.1 Test Equipment 4.1.1 The test system shall consist of a h
23、ydraulic test circuit, as illustrated in Figure 1, comprising of a reservoir, a pumping unit, an injection system, a heat exchanger, a flow-meter, pressure gauges, a temperature indicator, a relief valve, a control valve, and cleanup control filters. Select components for the test circuit that are o
24、f a design known to function satisfactorily with contaminated fluid. 4.1.2 Construct the reservoir with a conical bottom having an included angle of less than 90 degrees to ensure sufficient fluid agitation. Diffuse the hydraulic fluid entering the reservoir below the surface of the fluid. 4.1.3 Con
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- SAEJ24702009HYDRAULICFLUIDPOWERVALVESMETHODFORASSESSINGTHELOCKSENSITIVITYTOCONTAMINANTS 评定 液压 锁定 污染物

链接地址:http://www.mydoc123.com/p-1027369.html